Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
- Product Code
- 100983
- Chemical Name
- Ethanol
Regulatory Identifiers
- CAS Number
- 64-17-5 Check regulations →
Identified Uses
Reagent for analysis, Chemical production
Manufacturers & Suppliers
EMD Millipore Corporation
manufacturer
400 Summit Drive BURLINGTON MA 01803 UNITED STATES
+1 800-645-5476
Emergency Contacts
CHEMTREC
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol EC: 200-578-6 | 64-17-5 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides. Combustible. Pay attention to flashback. Vapors are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
Remove container from danger zone and cool with water.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE®
CAS: 64-17-5
Methanol for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-56-1
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
Ethanol absolute for analysis EMPARTA® ACS
CAS: 64-17-5
Isoamyl alcohol for analysis EMSURE® ACS,Reag. Ph Eur
CAS: 123-51-3
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge. Change contaminated clothing. Wash hands after working with substance.
Keep container tightly closed in a dry and well-ventilated place. Recommended storage temperature see product label.
Change contaminated clothing. Wash hands after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: butyl-rubber Minimum layer thickness: 0.7 mm Break through time: 480 min Material tested: Butoject® (KCL 898) Splash contact Material: Nitrile rubber Minimum layer thickness: 0.4 mm Break through time: 120 min Material tested: Camatril® (KCL 730 / Aldrich Z677442, Size M)
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapors may form explosive mixture with air.
Risk of explosion/exothermic reaction with: hydrogen peroxide, perchlorates, perchloric acid, Nitric acid, mercury(II) nitrate, permanganic acid, Nitriles, peroxi compounds, Strong oxidizing agents, nitrosyl compounds, Peroxides, sodium, Potassium, halogen oxides, calcium hypochlorite, nitrogen dioxide, metallic oxides, uranium hexafluoride, iodides, Chlorine, Alkali metals, Alkaline earth metals, alkali oxides, Ethylene oxide, silver, with Nitric acid, silver compounds, with Ammonia, potassium permanganate, with conc. sulfuric acid. Risk of ignition or formation of inflammable gases or vapours with: halogen-halogen compounds, chromium(VI) oxide, chromyl chloride, Fluorine, hydrides, Oxides of phosphorus, platinum, Nitric acid, with potassium permanganate.
Warming.
rubber, various plastics
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1170
- Shipping Name
- Ethanol
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The signal word is danger.
What is the physical form of Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a liquid appearing as colorless with colorless color. It has pungent odor.
What is Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?
Reagent for analysis, Chemical production
What are the hazard statements for Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapor.
- H319: Causes serious eye irritation.
What is the melting point of Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The melting point is -144.0 °C (-227.2 °F) at 1,013.25 hPa and the boiling point is 78.29 °C 172.92 °F at 1,013 hPa.