NextSDS Logo
Safety Data Sheet EN

DNA/RNA-ExitusPlus™

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DNA/RNA-ExitusPlus™
Product Code
A7089

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

A

AppliChem GmbH

manufacturer

Ottoweg 4, D-64291 Darmstadt

+49 (0)6151 93570

Emergency Contacts

Emergency Contact

+49(0)6151 93570

Mo-Th 08:00 - 17:00 h; Fr 08:00 - 14:30 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Carc. Cat. 1A H350

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H350 May cause cancer.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

aqueous solution

Chemical Name CAS Number Concentration Hazardous
ethanol 64-17-5 4 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. Seek medical treatment in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Seek medical treatment in case of complaints.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

In case of fire, the following can be released: Carbon monoxide and carbon dioxide, Sulfur oxides (SOx). Non-combustible.

Instructions

Contain escaping vapours with water.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid substance contact. Do not inhale steams/aerosols.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Clean up affected area.

Materials: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

Protect from exposure to the light. Keep container sealed.

Fire prevention

The product is not flammable.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Additional information about design of technical systems: No further data; see section 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Value for the permeation: Level ≥ 480 min. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Value for the permeation: Level ≥ 480 min.

Eyes

Safety glasses

Respiratory

Use suitable respiratory protective device only when aerosol or mist is formed.

Skin/Body

Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Fluid
Colour
Various colors
Colour Intensity
---
Form
Fluid
Odor
Alcohol-like
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
Undetermined.
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
Not determined.
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
425 °C (797 °F)
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
5.00 % / 761.0 g/l / 6.35 lb/gal
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

In the event of fire: See chapter 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available.

12.2 Persistence and degradability

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

12.6 Endocrine disrupting properties

Not available.

12.7 Other adverse effects

No further relevant information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Chemicals must be disposed of in compliance with the respective national regulations.

Disposal

Must not be disposed of together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DNA/RNA-ExitusPlus™?

The signal word is danger.

What is the physical form of DNA/RNA-ExitusPlus™?

DNA/RNA-ExitusPlus™ is a liquid appearing as fluid with various colors color. It has alcohol-like odor.

What is DNA/RNA-ExitusPlus™ used for?

Laboratory chemicals

What are the hazard statements for DNA/RNA-ExitusPlus™?

This substance has 1 hazard statement:

  • H350: May cause cancer.

What is the melting point of DNA/RNA-ExitusPlus™?

The melting point is Undetermined. and the boiling point is Undetermined..