Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DNA/RNA-ExitusPlus™
- Product Code
- A7089
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Manufacturers & Suppliers
AppliChem GmbH
manufacturer
Ottoweg 4, D-64291 Darmstadt
+49 (0)6151 93570
Emergency Contacts
Emergency Contact
+49(0)6151 93570
Mo-Th 08:00 - 17:00 h; Fr 08:00 - 14:30 h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
aqueous solution
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol | 64-17-5 | 4 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. Seek medical treatment in case of complaints.
Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Seek medical treatment in case of complaints.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
In case of fire, the following can be released: Carbon monoxide and carbon dioxide, Sulfur oxides (SOx). Non-combustible.
Contain escaping vapours with water.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid substance contact. Do not inhale steams/aerosols.
Do not allow to enter sewers/ surface or ground water.
Clean up affected area.
Materials: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Related Products
Similar products with comparable safety profiles
DNA/RNA-ExitusPlus™ IF
---
NucleoSpin DNA RapidLyse (50)
UFI: TTWV-43C9-R202-NTGN, D0HW-E3PF-P200-V61A, GXGW-X302-C20G-6UF8
RNasin® Plus RNase Inhibitor
---
Quant-iT™ dsDNABRreagent
---
NucleoSpin RNA (50)
---
2x RNA Loading Dye
---
NucleoSpin DNA Insect (50)
UFI: TTWV-43C9-R202-NTGN, RV7W-C33R-J20Y-1RP6, MMPT-631A-V206-GNTN
Quant-iT™ dsDNABRbuffer
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special precautions are necessary if used correctly.
Protect from exposure to the light. Keep container sealed.
The product is not flammable.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Additional information about design of technical systems: No further data; see section 7.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Value for the permeation: Level ≥ 480 min. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Value for the permeation: Level ≥ 480 min.
Safety glasses
Use suitable respiratory protective device only when aerosol or mist is formed.
Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
In the event of fire: See chapter 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No further relevant information available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemicals must be disposed of in compliance with the respective national regulations.
Must not be disposed of together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DNA/RNA-ExitusPlus™?
The signal word is danger.
What is the physical form of DNA/RNA-ExitusPlus™?
DNA/RNA-ExitusPlus™ is a liquid appearing as fluid with various colors color. It has alcohol-like odor.
What is DNA/RNA-ExitusPlus™ used for?
Laboratory chemicals
What are the hazard statements for DNA/RNA-ExitusPlus™?
This substance has 1 hazard statement:
- H350: May cause cancer.
What is the melting point of DNA/RNA-ExitusPlus™?
The melting point is Undetermined. and the boiling point is Undetermined..