Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PROCOLD T2
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Heat transfer fluid, Coolant
Uses advised against
No additional information available
Manufacturers & Suppliers
ARCANE INDUSTRIES
manufacturer
73 AVENUE DU DOUARD, ZI LES PALUDS, 13685 AUBAGNE - FRANCE
+33 (0)4 42 82 16 95
Emergency Contacts
Numéro ORFILA (INRS) FRANCE
+33 (0)1 45 42 59 59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanediol, ethylene glycol EC: 203-473-3 | 107-21-1 | 25 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air in case of accidental inhalation.
Remove clothing and rinse skin with water.
Rinse immediately and plentifully with water, also under the eyelids, for at least 20 minutes. Obtain medical attention if pain, blinking or redness persist.
Rinse mouth. Do NOT induce vomiting. Immediately call a POISON CENTER or doctor/physician.
Immediate Medical Attention
Immediately call a POISON CENTER or doctor/physician. Obtain medical attention if pain, blinking or redness persist.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Sand. Water spray.
Do not use a heavy water stream.
Combustion produces toxic gases.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire-fighting water from entering environment.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area. Stop release. Stop leak if safe to do so.
Do not allow uncontrolled discharge of product into the environment.
Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage.
Materials: inert solids, such as clay or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not handle until all safety precautions have been read and understood. Ensure good ventilation of the work station.
Keep in a cool, well-ventilated place. Keep container closed when not in use. Hygroscopic product.
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Keep away from any flames or sparking source.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation.
Gloves.
Safety glasses.
Wear suitable protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No additional information available
Stable under use and storage conditions as recommended in section 7.
No additional information available
No additional information available
Strong acids, strong bases and oxidation agents.
fume. Carbon monoxide. Carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PROCOLD T2?
The signal word is warning.
What is the physical form of PROCOLD T2?
PROCOLD T2 is a liquid appearing as clear. with blue. color. It has slight. odor.
What is the solubility of PROCOLD T2?
Miscible with water.
What is PROCOLD T2 used for?
Heat transfer fluid, Coolant
What are the hazard statements for PROCOLD T2?
This substance has 2 hazard statements:
- H302: Harmful if swallowed
- H373: May cause damage to organs (kidneys) through prolonged or repeated exposure
What is the melting point of PROCOLD T2?
The melting point is No data available and the boiling point is 100 - 197 °C.