NextSDS Logo
Safety Data Sheet EN

Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®

CAS 17372-87-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®
Product Code
115935

Regulatory Identifiers

CAS Number
17372-87-1 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

In vitro diagnostic reagent, Reagent for analysis

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P260 Do not breathe dust.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Eosin G EC: 241-409-6 17372-87-1 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water.

Ingestion

immediately make victim drink water (two glasses at most).

Immediate Medical Attention

Call in ophthalmologist. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Carbon dioxide (CO2), Foam, Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid substance contact. Avoid inhalation of dusts. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not empty into drains.

Cleanup methods

Take up dry.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact).

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
red
Colour Intensity
---
Form
solid
Odor
odourless
Odor Threshold
not applicable
Ph
ca. 9,2
Melting Point
295 - 296 °C
Boiling Point
not applicable
Flash Point
not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available.
Vapor Pressure
not applicable
Vapor Density
---
Relative Density
---
Bulk Density
ca.710 kg/m³
Density
---
Flammability
No information available.
Upper Explosive Limit
No information available.
Lower Explosive Limit
No information available.
Explosive Limits
---
Auto Ignition Temperature
No information available.
Decomposition Temperature
> 300 °C
Solubility
---
Partition Coefficient
log Pow: 4,80 (calculated) (Lit.) Potential bioaccumulation
Solubility In Water
300 g/l at 20 °C
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No information available.
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

hygroscopic

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

no information available

Avoid

Strong heating (decomposition).

Incompatible

no information available

Decomposition

in the event of fire: See section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®?

The signal word is warning.

What is the physical form of Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®?

Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain® is a solid with red color. It has odourless odor.

What is Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain® used for?

In vitro diagnostic reagent, Reagent for analysis

What are the hazard statements for Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of Eosin Y (yellowish) (C.I. 45380) for microscopy Certistain®?

The melting point is 295 - 296 °C and the boiling point is not applicable.