Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 1,2-Phenylenediamine GR for analysis
- Product Code
- 1.07243
- Chemical Name
- 1,2-Phenylenediamine
Regulatory Identifiers
- CAS Number
- 95-54-5 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Millipore
manufacturer
Merck Life Science BV/SRL
manufacturer
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| o-phenylenediamine EC: 202-430-6 | 95-54-5 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
Rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
Give water to drink (two glasses at most). Seek medical advice immediately. In exceptional cases only, if medical care is not available within one hour, induce vomiting (only in persons who are wide awake and fully conscious), administer activated charcoal (20 - 40 g in a 10% slurry) and consult a doctor as quickly as possible.
Immediate Medical Attention
Seek medical advice immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water Foam Carbon dioxide (CO2) Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up carefully. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Methenamine GR for analysis Reag. Ph Eur
---
Glyoxalbis(2-hydroxyanil) GR for analysis Reag. Ph Eur
CAS: 1149-16-2
N,N-Dimethyl-1,4-phenylenediamine Dihydrochloride [for Biochemical Research]
---
p-Phenylenediamine
CAS: 106-50-3
p-Phenylenediamine
CAS: 106-50-3
Resorcinol GR for analysis
CAS: 108-46-3
m-Phenylenediamine
CAS: 108-45-2
Ammonium monovanadate GR for analysis Reag. Ph Eur
CAS: 7803-55-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture.
Protected from light. Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons. Recommended storage temperature see product label.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A-(P3). The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: Strong oxidizing agents, Strong acids, Acid anhydrides, acid halides
Strong heating.
Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1673
- Shipping Name
- PHENYLENEDIAMINES
- Transport Class
- 6.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 1,2-Phenylenediamine GR for analysis?
The signal word is danger.
What is the physical form of 1,2-Phenylenediamine GR for analysis?
1,2-Phenylenediamine GR for analysis is a solid with light yellow color. It has no data available odor.
What is 1,2-Phenylenediamine GR for analysis used for?
Reagent for analysis
What are the hazard statements for 1,2-Phenylenediamine GR for analysis?
This substance has 7 hazard statements:
- H301: Toxic if swallowed.
- H312 + H332: Harmful in contact with skin or if inhaled.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H341: Suspected of causing genetic defects.
- H351: Suspected of causing cancer.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of 1,2-Phenylenediamine GR for analysis?
The melting point is 103 - 105 °C and the boiling point is 256 - 258 °C at 1.013 hPa.