NextSDS Logo
Safety Data Sheet EN

Spray Clean

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Spray Clean
Product Code
4002717 431020002 285002 285118

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Interior cleaner for professional use

Manufacturers & Suppliers

Greenspeed logo

Greenspeed

national supplier

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

+31703458737

http://www.greenspeed.eu/

Emergency Contacts

Emergency Contact

+32 70 245 245

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 8000

Emergency Contact

+ 33 (0)1 45 42 59 59

Emergency Contact

(+352) 8002-5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ethanol EC: 200-578-6 64-17-5 8% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of serious or continuous discomforts: remove to fresh air and seek medical attention.

Skin contact

Rinse with water.

Eye contact

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Redness

Ingestion

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Diarrhoea, headache, abdominal cramps, sleepiness, vomiting

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, foam, powder, sprayed water

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.

Environmental

Do not allow to flow into sewers or open water.

Cleanup methods

If possible, remove by using absorbent material.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle with care to avoid spillage.

Storage

Keep in a sealed container in a closed, frost-free, ventilated room.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Adequate ventilation should be provided so that exposure limits are not exceeded. For further information, check section 7.

Hands

Handling with nitril-gloves (EN 374). Breakthrough time: >480' Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.

Eyes

Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.

Respiratory

Respiratory protection is not required. Use ABEK type gas masks in case of irritating exposure. If necessary, use with sufficient exhaust ventilation.

Skin/Body

Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. For further information, check sections 6 and 13.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Not applicable
Melting Point
---
Kinematic Viscosity
1 mm²/s
Solubility In Water
Completely soluble
Decomposition Temperature
---
State Under Standard Conditions
---
Odor Threshold
---
Boiling Point
78 °C – 100 °C
Vapor Density
Not applicable
Solubility In Fat
---
Auto Ignition Temperature
370 °C
Freezing Point
---
Relative Evaporation Rate
---
Lower Explosive Limit
3.000 %
Form
---
Physical State
Liquid
Solubility
---
Cloud Point
---
Colour Intensity
---
Crystallisation Point
---
Evaporation Rate
2.000 (n-BuAc = 1)
Molecular Weight
---
Relative Density
0.9870 kg/l
Odor
characteristic
Flammability
Not applicable
Softening Point
---
Dynamic Viscosity
1 mPa.s
Flash Point
42 °C
Upper Explosive Limit
19.000 %
Vapor Pressure
5,850 Pa
Bulk Density
---
Appearance
---
Ph
6.3
Voc Content
7.50 %
Density
---
Metal Corrosion
---
Colour
colourless
Explosive Limits
---
Physical State Data
liquid
Properties Status
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Extremely high or low temperatures.

Reactivity

Stable under normal conditions.

Avoid

Protect from sunlight and do not expose to temperatures exceeding + 50°C.

Decomposition

Under recommended usage conditions, hazardous decomposition products are not expected.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Spray Clean?

The signal word is no signal word.

What is the physical form of Spray Clean?

Spray Clean is a liquid with colourless color. It has characteristic odor.

What is Spray Clean used for?

Interior cleaner for professional use