NextSDS Logo
Safety Data Sheet EN

TANEX POWER

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TANEX POWER

Regulatory Identifiers

CAS Number
N/A
UFI Code
5419-U0VU-800R-G9UA

Identified Uses

Cleaning agent

Manufacturers & Suppliers

T

Tana Chemie GmbH

manufacturer

Rheinallee 96, 55120 Mainz

+49613196403

Emergency Contacts

EU

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1-butoxypropan-2-ol EC: 225-878-4 5131-66-8 3 - 5% Yes
2,2'-methyliminodiethanol EC: 203-312-7 105-59-9 1 - 3% Yes
Decan-1-ol, ethoxylated EC: 500-046-6 26183-52-8 1 - 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion. If symptoms persist, call a physician.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water.

Eye contact

Protect unharmed eye. If easy to do, remove contact lens, if worn. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

For specialist advice physicians should contact the Poisons Information Service.

Medical Treatment

For specialist advice physicians should contact the Poisons Information Service.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Try to prevent the material from entering drains or water courses.

Cleanup methods

Neutralize with acid. Sweep up and shovel. Wipe up with absorbent material (e.g. cloth, fleece).

Materials: absorbent material (e.g. cloth, fleece)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special handling advice required.

Storage

Keep container tightly closed in a dry and well-ventilated place. Store at room temperature in the original container.

Hygiene

Wash hands before breaks and at the end of workday.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : For prolonged or repeated contact use protective gloves. It is suggested the usage of chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374. As alternative, a different type of gloves might be used if, accordingly to the recommendations of the producer, guarantee the same level of protection. Remarks : Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eyes

not required under normal use

Respiratory

not required under normal use

Skin/Body

not required under normal use

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
---
Properties Status
---
Solubility
---
Melting Point
---
Relative Density
---
Decomposition Temperature
---
Evaporation Rate
---
Vapor Pressure
---
Flash Point
does not flash
Vapor Density
---
Bulk Density
---
Odor
pleasant
Odor Threshold
---
Relative Evaporation Rate
---
Cloud Point
---
Freezing Point
---
Voc Content
---
Colour Intensity
---
Auto Ignition Temperature
---
Solubility In Fat
---
Physical State
liquid
Form
---
Appearance
---
State Under Standard Conditions
---
Crystallisation Point
---
Physical State Data
liquid
Solidification Point
---
Density
ca. 1,004 g/cm3 at 20 °C
Ph
ca. 11,0, 100 % at 20 °C
Lower Explosive Limit
---
Molecular Weight
---
Upper Explosive Limit
---
Metal Corrosion
---
Solubility In Water
completely miscible
Flammability
---
Partition Coefficient
---
Explosive Limits
---
Softening Point
---
Dynamic Viscosity
---
Colour
blue
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

No data available

Incompatible

No data available

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TANEX POWER?

The signal word is no signal word.

What is the physical form of TANEX POWER?

TANEX POWER is a liquid with blue color. It has pleasant odor.

What is TANEX POWER used for?

Cleaning agent