NextSDS Logo
Safety Data Sheet EN

Osmafin Aquablock Free

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Osmafin Aquablock Free
Product Form
Mixture
Product Code
621

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use; Hydrofobing agent / water repellent

Uses advised against

No additional information available

Manufacturers & Suppliers

Cole & Wilson, LLC logo

Cole & Wilson, LLC

manufacturer

100 Laurel Street Ste 120, USA– East Bridgewater, MA 02333, USA

+1 281 231 2805

http://www.coleandwilson.com

Christeyns UK Ltd. logo

Christeyns UK Ltd.

distributor

Rutland Street, GB– Bradford BD4 7EA, United Kingdom

+44 (0)1274 39 32 86

http://www.christeyns.com

Christeyns Food Hygiene Ltd. Ltd logo

Christeyns Food Hygiene Ltd. Ltd

distributor

2, Cameron Court, Winwick Quay, GB– WA2 8RE Warrington – Cheshire, United Kingdom

+44 (0)1925 23 46 96

http://www.christeyns.com

Casoria Company Ltd. Ltd logo

Casoria Company Ltd. Ltd

distributor

1 Farnham Street, IE– H12 A9K0 Cavan – Co. Cavan, Ireland

00353 49 4361869

http://www.casoria.ie

C

Christeyns Technologies Ltd.

distributor

Mazars, Block 3, Harcourt Centre, Harcourt Road, IE– 2 Dublin, Ireland

+353 1 8146022

Emergency Contacts

Chemtrec

1-800-424-9300

National Poisons Information Centre Beaumont Hospital

+353 1 809 2566

Healthcare professionals-24/7

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

public, 8am - 10pm, 7/7

National Poisons Information Service (Birmingham Centre) City Hospital

0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Functionalized polymer --- 3 - 5% Yes
Monopropyleneglycol; 1,2-propane glycol EC: 200-338-0 57-55-6 1 - 3% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take victim to fresh air, in a quiet place and if necessary take medical advice.

Symptoms: Presents no particular risk when handled in accordance with good occupational hygiene practice.

Skin contact

Take off immediately all contaminated clothing and wash it before reuse. In case of faintness or symptoms of skin irritation appear, take medical advice.

Symptoms: To our knowledge, this product does not present any particular risk, provided it is handled in accordance with good occupational hygiene and safety practice.

Eye contact

Wash with plenty of water (during 20 minutes minimum) with eyes wide open, keeping contact lenses and immediately take medical advice. If eye irritation persists, take medical advice.

Symptoms: To our knowledge, this product does not present any particular risk, provided it is handled in accordance with good occupational hygiene and safety practice.

Ingestion

Rinse mouth out with water. Do not induce vomiting. Get immediate medical advice/attention.

Symptoms: Presents no particular risk when handled in accordance with good occupational hygiene practice.

Immediate Medical Attention

Get immediate medical advice/attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing agents can be used.

Specific hazards

Explosion hazard : Not applicable.

Firefighter Protection

Use self-contained breathing apparatus and chemically protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Prevent entry to sewers and public waters. Avoid release to the environment.

Cleanup methods

Absorb spilled material with sand or earth. Shovel or sweep up and put in a closed container for disposal. Flush/dilute with water.

Materials: sand or earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure.

Storage

Keep only in original container. Keep out of frost.

Hygiene

Do not eat, drink or smoke when using this product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical resistant PVC gloves (to European standard EN 374 or equivalent)

Eyes

Safety glasses with side-shields (EN 166)

Respiratory

Ensure good ventilation

Skin/Body

No special required clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
White.
Colour Intensity
---
Form
Liquid.
Odor
slight.
Odor Threshold
Not available
Ph
3.9 ± 0,5
Melting Point
Not determined as it is not relevant for the characterization of the product
Boiling Point
≥ 100 °C
Flash Point
≥ 101 °C EN ISO 2719
Freezing Point
Not determined as it is not relevant for the characterization of the product
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not available
Vapor Density
---
Relative Density
1002 ± 25 kg/m3
Bulk Density
---
Density
---
Flammability
Not flammable
Upper Explosive Limit
Constituents do not contain chemical groups associated with explosivity
Lower Explosive Limit
Constituents do not contain chemical groups associated with explosivity
Explosive Limits
---
Auto Ignition Temperature
Determination of the auto-ignition temperature is only relevant for pyrophoric liquids, however the mixture is not a pyrophoric liquid so the test is not required.
Decomposition Temperature
Only applies to self-reactive substances and mixtures, organic peroxides, and other substances and mixtures that may decompose.
Solubility
Water: Miscible
Partition Coefficient
Does not apply to inorganic and ionic liquids and does not generally apply to mixtures.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
5 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored normally.

Reactivity

No additional information available

Hazardous reactions

No additional information available

Avoid

Temperatures below 0°C.

Incompatible

Never mix with other materials.

Decomposition

Hazardous decomposition products may be released during prolonged heating like smokes, carbon monoxide and dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

| Hazardous to the aquatic environment, short-term (acute) | : Not classified | | --- | --- | | Hazardous to the aquatic environment, long-term (chronic) | : Not classified | Monopropyleneglycol; 1,2-propane glycol (57-55-6)

The substance is not classified as hazardous to the aquatic environment, neither short-term (acute) nor long-term (chronic).

12.1. Toxicity

Monopropyleneglycol; 1,2-propane glycol (57-55-6) | LC50 - Fish [1] | 51400 mg/l | | --- | --- | | LC50 - Fish [2] | 51600 mg/l | | EC50 - Crustacea [1] | 34400 mg/l |

12.2. Persistence and degradability

The surfactant(s) contained in this preparation complies(comply) with the biodegradability criteria as laid down in Regulation (EC) No. 648/2004 on detergents. Data to support this assertion are held at the disposal of the competent authorities of the Member States and will be made available to them, at their direct request or at the request of a detergent manufacturer.

The surfactant(s) contained in this preparation complies(comply) with the biodegradability criteria as laid down in Regulation (EC) No. 648/2004 on detergents.

12.3. Bioaccumulative potential

Partition coefficient n-octanol/water (Log Kow) Does not apply to inorganic and ionic liquids and does not generally apply to mixtures. Monopropyleneglycol; 1,2-propane glycol (57-55-6)

Partition coefficient n-octanol/water (Log Kow) does not apply to inorganic and ionic liquids and does not generally apply to mixtures.

12.3. Bioaccumulative potential

| Monopropyleneglycol; 1,2-propane glycol (57-55-6) | | | Log Pow | -1.36 |

12.4. Mobility in soil

No additional information available

12.5. Results of PBT and vPvB assessment

No additional information available

12.6. Endocrine disrupting properties

No additional information available

12.7. Other adverse effects

No additional information available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Collect all waste in suitable and labelled containers and dispose according to local legislation.

Disposal

Collect all waste in suitable and labelled containers and dispose according to local legislation.

Waste Codes

07 06 01* aqueous washing liquids and mother liquors EWC
HP3 Flammable national code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No additional information available

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Osmafin Aquablock Free?

The signal word is no signal word.

What is the physical form of Osmafin Aquablock Free?

Osmafin Aquablock Free is a liquid with white. color. It has slight. odor.

What is the solubility of Osmafin Aquablock Free?

Water: Miscible

What is Osmafin Aquablock Free used for?

Professional use; Hydrofobing agent / water repellent

What is the melting point of Osmafin Aquablock Free?

The melting point is Not determined as it is not relevant for the characterization of the product and the boiling point is ≥ 100 °C.