Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RM 110 ASF Advance 1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Scale inhibitor
Manufacturers & Suppliers
Alfred Kärcher GmbH & Co. KG
manufacturer
Alfred-Kärcher-Str. 28-40, D - 71364 Winnenden, Postfach 160, D - 71349 Winnenden
+49-7195-14-0
http://www.karcher.com
Department PDE-D
manufacturer
+49-7195-14-2548
Emergency Contacts
Emergency Contact
+49-30-19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture consisting of the following components: dyes, dispersing agents, preservatives, water
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse with warm water.
Symptoms: Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water.
Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dilute with plenty of water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders).
Materials: sand, diatomite, acid binders, universal binders
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures required.
No special requirements.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Additional information about design of technical facilities: No further data; see item 7.
chemical resistant protective gloves (EN 374). Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: * butyl rubber 0,7 mm, 480 min. As protection from splashes gloves made of the following materials are suitable: * nitril rubber 0,4 mm, 30 min
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No dangerous reactions known
No decomposition if used according to specifications.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RM 110 ASF Advance 1?
The signal word is no signal word.
What is the physical form of RM 110 ASF Advance 1?
RM 110 ASF Advance 1 is a fluid with brown color. It has characteristic odor.
What is RM 110 ASF Advance 1 used for?
Scale inhibitor
What is the melting point of RM 110 ASF Advance 1?
The melting point is 0°C and the boiling point is 100°C.