01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RM 50036

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Process Oil

Manufacturers & Suppliers

C

Chevron Oronite S.A.S.

manufacturer

Le Corosa CS10022, 1, rue Eugène et Armand Peugeot, 92508 Rueil-Malmaison Cedex, France

+33 1 46 39 36 00

Emergency Contacts

Chevron Emergency Information Centre

+(1) 510-231-0623

Emergency Contact

1 800 009 010

Emergency Contact

(+86) 4001-204937

Emergency Contact

+(33)-975181407

Emergency Contact

+(1)-703-741-5970

CHEMTREC

(800) 424-9300

CHEMTREC

(703) 527-3887

Chevron Oronite Brasil Ltda

55 11 4478-1200

24 hours

NVIC

+31 (0)88 755 8000

Emergency Contact

(800) 231-0623

24 hours

Emergency Contact

(510) 231-0623

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Highly refined mineral oil (C15 - C50) --- 100% No

Notes

In accordance with the Regulation (EC) No 1272/2008, Nota L, reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation are not carcinogenic.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.

Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.

Skin contact

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, apply a waterless hand cleaner, mineral oil, or petroleum jelly. Then wash with soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

Symptoms: Contact with the skin is not expected to be harmful.

Eye contact

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.

Symptoms: Not expected to be harmful if swallowed.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Specific hazards

Combustion Products: Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Eliminate all sources of ignition in vicinity of spilled material. Refer to Sections 5 and 8 for more information.

Environmental

Stop the source of the release if you can do it without risk. | Contain release to prevent further contamination of soil, surface water or groundwater.

Cleanup methods

Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.

Storage

Not Applicable

Hygiene

Wash thoroughly after handling.

Fire prevention

Bonding and grounding may be necessary. Do not expose containers to heat, flame, sparks, static electricity, or other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Suggested materials for protective gloves include: Nitrile Rubber, Silver Shield, Viton.

Eyes

No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.

Respiratory

No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.

Skin/Body

No special protective clothing is normally required. Where splashing is possible, select protective clothing depending on operations conducted, physical requirements and other substances in the workplace.

Environmental

See relevant Community environmental protection legislation or the Annex, as applicable.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
No data available
Colour
No data available
Colour Intensity
---
Form
---
Odor
Petroleum odor
Odor Threshold
No data available
Ph
Not Applicable
Melting Point
---
Boiling Point
No data available
Flash Point
(Cleveland Open Cup) 200 °C (392 °F) (Minimum)
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
0.8790 @ 15°C (59°F)
Bulk Density
---
Density
No data available
Flammability
Not Applicable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Insoluble in water.
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
26.50 mm2/s @ 40°C (104°F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Do not heat above flash point.

Incompatible

Not applicable

Decomposition

None known (None expected)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.1 Toxicity

12.1 Toxicity

This material is not expected to be harmful to aquatic organisms. The product has not been tested. The statement has been derived from the properties of the individual components.

This material is not expected to be harmful to aquatic organisms. The product has not been tested.

12.2 Persistence and degradability

This material is not expected to be readily biodegradable. | The product has not been tested. The statement has been derived from the properties of the individual components.

The material is not expected to be readily biodegradable based on the properties of its individual components.

12.3 Bioaccumulative potential

Bioconcentration Factor: No Data Available Octanol/Water Partition Coefficient: No data available

12.4 Mobility in soil

No data available.

12.5 Results of PBT and vPvB assessment

This product is not, or does not contain, a substance that is a potential PBT or a vPvB.

The product is not, or does not contain, a substance that is a potential PBT or a vPvB.

12.6 Endocrine Disrupting Properties

This product is not, or does not contain, a substance that potentially has endocrine disrupting properties.

The product is not, or does not contain, a substance that potentially has endocrine disrupting properties.

12.7 Other adverse effects

No other adverse effects identified.

No other adverse effects identified.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible.

Disposal

This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.

Waste Codes

07 07 99 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No components of this material were found on the regulatory lists above (EU Directives 76/769/EEC, 90/394/EEC, 92/85/EEC, 96/82/EC, 98/24/EC, 2004/37/EC; EU Regulations EC No. 689/2008, 850/2004; EU REACH Annex XVII/XIV; Netherlands Cancer/Reprotoxic lists).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RM 50036?

The signal word is no signal word.

What is the physical form of RM 50036?

RM 50036 is a liquid appearing as no data available with no data available color. It has petroleum odor odor.

What is the solubility of RM 50036?

Insoluble in water.

What is RM 50036 used for?

Process Oil