Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CHEMAL CORREX 36
- Product Code
- 2507001
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Metal surface treatment
Manufacturers & Suppliers
CHEMAL Katschmareck GmbH & Co. KG
manufacturer
Heinrich-Welken-Str. 8, D-59069 Hamm, Germany
+49.(0)2385.91010-0
Emergency Contacts
Information center for toxication
0228/19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated light EC: 265-149-8 | 64742-47-8 | 10 - 25% | Yes |
| 2-butoxyethanol EC: 203-905-0 | 111-76-2 | 2.5 - 10% | Yes |
| 2-(2-heptadec-8-enyl-2-imidazolin-1-yl)ethanol EC: 204-414-9 | 95-38-5 | 2.5 - 10% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 2.5 - 10% | Yes |
| Orangenöl | 8028-48-6 | 2.5% | Yes |
For the wording of the listed risk phrases refer to section 16.
Notes
Dangerous components:
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
In case of fire, the following can be released: carbon oxides, vapours harmful to health
Firefighter Protection
Wear self-contained respiratory protective device. Do not inhale explosion gases or combustion gases.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep away from ignition sources. Ensure adequate ventilation. Avoid eye- and skincontact as soon as inhalaton.
Prevent from spreading (e.g. by damming-in or oil barriers).
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well ventilated areas. Open fire ignition to be avoided. Take measures against electrostatical charging.
No storage of product in passages and on staircases. Product has to be stores in original packaging and closed. Please adhere to be special specifications for aerosols. To protect against solar radiation and temperatures over 50°C. To keep aired place.
Open fire ignition to be avoided. Take measures against electrostatical charging.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
After each cleaning use treatment creams, for very dry skin greasy ointments. Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR, Fluorocarbon rubber (Viton). The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Goggles recommended during refilling.
Going beyond the MAK-Value. Gas mask and breathing equipment A (EN 141)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No decomposition if used according to specifications.
Heating, open fire, ignition sources. An increase of pressure leads to bursting risk
Avoid contact with oxidic materials. Avoid contac with other chemicals
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Transport Class
- 2.1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CHEMAL CORREX 36?
The signal word is na: r-phrases.
What is the physical form of CHEMAL CORREX 36?
CHEMAL CORREX 36 is a fluid with yellow color. It has characteristic odor.
What is CHEMAL CORREX 36 used for?
Metal surface treatment
What is the melting point of CHEMAL CORREX 36?
The melting point is -50°C and the boiling point is 175°C.