Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- deconex 12 PA-x
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- EHG6-20R5-700R-CVAV
Identified Uses
Cleaning material/ Detergent
Manufacturers & Suppliers
Borer Chemie AG
manufacturer
Gewerbestr. 13, CH-4528 Zuchwil, Schweiz
+41 32 686 56 00
Borer Chemie Deutschland GmbH
distributor
Lützeltaler Str. 3, 63868 Grosswallstadt, Germany
+49 6022 26557-0
Carl Roth GmbH + Co KG
distributor
Schoemperlenstr. 3-5, 76185 Karlsruhe, Germany
+49 721 5606 0
Emergency Contacts
Giftnotruf der Charité, Berlin
030/19240
Giftinformationszentrum-Nord der Länder Bremen, Hamburg, Niedersachsen und Schleswig-Holstein (GIZ-Nord)
0551/19 240
Informationszentrale gegen Vergiftungen Zentrum für Kinderheilkunde Universitätsklinikum Bonn
0228/19240
Giftnotruf Erfurt Gemeinsames Giftinformationszentrum der Länder Mecklenburg-Vorpommern, Sachsen, Sachsen-Anhalt und Thüringen
0361/730 730
Informations- und Beratungszentrum für Vergiftungsfälle Klinik für Kinder- und Jugendmedizin Universitätsklinikum des Saarlandes
06841/19240
Giftinformationszentrum der Länder Rheinland-Pfalz und Hessen - Klinische Toxikologie - Universitätsmedizin der Johannes Gutenberg-Universität Mainz
06131/19240
Vergiftungs-Informations-Zentrale Zentrum für Kinder- und Jugendmedizin Universitätsklinikum
0761/19240
Giftnotruf München Toxikologische Abteilung der II. Med. Klinik und Poliklinik
089/19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| tripotassium phosphate EC: 231-907-1 | 7778-53-2 | 15 - 30% | Yes |
| potassium hydroxide EC: 215-181-3 | 1310-58-3 | 1% | Yes |
| fatty alcohol alkoxylate | 69013-18-9 | 1% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness place patient stably in side position for transportation. Supply fresh air.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Then consult a doctor.
If symptoms persist consult doctor.
Immediate Medical Attention
Consult a doctor after eye contact or if symptoms persist after swallowing.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions. Water spray, Foam, Fire-extinguishing powder.
Full water jet
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material, Use neutralising agent
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Optimum storage temperature 20°C. For details, see the product label.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Control potential exposure through measures such as encapsulated or self-contained systems, properly designed and maintained installations and sufficient ventilation standards. Shut down systems and empty pipelines before opening the plant. Wherever possible, shut down and flush the plant before maintenance work.
The protective gloves to be used must satisfy the specification of EC Directive 89/686/EEC and the resulting EN374 standard. Protective gloves. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.7 mm. Penetration time of glove material Penetration time: > 480 min.
Tightly sealed goggles
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
In agreement with legal requirements, absorb any spills and dispose of waste.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
Exothermic reaction with: Acids
Thermal decomposition above 230 °C.
Do not store together with acids.
Thermal decomposition can cause the release of irritant gases and vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3266
- Shipping Name
- CORROSIVE LIQUID, BASIC, INORGANIC, N.O.S. (tripotassium phosphate)
- Transport Class
- 8
- Packing Group
- III
Warning: Corrosive substances.
Warning: Corrosive substances. Stowage Category A, SW2 Clear of living quarters. Segregation groups (SGG18) Alkalis, SG35 Stow 'separated from' SGG1-acids
Warning: Corrosive substances.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for deconex 12 PA-x?
The signal word is danger.
What is the physical form of deconex 12 PA-x?
deconex 12 PA-x is a fluid with colourless to yellow color. It has characteristic odor.
What is deconex 12 PA-x used for?
Cleaning material/ Detergent
What are the hazard statements for deconex 12 PA-x?
This substance has 5 hazard statements:
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of deconex 12 PA-x?
The melting point is Not relevant and the boiling point is 100 °C.