NextSDS Logo
Safety Data Sheet EN

Alpacon multi CIP II

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Alpacon multi CIP II

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaning material/ Detergent

Manufacturers & Suppliers

Alfa Laval Tumba AB logo

Alfa Laval Tumba AB

manufacturer

Hans Stahles väg 7, S-147 80 Tumba, Sweden

+46 8 530 650 00

http://www.alfalaval.com

Emergency Contacts

Emergency Contact

911

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H315 Causes skin irritation.
H318 Causes serious eye damage.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P302 + P352 If on skin: Wash with plenty of water.
P305 + P351 + P338 If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P309 + P311 IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Ethoxylated alcohol C 9/11 68439-46-3 10 - 25% Yes
Quaternary coco alkyl methyl amine ethoxylate methyl chloride 863679-20-3 10 - 15% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Symptoms: Corrosive effects. Allergic reactions

Eye contact

Rinse opened eye for several minutes under running water and consult a doctor. Rinse cautiously with water for 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Symptoms: Can cause permanent eye damage.

Ingestion

Wash the mouth with water. Immediately call a doctor. If swallowed, do not induce vomiting: seek medical advice immediately and show this container or label.

Immediate Medical Attention

Immediately call a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product is not flammable. Use fire fighting measures that suit the environment.

Unsuitable media

Not applicable.

Specific hazards

No further relevant information available.

Firefighter Protection

Protective equipment: No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapour.

Small spill

Small spillages (<20L) can be washed out with water into drain. (10:1) Dilute with plenty water.

Environmental

Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system. Dilute with plenty of water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

When using do not eat or drink. When using do not eat, drink or smoke. See Section 8 for information on personal protection equipment.

Storage

Store in a dry place. Keep container tightly closed.

Hygiene

When using do not eat or drink. When using do not eat, drink or smoke.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only in well-ventilated areas.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: PVC gloves, Nitrile rubber, NBR, Chloroprene rubber, CR, Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.

Skin/Body

Working clothes

Environmental

Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system. Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water. Send for recovery or disposal in suitable receptacles.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Form: Liquid Color: Brown
Colour
Brown
Colour Intensity
---
Form
Liquid
Odor
Nearly odorless
Odor Threshold
Not determined.
Ph
9,5
Melting Point
0 °C (32 °F)
Boiling Point
100 °C (212 °F)
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
1,0 g/cm³ (8.345 lbs/gal)
Bulk Density
---
Density
1 g/cm³ (8.345 lbs/gal)
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
0,00 %
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Alpacon multi CIP II?

The signal word is danger.

What is the physical form of Alpacon multi CIP II?

Alpacon multi CIP II is a liquid appearing as form: liquid color: brown with brown color. It has nearly odorless odor.

What is Alpacon multi CIP II used for?

Cleaning material/ Detergent

What are the hazard statements for Alpacon multi CIP II?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.

What is the melting point of Alpacon multi CIP II?

The melting point is 0 °C (32 °F) and the boiling point is 100 °C (212 °F).