NextSDS Logo
Safety Data Sheet EN

3M™ Cavilon™ No Sting Barrier Film Spray (IO)

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
3M™ Cavilon™ No Sting Barrier Film Spray (IO)
Product Code
3346, 3346E, 3346P

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Skin protectant barrier film.

Manufacturers & Suppliers

3

3M

manufacturer

3M Center, St. Paul, MN 55144-1000, USA

1-888-3M HELPS (1-888-364-3577)

Emergency Contacts

Emergency Contact

1-800-364-3577

24 hours

Emergency Contact

(651) 737-6501

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2
Asp. Tox. Cat. 1

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor.
H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P233 Keep container tightly closed.
P240 Ground/bond container and receiving equipment.
P241 Use explosion-proof electrical/ventilating/lighting equipment.
P242 Use only non-sparking tools.
P243 Take precautionary measures against static discharge.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P331 Do NOT induce vomiting.
P370 + P378 In case of fire: Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up.
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Isooctane 540-84-1 5 - 15% No
Acrylate Terpolymer --- 3 - 10% No
Polyphenylmethylsiloxane Copolymer 70131-69-0 0.1 - 5% No
Hexamethyldisiloxane 107-46-0 70 - 90% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air. If you feel unwell, get medical attention.

Skin contact

No need for first aid is anticipated.

Eye contact

No need for first aid is anticipated.

Ingestion

Do not induce vomiting. Get immediate medical attention.

Immediate Medical Attention

Get immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.

Unsuitable media

Water may not effectively extinguish fire

Specific hazards

Closed containers exposed to heat from fire may build pressure and explode.

Instructions

Water should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.

Firefighter Protection

Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate area. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.

Large spill

For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.

Environmental

Avoid release to the environment.

Cleanup methods

Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Seal the container.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep out of reach of children. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) Wear low static or properly grounded shoes. To minimize the risk of ignition, determine applicable electrical classifications for the process using this product and select specific local exhaust ventilation equipment to avoid flammable vapor accumulation. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.

Storage

Store in a well-ventilated place. Keep cool. Keep container tightly closed. Store away from heat.

Hygiene

Do not eat, drink or smoke when using this product. Wash thoroughly after handling.

Fire prevention

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. Use explosion-proof ventilation equipment.

Hands

No protective gloves required.

Eyes

Eye protection not required.

Respiratory

An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates For questions about suitability for a specific application, consult with your respirator manufacturer.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Solidification Point
---
Vapor Density
Not Applicable
State Under Standard Conditions
---
Metal Corrosion
---
Partition Coefficient
Not Applicable
Odor Threshold
No Data Available
Flash Point
14 °F [Test Method: Closed Cup]
Molecular Weight
---
Odor
Slight Odor, Odorless
Colour Intensity
---
Crystallisation Point
---
Solubility In Water
<=.1 % [Test Method: Tested per ASTM protocol]
Melting Point
Not Applicable
Physical State
Liquid
Explosive Limits
---
Voc Content
720 g/l
Appearance
---
Density
0.78 g/ml
Vapor Pressure
< 27 psia [@ 131 °F]
Softening Point
---
Properties Status
---
Freezing Point
---
Relative Density
0.78 [Test Method: Tested per ASTM protocol] [Ref Std: WATER=1]
Upper Explosive Limit
18.3 %
Boiling Point
212 °F [Test Method: Tested per ASTM protocol]
Decomposition Temperature
No Data Available
Bulk Density
---
Flammability
Not Applicable
Cloud Point
---
Physical State Data
liquid
Ph
Not Applicable
Form
---
Solubility In Fat
---
Auto Ignition Temperature
665 °F
Colour
Colorless
Dynamic Viscosity
5 centipoise [Test Method: Tested per ASTM protocol]
Lower Explosive Limit
0.7 %
Solubility
---
Evaporation Rate
<=1 [Test Method: Tested per ASTM protocol] [Ref Std: ETHER=1]
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Heat, Sparks and/or flames

Incompatible

Strong oxidizing agents

Decomposition

None known. Refer to section 5.2 for hazardous decomposition products during combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?

The signal word is danger.

What is the physical form of 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?

3M™ Cavilon™ No Sting Barrier Film Spray (IO) is a liquid with colorless color. It has slight odor, odorless odor.

What is 3M™ Cavilon™ No Sting Barrier Film Spray (IO) used for?

Skin protectant barrier film.

What are the hazard statements for 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?

This substance has 2 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H304: May be fatal if swallowed and enters airways.

What is the melting point of 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?

The melting point is Not Applicable and the boiling point is 212 °F [Test Method: Tested per ASTM protocol].