Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 3M™ Cavilon™ No Sting Barrier Film Spray (IO)
- Product Code
- 3346, 3346E, 3346P
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Skin protectant barrier film.
Manufacturers & Suppliers
3M
manufacturer
3M Center, St. Paul, MN 55144-1000, USA
1-888-3M HELPS (1-888-364-3577)
Emergency Contacts
Emergency Contact
1-800-364-3577
24 hours
Emergency Contact
(651) 737-6501
24 hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isooctane | 540-84-1 | 5 - 15% | No |
| Acrylate Terpolymer | --- | 3 - 10% | No |
| Polyphenylmethylsiloxane Copolymer | 70131-69-0 | 0.1 - 5% | No |
| Hexamethyldisiloxane | 107-46-0 | 70 - 90% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air. If you feel unwell, get medical attention.
No need for first aid is anticipated.
No need for first aid is anticipated.
Do not induce vomiting. Get immediate medical attention.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
Water may not effectively extinguish fire
Closed containers exposed to heat from fire may build pressure and explode.
Water should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.
Firefighter Protection
Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.
For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.
Avoid release to the environment.
Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Seal the container.
Related Products
Similar products with comparable safety profiles
3M™ Cavilon™ No Sting Barrier Film with Foam Applicator (IO) 3343, 3344, 3345, 3343E, 3344E, 3345E, 3343P, 3345P, 3343K, 3344ENS
---
3M(TM) Cavilon(TM) No Sting Barrier Film with Foam Applicator (IO) 3343, 3344, 3345, 3343E, 3344E, 3345E, 3343P, and 3345P
---
3M™ Cavilon™ Advanced Skin Protectant
---
3M™ Ioban™ 2 Antimicrobial Incise Drapes 6035, 6040, 6048, 6050, 6051, 6635, 6640, 6648, 6650 and 6651
---
3M Spray 74 Foam Adhesive
---
OPSITE® Spray
---
Opsite Spray Dressing
---
Cederroth Eye&Wound Cleansing Spray
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep out of reach of children. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) Wear low static or properly grounded shoes. To minimize the risk of ignition, determine applicable electrical classifications for the process using this product and select specific local exhaust ventilation equipment to avoid flammable vapor accumulation. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.
Store in a well-ventilated place. Keep cool. Keep container tightly closed. Store away from heat.
Do not eat, drink or smoke when using this product. Wash thoroughly after handling.
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. Use explosion-proof ventilation equipment.
No protective gloves required.
Eye protection not required.
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates For questions about suitability for a specific application, consult with your respirator manufacturer.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.
Hazardous polymerization will not occur.
Heat, Sparks and/or flames
Strong oxidizing agents
None known. Refer to section 5.2 for hazardous decomposition products during combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?
The signal word is danger.
What is the physical form of 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?
3M™ Cavilon™ No Sting Barrier Film Spray (IO) is a liquid with colorless color. It has slight odor, odorless odor.
What is 3M™ Cavilon™ No Sting Barrier Film Spray (IO) used for?
Skin protectant barrier film.
What are the hazard statements for 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
What is the melting point of 3M™ Cavilon™ No Sting Barrier Film Spray (IO)?
The melting point is Not Applicable and the boiling point is 212 °F [Test Method: Tested per ASTM protocol].