NextSDS Logo
Safety Data Sheet EN

Iodide/iodate solution N/64

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Iodide/iodate solution N/64
Product Code
921

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

Laboratoires Dujardin-Salleron logo

Laboratoires Dujardin-Salleron

manufacturer

37210 Noizay France

+33 (0)2 47 25 58 25

www.dujardin-salleron.com

Emergency Contacts

INRS

+33 (0)1 45 42 59 59

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Potassium iodide EC: 231-659-4 7681-11-0 1.7% Yes
Potassium iodate EC: 231-831-9 --- 0.06% Yes
Potassium hydroxide EC: 215-181-3 1310-58-3 0.02% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Symptoms: Cough, Shortness of breath.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water. Call in ophthalmologist.

Ingestion

immediately make victim drink water (two glasses at most). Consult a physician.

Immediate Medical Attention

Call in ophthalmologist. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, carbon dioxide (CO₂), foam, dry powder.

Unsuitable media

For this mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapors (development of hydriodic acid).

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid substance contact. Do not breathe vapors, aerosols. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not empty into drains.

Cleanup methods

Take up with liquid-absorbent and neutralizing material, e.g. Trivorex ® (PREVOR). Clean up affected area.

Materials: liquid-absorbent and neutralizing material, e.g. Trivorex ® (PREVOR)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Protected from light. Store at +15°C to +25°C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

Wear exclusively gloves special chemistry provided with a CE marking. If gloves must be reused, clean them before removing them and keeping them in a well ventilated place. full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min Splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374.

Eyes

Safety glasses

Respiratory

Required when vapors/aerosols are generated. Recommended filter type: P 2. The company has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Carry protective clothing for chemicals appropriate, provided with a CE marking.

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Solubility In Water
soluble at 20°C.
Explosive Limits
---
Upper Explosive Limit
No information available.
Colour Intensity
---
Ph
No information available.
Lower Explosive Limit
No information available.
Properties Status
---
Flammability
not applicable
Dynamic Viscosity
No information available.
Relative Density
ca.1.07 g/cm³ at 20°C.
Auto Ignition Temperature
No information available.
State Under Standard Conditions
---
Boiling Point
No information available.
Solubility In Fat
---
Molecular Weight
---
Metal Corrosion
---
Odor
odorless.
Decomposition Temperature
No information available.
Appearance
---
Bulk Density
---
Physical State Data
liquid
Vapor Density
---
Crystallisation Point
---
Colour
colorless.
Evaporation Rate
No information available.
Voc Content
---
Solubility
---
Softening Point
---
Solidification Point
---
Density
---
Freezing Point
---
Flash Point
No information available.
Vapor Pressure
No information available.
Cloud Point
---
Melting Point
No information available.
Form
liquid.
Physical State
liquid
Odor Threshold
No information available.
Partition Coefficient
No information available.
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable during 6 months under standard ambient conditions (room temperature).

Reactivity

See below

Hazardous reactions

No information available.

Avoid

No information available

Incompatible

No information available

Decomposition

In the event of fire: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Iodide/iodate solution N/64?

The signal word is no signal word.

What is the physical form of Iodide/iodate solution N/64?

Iodide/iodate solution N/64 is a liquid with colorless. color. It has odorless. odor.

What is Iodide/iodate solution N/64 used for?

Reagent for analysis

What is the melting point of Iodide/iodate solution N/64?

The melting point is No information available. and the boiling point is No information available..