Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Iodide/iodate solution N/64
- Product Code
- 921
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Laboratoires Dujardin-Salleron
manufacturer
37210 Noizay France
+33 (0)2 47 25 58 25
www.dujardin-salleron.com
Emergency Contacts
INRS
+33 (0)1 45 42 59 59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Symptoms: Cough, Shortness of breath.
wash off with plenty of water. Remove contaminated clothing.
rinse out with plenty of water. Call in ophthalmologist.
immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Call in ophthalmologist. Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, carbon dioxide (CO₂), foam, dry powder.
For this mixture no limitations of extinguishing agents are given.
Not combustible. Ambient fire may liberate hazardous vapors (development of hydriodic acid).
Suppress (knock down) gases/vapors/mists with a water spray jet.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid substance contact. Do not breathe vapors, aerosols. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not empty into drains.
Take up with liquid-absorbent and neutralizing material, e.g. Trivorex ® (PREVOR). Clean up affected area.
Materials: liquid-absorbent and neutralizing material, e.g. Trivorex ® (PREVOR)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Tightly closed. Protected from light. Store at +15°C to +25°C.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
Wear exclusively gloves special chemistry provided with a CE marking. If gloves must be reused, clean them before removing them and keeping them in a well ventilated place. full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min Splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374.
Safety glasses
Required when vapors/aerosols are generated. Recommended filter type: P 2. The company has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Carry protective clothing for chemicals appropriate, provided with a CE marking.
Do not empty into drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable during 6 months under standard ambient conditions (room temperature).
See below
No information available.
No information available
No information available
In the event of fire: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Iodide/iodate solution N/64?
The signal word is no signal word.
What is the physical form of Iodide/iodate solution N/64?
Iodide/iodate solution N/64 is a liquid with colorless. color. It has odorless. odor.
What is Iodide/iodate solution N/64 used for?
Reagent for analysis
What is the melting point of Iodide/iodate solution N/64?
The melting point is No information available. and the boiling point is No information available..