NextSDS Logo
Safety Data Sheet EN

Iodine solution according WIJS 0.1 mol/l

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Iodine solution according WIJS 0.1 mol/l
Product Code
CL05.1004

Regulatory Identifiers

CAS Number
N/A
REACH No.
is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

C

CHEM-LAB NV

manufacturer

Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM

+32 50 28 83 20

Emergency Contacts

Emergency Contact

00 (32) 50.28.83.20

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Met. Corr. Cat. 1 H290
Skin Corr. H314

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

Hazard Statements

H226 Flammable liquid and vapour.
H290 May be corrosive to metals.
H314 Causes severe skin burns and eye damage.

Precautionary Statements

P210 Keep away from heat, sparks, open flames, hot surfaces. No smoking.
P280 Wear protective gloves, protective clothing, eye protection, face protection.
P301 + P330 + P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P309 + P311 IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Iodine, pellets v.p. 7553-56-2 0.5% Yes
Acetic acid 99-100% v.p. 64-19-7 90% Yes

For the full text of H-Phrases mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air, seek medical advice.

Skin contact

Wash off with plenty of water. Dab with polyethylene glycol 400. Remove contaminated clothing. Immediately call in physician.

Eye contact

Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. lmmediately call an ophtalmologist.

Ingestion

Never give anything by mouth to an unconscious person. Make victim drink water (two glasses at most), avoid vomiting (risk of perforation!). lmmediately call in physician. Do not attempt to neutralize.

Immediate Medical Attention

No data available

Medical Treatment

No data available

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

Hands

Required.

Eyes

Required.

Respiratory

Required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Required.

Environmental

Do not allow to enter sewerage system; risk of explosion!

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Density
1,06 g/ml
Colour
Brown
Ph
---
Solidification Point
---
Vapor Density
---
Melting Point
---
Evaporation Rate
---
Cloud Point
---
Decomposition Temperature
---
Molecular Weight
---
Relative Density
---
Metal Corrosion
---
Vapor Pressure
---
Lower Explosive Limit
---
Odor
specific
Explosive Limits
---
Boiling Point
---
Physical State
Liquid
Form
Liquid
Appearance
---
Kinematic Viscosity
---
Properties Status
---
Physical State Data
liquid
Upper Explosive Limit
---
Softening Point
---
Crystallisation Point
---
Flammability
---
Dynamic Viscosity
---
Solubility In Fat
---
Solubility In Water
insoluble
Solubility
---
Partition Coefficient
---
Relative Evaporation Rate
---
Odor Threshold
---
Colour Intensity
---
Auto Ignition Temperature
---
Freezing Point
---
Flash Point
40C
Bulk Density
---
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN 2789
Shipping Name
Acetic acid, glacial
Transport Class
8 (3)
Packing Group
II
ADR

no

IMDG

no

IATA

no

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Iodine solution according WIJS 0.1 mol/l?

The signal word is danger.

What is the physical form of Iodine solution according WIJS 0.1 mol/l?

Iodine solution according WIJS 0.1 mol/l is a liquid with brown color. It has specific odor.

What is Iodine solution according WIJS 0.1 mol/l used for?

Reagent for analysis

What are the hazard statements for Iodine solution according WIJS 0.1 mol/l?

This substance has 3 hazard statements:

  • H226: Flammable liquid and vapour.
  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.