NextSDS Logo
Io

Iodine solution according WIJS 0.1 mol/l

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Iodine solution according WIJS 0.1 mol/l
Product Code
CL05.1004

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis

Overview

Iodine solution according WIJS 0.1 mol/l commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger :)

Hazard Classifications

Flam. Liq. Category 3 H226
Met. Corr. Category 1 H290
Skin Corr. H314

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.
  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.

Precautionary Statements

  • P210: Keep away from heat, sparks, open flames, hot surfaces. No smoking.
  • P280: Wear protective gloves, protective clothing, eye protection, face protection.
  • P301 + P330 + P331: IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P309 + P311: IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CHEM-LAB NV

manufacturer

๐Ÿ“

Industriezone De Arend 2 B-8210 ZEDELGEM - BELGIUM

๐ŸŒ

BE

๐Ÿ“ž

+32 50 28 83 20

๐Ÿ“ 

+32 50 78 26 54

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

00 (32) 50.28.83.20

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Iodine, pellets v.p. 7553-56-2 0.5% โš ๏ธ Hazardous
Acetic acid 99-100% v.p. 64-19-7 90% โš ๏ธ Hazardous

Additional Information

For the full text of H-Phrases mentioned in this Section, see Section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air, seek medical advice.

๐Ÿ–๏ธ Skin Contact

Wash off with plenty of water. Dab with polyethylene glycol 400. Remove contaminated clothing. Immediately call in physician.

๐Ÿ‘๏ธ Eye Contact

Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. lmmediately call an ophtalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Make victim drink water (two glasses at most), avoid vomiting (risk of perforation!). lmmediately call in physician. Do not attempt to neutralize.

๐Ÿšจ Immediate Medical Attention Required

No data available

Medical Treatment

No data available

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
specific
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
40C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,06 g/ml
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

๐Ÿงค Hand Protection

Required.

๐Ÿ‘๏ธ Eye Protection

Required.

๐Ÿ˜ท Respiratory Protection

Required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

Required.

๐ŸŒ Environmental Exposure Controls

Do not allow to enter sewerage system; risk of explosion!

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 2789

๐Ÿ“ฆ Proper Shipping Name

Acetic acid, glacial

โš ๏ธ Transport Hazard Class

8 (3)

๐Ÿ“‹ Packing Group

II

๐Ÿš› ADR Transport Precautions

no

๐Ÿšข IMDG Maritime Transport Precautions

no

โœˆ๏ธ IATA Air Transport Precautions

no

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Iodine solution according WIJS 0.1 mol/l?

The signal word for this substance is "danger".

What is the physical form of Iodine solution according WIJS 0.1 mol/l?

Iodine solution according WIJS 0.1 mol/l is a liquid with brown color. It has specific odor.

What is Iodine solution according WIJS 0.1 mol/l used for?

Reagent for analysis

What are the hazard statements for Iodine solution according WIJS 0.1 mol/l?

This substance has 3 hazard statements: H226: Flammable liquid and vapour. H290: May be corrosive to metals. H314: Causes severe skin burns and eye damage.