Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Brake Parts Cleaner 2
- Product Code
- 86920
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaner solvent
Manufacturers & Suppliers
KENT (United Kingdom) Ltd
manufacturer
Forsyth House, Pitreavie Drive, Pitreavie Business Park, Dunfermline, Fife, KY11 8US
+44 01383 723344 / 0800 136925
Emergency Contacts
Emergency Contact
+44 01383 723344
Monday - Thursday 8.30am - 5.30pm, Friday 9.00am - 3.00pm
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane EC: 921-024-6 | --- | 50 - 75% | Yes |
| xylene EC: 215-535-7 | 1330-20-7 | 10 - 25% | Yes |
| Acetone EC: 200-662-2 | 67-64-1 | 5 - 10% | Yes |
| Carbon dioxide EC: 204-696-9 | 124-38-9 | 5% | No |
| Ethylbenzene EC: 202-849-4 | 100-41-4 | 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness bring patient into stable side position for transport.
If skin irritation continues, consult a doctor.
Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.
In case of persistent symptoms consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment.
Formation of toxic gases is possible during heating or in case of fire. Formation of poisonous gases during heating or in fires.
Firefighter Protection
Wear self-contained breathing apparatus. Do not inhale explosion gases or combustion gases. Put on breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter drainage system, surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Ensure good ventilation/exhaustion at the workplace. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use. Do not spray on flames or red-hot objects. Keep ignition sources away - Do not smoke. Keep breathing equipment ready.
Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep away from heat and direct sunlight. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known
No decomposition if used according to specifications.
Oxidizing agents
Formation of toxic gases is possible during heating or in case of fire. Carbon monoxide and carbon dioxide. Aldehydes
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow "separated from" class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Brake Parts Cleaner 2?
The signal word is danger.
What is the physical form of Brake Parts Cleaner 2?
Brake Parts Cleaner 2 is a aerosol with clear color. It has characteristic odor.
What is Brake Parts Cleaner 2 used for?
Cleaner solvent
What are the hazard statements for Brake Parts Cleaner 2?
This substance has 8 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H373: May cause damage to organs through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Brake Parts Cleaner 2?
The melting point is Not determined and the boiling point is Not applicable, as aerosol.