Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LEYBOLD - LEYBONOL LVO 120
- Product Code
- 300332691
- Synonyms
- L12000; L12001; L12002; L12005; L12020
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Compressor oil
Uses advised against
No specific uses advised against are identified.
Manufacturers & Suppliers
Leybold GmbH
manufacturer
Bonner Str. 498 Cologne D-50968 Germany
+49 221 3470
https://www.leybold.com
Emergency Contacts
CHEMWATCH EMERGENCY RESPONSE (24/7)
+49 32 211121704 (ID#: 5311-10)
24/7
CHEMWATCH EMERGENCY RESPONSE (24/7)
+61 3 9573 3188
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
See 'Composition on ingredients' in Section 3.2
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| mineral oil (highly refined) | --- | --- | No |
| (DMSO <3% w/w - IP346) | --- | --- | No |
Notes
Legend:1. Classified by Chemwatch; 2. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI; 3. Classification drawn from C&L; * EU IOELVs available; [e] Substance identified as having endocrine disrupting properties
First Aid Measures
Emergency procedures for chemical exposure incidents
If fumes or combustion products are inhaled remove from contaminated area. Lay patient down. Keep warm and rested. Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures. Apply artificial respiration if not breathing, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained. Perform CPR if necessary. Transport to hospital, or doctor.
Immediately remove all contaminated clothing, including footwear. Flush skin and hair with running water (and soap if available). Seek medical attention in event of irritation.
Wash out immediately with fresh running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Seek medical attention without delay; if pain persists or recurs seek medical attention. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
If swallowed do NOT induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open airway and prevent aspiration. Observe the patient carefully. Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming unconscious. Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink. Seek medical advice.
Medical Treatment
Treat symptomatically. High pressure accidental injection through the skin should be assessed for possible incision, irrigation and/or debridement.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Dry chemical powder, Carbon dioxide, Water spray or fog - Large fires only.
Do not use water jets.
Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result
Alert Fire Brigade and tell them location and nature of hazard. Use water delivered as a fine spray to control fire and cool adjacent area. Do not approach containers suspected to be hot. Cool fire exposed containers with water spray from a protected location. If safe to do so, remove containers from path of fire.
Firefighter Protection
Wear breathing apparatus plus protective gloves.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
See section 8
Slippery when spilt. • Remove all ignition sources. • Clean up all spills immediately. • Avoid breathing vapours and contact with skin and eyes. • Control personal contact with the substance, by using protective equipment. • Contain and absorb spill with sand, earth, inert material or vermiculite. • Wipe up. • Place in a suitable, labelled container for waste disposal.
Slippery when spilt. Moderate hazard. • Clear area of personnel and move upwind. • Alert Fire Brigade and tell them location and nature of hazard. • Wear breathing apparatus plus protective gloves. • Prevent, by any means available, spillage from entering drains or water course. • No smoking, naked lights or ignition sources. • Increase ventilation. • Stop leak if safe to do so. • Contain spill with sand, earth or vermiculite. • Collect recoverable product into labelled containers for recycling. • Absorb remaining product with sand, earth or vermiculite. • Collect solid residues and seal in labelled drums for disposal. • Wash area and prevent runoff into drains. • If contamination of drains or waterways occurs, advise emergency services.
See section 12
Wipe up. Collect recoverable product into labelled containers for recycling. Absorb remaining product with sand, earth or vermiculite. Collect solid residues and seal in labelled drums for disposal. Wash area and prevent runoff into drains.
Materials: sand, earth, inert material or vermiculite
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid skin contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Prevent concentration in hollows and sumps. DO NOT enter confined spaces until atmosphere has been checked. DO NOT allow material to come in direct contact with human skin or eyes. DO NOT allow material to come in contact with exposed food or food contact surfaces. Suitable PPE must be worn at all times. Avoid contact with incompatible materials. When handling, DO NOT eat, drink or smoke. Keep containers securely sealed when not in use. Avoid physical damage to containers. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Launder contaminated clothing before re-use. Use good occupational work practice. Observe manufacturer's storage and handling recommendations contained within this SDS. Atmosphere should be regularly checked against established exposure standards to ensure safe working conditions are maintained.
Store in original containers. Keep containers securely sealed. Store in a cool, dry, well-ventilated area. Store away from incompatible materials and foodstuff containers. Protect containers against physical damage and check regularly for leaks.
When handling, DO NOT eat, drink or smoke. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Launder contaminated clothing before re-use.
No smoking, naked lights or ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard 'physically' away from the worker and ventilation that strategically 'adds' and 'removes' air in the work environment. General exhaust is adequate under normal operating conditions.
Wear chemical protective gloves, e.g. PVC. Select gloves tested to a relevant standard (e.g. Europe EN 374, US F739, AS/NZS 2161.1 or national equivalent). When prolonged or frequently repeated contact may occur, a glove with a protection class of 5 or higher (breakthrough time greater than 240 minutes according to EN 374, AS/NZS 2161.10.1 or national equivalent) is recommended. When only brief contact is expected, a glove with a protection class of 3 or higher (breakthrough time greater than 60 minutes according to EN 374, AS/NZS 2161.10.1 or national equivalent) is recommended. For general applications, gloves with a thickness typically greater than 0.35 mm, are recommended.
Safety glasses with side shields - Chemical goggles. [AS/NZS 1337.1, EN166 or national equivalent]. Contact lenses may pose a special hazard, soft contact lenses may absorb and concentrate irritants.
Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content.
Overalls. P.V.C apron. Barrier cream. Skin cleansing cream. Wear safety footwear or safety gumboots, e.g. Rubber.
See section 12
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Unstable in the presence of incompatible materials. Product is considered stable.
See section 7.2
Hazardous polymerisation will not occur.
See section 7.2
See section 7.2
See section 5.3
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is LEYBOLD - LEYBONOL LVO 120 known by?
LEYBOLD - LEYBONOL LVO 120 is also known as: L12000; L12001; L12002; L12005; L12020
What is the hazard signal word for LEYBOLD - LEYBONOL LVO 120?
The signal word is no signal word.
What is the physical form of LEYBOLD - LEYBONOL LVO 120?
LEYBOLD - LEYBONOL LVO 120 is a liquid appearing as pale yellow liquid with a characteristic odour; immiscible with water. . It has not available odor.
What is LEYBOLD - LEYBONOL LVO 120 used for?
Compressor oil
What is the melting point of LEYBOLD - LEYBONOL LVO 120?
The melting point is <-6 °C (pour pt.) and the boiling point is >300 °C.