Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- YALE LIFT TRUCK LUBE
- Product Code
- NAY002
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Used by Spraying
Manufacturers & Suppliers
MOTIP DUPLI B.V.
manufacturer
Wolfraamweg 2, 8471 XC Wolvaga, The Netherlands
+31 (0) 561 69 44 00
Emergency Contacts
Emergency Contact
+ 31 (0) 561 69 44 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Pentane EC: 203-692-4 | 109-66-0 | 10 - 25% | Yes |
| Butane EC: 203-448-7 | 106-97-8 | 2.5 - 10% | Yes |
| Dimethyl ether EC: 204-065-8 | 115-10-8 | 10 - 25% | Yes |
| Isopropyl alcohol EC: 200-661-7 | 67-63-0 | 10 - 25% | Yes |
| Propane EC: 200-827-9 | 74-98-6 | 10 - 25% | Yes |
See Section 16 for the full text of the R Phrases declared above
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep person warm and at rest. If not breathing, if irregular breathing, or respiratory arrest occurs provide artificial respiration or oxygen by trained personnel. Give nothing by mouth. If unconscious, place in recovery position and seek medical advice.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser. Do NOT use solvents or thinners.
Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open.
If swallowed, seek medical advice immediately and show this container or label. Keep person warm and at rest. Do not induce vomiting.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
alcohol resistant foam, CO2, powders, water spray
waterjet
Fire will produce dense black smoke. Exposure to decomposition products may cause a health hazard.
Cool closed containers exposed to fire with water.
Firefighter Protection
Appropriate breathing apparatus may be required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Exclude sources of ignition and ventilate the area. Avoid breathing vapor or mist. Refer to protective measures listed in sections 7 and 8.
Do not allow to enter drains or watercourses.
Clean preferably with a detergent; avoid use of solvents.
Materials: detergent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Vapors are heavier than air and may spread along floors. Vapors may form explosive mixtures with air. Prevent the creation of flammable or explosive concentrations of vapors in air and avoid vapor concentrations higher than the occupational exposure limits. In addition, the product should be used only in areas from which all naked lights and other sources of ignition have been excluded. Keep container tightly closed. Keep away from heat, sparks and flame. No sparking tools should be used. Avoid contact with skin and eyes. Avoid the inhalation of dust, particulates and spray mist arising from the application of this preparation. Avoid inhalation of dust from sanding. Never use pressure to empty: container is not a pressure vessel. Always keep in containers made from the same material as the original one.
Store in a cool, well-ventilated area away from incompatible materials and ignition sources. Keep upright to prevent leakage.
Eating, drinking and smoking should be prohibited in area where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking.
Keep away from heat, sparks and flame. No sparking tools should be used. All naked lights and other sources of ignition have been excluded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Where reasonably practicable, this should be achieved by the use of local exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations of particulates and solvent vapors below the OEL, suitable respiratory protection must be worn.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see section 7).
strong exothermic reactions
OXIDIZING AGENTS, strong alkalis, strong acids.
carbon monoxide, carbon dioxide, smoke, oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for YALE LIFT TRUCK LUBE?
The signal word is na: r-phrases.
What is the physical form of YALE LIFT TRUCK LUBE?
YALE LIFT TRUCK LUBE is a liquid. (aerosol.) with not available. color. It has characteristic. odor.
What is the solubility of YALE LIFT TRUCK LUBE?
Insoluble in cold water, hot water.
What is YALE LIFT TRUCK LUBE used for?
Used by Spraying