Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aluminum fluoride
Product Code
449628
Chemical Name
Aluminum fluoride

Regulatory Identifiers

CAS Number
7784-18-1 Check regulations →

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV

manufacturer

Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Aluminium fluoride EC: 232-051-1 7784-18-1 90 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

First treatment with calcium gluconate paste. Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Immediate Medical Attention

Hydrofluoric (HF) acid burns require immediate and specialized first aid and medical treatment.

Medical Treatment

Skin exposures can be treated with a 2.5% calcium gluconate gel repeated until burning ceases. More serious skin exposures may require subcutaneous calcium gluconate except for digital areas unless the physician is experienced in this technique, due to the potential for tissue injury from increased pressure. Prevention of absorption of the fluoride ion in cases of ingestion can be obtained by giving milk, chewable calcium carbonate tablets or Milk of Magnesia to conscious victims.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Unsuitable media

For this substance/mixture no limitations of media extinguishing agents are given.

Specific hazards

No data available

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Take up dry. Dispose of properly. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Nitrile rubber; Break through time: 480 min; Glove thickness: 0,11 mm; Protective index: Full contact / Splash contact; Manufacturer: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Remarks: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Melting Point
1.290 °C
Relative Evaporation Rate
---
Cloud Point
---
Solubility
---
Colour
No data available
Properties Status
---
Appearance
---
Freezing Point
---
Kinematic Viscosity
No data available
Solidification Point
---
Vapor Density
---
Boiling Point
ca. 1.537 °C
Solubility In Water
0,0053 g/l (20 °C)
Upper Explosive Limit
Not applicable
Odor
odourless
Dynamic Viscosity
Not applicable
Flash Point
Not applicable
Evaporation Rate
Not applicable
Odor Threshold
Not relevant
Lower Explosive Limit
Not applicable
Physical State Data
solid
Decomposition Temperature
No data available
Softening Point
---
Explosive Limits
---
Solubility In Fat
---
Molecular Weight
83,98 g/mol
Vapor Pressure
No data available
Density
3,1 g/cm3 (25 °C)
Auto Ignition Temperature
No data available
Voc Content
---
Flammability
No data available
Bulk Density
---
Relative Density
No data available
Crystallisation Point
---
State Under Standard Conditions
---
Form
powder
Colour Intensity
---
Physical State
solid
Partition Coefficient
No data available
Metal Corrosion
---
Ph
5,9 (20 °C)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature) .

Reactivity

No data available

Hazardous reactions

No data available

Avoid

no information available

Incompatible

acids, Sodium/sodium oxides, Potassium

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Aluminum fluoride?

The signal word is no signal word.

What is the physical form of Aluminum fluoride?

Aluminum fluoride is a solid with no data available color. It has odourless odor.

What is Aluminum fluoride used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Aluminum fluoride?

The melting point is 1.290 °C and the boiling point is ca. 1.537 °C.