Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- IHC PAP pen
- Product Code
- ADI-950-233
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Uses advised against
Not for human or veterinary use.
Manufacturers & Suppliers
Enzo Biochem
manufacturer
10 Executive Blvd. FARMINGDALE, NY 11735 USA
Emergency Contacts
Emergency Contact
+1 (800) 704-9215
Emergency Contact
+1 (360) 256-7365
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| toluene EC: 203-625-9 | 108-88-3 | 25 - 50% | Yes |
| Aromatic hydrocarbons, C8-10 EC: 292-695-4 | 90989-39-2 | 25 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Open and handle receptacle with care. Keep respiratory protective device available.
Keep container tightly sealed.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1325
- Shipping Name
- FLAMMABLE SOLID, ORGANIC, N.O.S. (TOLUENE)
- Transport Class
- 4.1
- Packing Group
- II
Warning: Flammable solids, self-reactive substances, polymerizing substances and solid desensitized explosives
Warning: Flammable solids, self-reactive substances, polymerizing substances and solid desensitized explosives
Warning: Flammable solids, self-reactive substances, polymerizing substances and solid desensitized explosives
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for IHC PAP pen?
The signal word is danger.
What is the physical form of IHC PAP pen?
IHC PAP pen is a solid appearing as according to product specification with according to product specification color. It has characteristic odor.
What is IHC PAP pen used for?
Laboratory chemicals
What are the hazard statements for IHC PAP pen?
This substance has 8 hazard statements:
- H228: Flammable solid.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H340: May cause genetic defects.
- H350: May cause cancer.
- H361d: Suspected of damaging the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of IHC PAP pen?