NextSDS Logo
Safety Data Sheet EN

INDUSTRIAL CLEANER RAPID DRYING SPRAY

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INDUSTRIAL CLEANER RAPID DRYING SPRAY

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Solvent cleaner.

Manufacturers & Suppliers

R

ROCOL

manufacturer

ROCOL House, Swillington, Leeds, West Yorkshire, LS26 8BS, ENGLAND

+44 (0) 113 232 2700

Emergency Contacts

Emergency Contact

+44 (0) 113 232 2600

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

STOT SE Cat. 3 H336
Aquatic Chronic Cat. 2 H411
Eye Irrit. Cat. 2 H319
Aerosol Cat. 1 H222
Skin Irrit. Cat. 2 H315
H229

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P271 Use only outdoors or in a well-ventilated area.
P273 Avoid release to the environment.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
PROPAN-2-OL EC: 200-661-7 67-63-0 30 - 50% Yes
HYDROCARBONS C7-C9, ISOALKANES EC: 921-728-3 64741-66-8 30 - 50% Yes
CARBON DIOXIDE AEROSOL PROPELLANT EC: 204-696-9 124-38-9 3 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty from exposure ensuring one's own safety whilst doing so. Consult a doctor.

Symptoms: There may be irritation of the throat with a feeling of tightness in the chest. Exposure may cause coughing or wheezing.

Skin contact

Remove all contaminated clothes and footwear immediately unless stuck to skin. Wash immediately with plenty of soap and water.

Symptoms: There may be irritation and redness at the site of contact.

Eye contact

Bathe the eye with running water for 15 minutes. Consult a doctor.

Symptoms: There may be irritation and redness. The eyes may water profusely.

Ingestion

Wash out mouth with water. Consult a doctor.

Symptoms: There may be soreness and redness of the mouth and throat.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Suitable extinguishing media for the surrounding fire should be used.

Specific hazards

In combustion emits toxic fumes.

Instructions

Use water spray to cool containers.

Firefighter Protection

Wear self-contained breathing apparatus. Wear protective clothing to prevent contact with skin and eyes.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

If outside do not approach from downwind. If outside keep bystanders upwind and away from danger point. Mark out the contaminated area with signs and prevent access to unauthorised personnel. Turn leaking containers leak-side up to prevent the escape of liquid.

Environmental

Do not discharge into drains or rivers. Contain the spillage using bunding.

Cleanup methods

Absorb into dry earth or sand. Transfer to a closable, labelled salvage container for disposal by an appropriate method.

Materials: dry earth or sand

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid direct contact with the substance. Ensure there is sufficient ventilation of the area. Do not handle in a confined space. Avoid the formation or spread of mists in the air.

Storage

Store in a cool, well ventilated area. Keep container tightly closed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure there is sufficient ventilation of the area. The floor of the storage room must be impermeable to prevent the escape of liquids.

Hands

Protective gloves.

Eyes

Safety glasses. Ensure eye bath is to hand.

Respiratory

Self-contained breathing apparatus must be available in case of emergency.

Skin/Body

Protective clothing.

Environmental

No data available

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
---
Odor
Characteristic odour
Odor Threshold
---
Ph
---
Melting Point
<0 °C
Boiling Point
>80 °C
Flash Point
< 0°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Fast
Vapor Pressure
>4
Vapor Density
---
Relative Density
<1
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
12
Lower Explosive Limit
1
Explosive Limits
---
Auto Ignition Temperature
>200 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Not miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
710 g/l
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Non-viscous
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under recommended transport or storage conditions.

Hazardous reactions

Hazardous reactions will not occur under normal transport or storage conditions.

Avoid

Heat.

Incompatible

Strong oxidising agents. Strong acids.

Decomposition

In combustion emits toxic fumes.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS, FLAMMABLE
Transport Class
2.1
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INDUSTRIAL CLEANER RAPID DRYING SPRAY?

The signal word is danger.

What is the physical form of INDUSTRIAL CLEANER RAPID DRYING SPRAY?

INDUSTRIAL CLEANER RAPID DRYING SPRAY is a aerosol with colourless color. It has characteristic odour odor.

What is INDUSTRIAL CLEANER RAPID DRYING SPRAY used for?

Solvent cleaner.

What are the hazard statements for INDUSTRIAL CLEANER RAPID DRYING SPRAY?

This substance has 6 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of INDUSTRIAL CLEANER RAPID DRYING SPRAY?