NextSDS Logo
Safety Data Sheet EN

Solent Industrial Cleaner Rapid Dry

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Solent Industrial Cleaner Rapid Dry
Product Form
Mixture
Product Code
SOL 732-0100K

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fast drying cleaning and degreaser from metal components.

Uses advised against

Do not mix with other chemicals.

Manufacturers & Suppliers

S

Solent

Wigston, Leicester, England, LE18 2FS

+44 (0)116 288 8000

A

Action Can Ltd.

manufacturer

Dixon Close, Old Boston Trading Estate, Haydock, St. Helens, Merseyside, Wa11 9SF

01942 713667

Emergency Contacts

Emergency Contact

01942 713667

Mon – Fri: 9am to 5pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Flam. Liq.
Skin Irrit.
Aquatic Chronic

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Product as supplied: Aerosol.

Chemical Name CAS Number Concentration Hazardous
Naphtha (petroleum), hydrodesulfurized light EC: 295-434-2 92045-53-9 40 - 60% Yes
Butane EC: 203-448-7 106-97-8 30 - 40% Yes
Propan-2-ol EC: 200-661-7 67-63-0 2 - 5% Yes

For full text of R phrases see section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move person to fresh air. If symptoms persist, obtain medical attention.

Skin contact

After contact with skin, wash immediately with plenty of soap and water. If symptoms persist, obtain medical attention.

Eye contact

Hold eye open and rinse slowly and gently with water for 15-20 minutes. If symptoms persist, obtain medical attention.

Ingestion

Unlikely route of exposure.

Immediate Medical Attention

No special requirements.

Medical Treatment

Unlikely to be required but if necessary treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide.

Unsuitable media

None known.

Specific hazards

Heating may cause pressure rise with risk of bursting. This product may give rise to hazardous fumes in a fire.

Instructions

If it is safe to do so, containers should be removed from fire area because they are likely to rupture under fire conditions. Keep fire exposed containers cool by spraying with water.

Firefighter Protection

Fire fighters should wear complete protective clothing including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if safe to do so.

Environmental

Do not allow to enter drains, sewers or watercourses.

Cleanup methods

Adsorb spillages onto sand.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not spray on a naked flame or any incandescent material. Do not pierce or burn, even after use.

Storage

Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 °C.

Hygiene

Wash hands before breaks and after work.

Fire prevention

Keep away from sources of ignition - No smoking. Keep away from: Electrostatic charge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation.

Hands

Wear: Impervious gloves. Breakthrough time of the glove material: refer to the information provided by the gloves’ producer.

Eyes

Not normally required. Wear eye protection with side protection (EN166).

Respiratory

Not normally required. In case of insufficient ventilation, wear @ suitable respiratory equipment.

Environmental

Do not allow to enter drains, sewers or watercourses.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
Aerosol.
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined.
Boiling Point
Not determined.
Flash Point
-60°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
0.69
Bulk Density
---
Density
---
Flammability
Extremely flammable.
Upper Explosive Limit
8.5 Vol-%
Lower Explosive Limit
0.6 Vol-%
Explosive Limits
---
Auto Ignition Temperature
240°C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
~20% @ 20°C
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

Reacts violently with - Strong oxidising agents.

Avoid

Do not mix with other chemicals.

Incompatible

Oxidizing agent, Reducing agent.

Decomposition

This product may give rise to hazardous fumes in a fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Solent Industrial Cleaner Rapid Dry?

The signal word is na: r-phrases.

What is the physical form of Solent Industrial Cleaner Rapid Dry?

Solent Industrial Cleaner Rapid Dry is a aerosol appearing as aerosol. with colourless. color. It has characteristic. odor.

What is Solent Industrial Cleaner Rapid Dry used for?

Fast drying cleaning and degreaser from metal components.

What is the melting point of Solent Industrial Cleaner Rapid Dry?

The melting point is Not determined. and the boiling point is Not determined..