Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Loctite Super Glue Liquid
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Super glue
Manufacturers & Suppliers
Henkel Ltd
manufacturer
Adhesives, Wood Lane End, HP2 4RQ Hemel Hempstead, Great Britain
+44 (1442) 278000
https://mysds.henkel.com/index.html#/appSelection
Emergency Contacts
Emergency Contact
+44 0 8701 906777
24 Hours
Emergency Contact
+44 (0) 1606 593933
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air, consult doctor if complaint persists.
Symptoms: Irritation, coughing, shortness of breath, chest tightness.
Do not pull bonded skin apart. It may be gently peeled apart using a blunt object such as a spoon, preferably after soaking in warm soapy water. If lips are accidentally stuck together apply warm water to the lips and encourage maximum wetting and pressure from saliva inside the mouth. Peel or roll lips apart. Do not try to pull the lips apart with direct opposing action. Burns should be treated normally after the adhesive has been removed from the skin.
Symptoms: Cyanoacrylates give off heat on solidification. In rare cases a large drop will generate enough heat to cause a burn.
If the eye is bonded closed, release eyelashes with warm water by covering with wet pad. Keep eye covered until debonding is complete, usually within 1-3 days. Do not force eye open.
Symptoms: Cyanoacrylate will bond to eye protein and will cause periods of weeping which will help to debond the adhesive.
Ensure that breathing passages are not obstructed.
Symptoms: The product will polymerise immediately in the mouth making it almost impossible to swallow. Saliva will slowly separate the solidified product from the mouth (several hours).
Immediate Medical Attention
Medical advice should be sought in case solid particles of cyanoacrylate trapped behind the eyelid cause any abrasive damage.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, powder, water spray jet, fine water spray
High pressure waterjet
In the event of a fire, carbon monoxide (CO) and carbon dioxide (CO2) can be released.
Firefighter Protection
Wear self-contained breathing apparatus. Wear protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Danger of slipping on spilled product. Ensure adequate ventilation. Avoid contact with skin and eyes.
Do not empty into drains / surface water / ground water.
Remove with liquid-absorbing material
Materials: sand, peat, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Open and handle container with care. Avoid skin and eye contact.
Storage at 2 to 8°C is recommended.
Wash hands before work breaks and after finishing work. Do not eat, drink or smoke while working.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Recommended are gloves made from Nitril rubber ( Material thickness >0,1 mm, Perforation time < 30s).Gloves should be replaced after each short time contact or contamination. Available at laboratory specialized trade or at pharmacies / chemist's shops. In the case of longer contact protective gloves made from nitrile rubber are recommended according to EN 374. material thickness > 0.4 mm Perforation time > 30 minutes In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.
Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.
Suitable breathing mask when there is inadequate ventilation. Filter type: A (EN 14387) This recommendation should be matched to local conditions.
Suitable protective clothing Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Rapid exothermic polymerization will occur in the presence of water, amines, alkalis and alcohols.
See section reactivity
None if used for intended purpose.
See section reactivity.
None known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3334
- Shipping Name
- Aviation regulated liquid, n.o.s. (Cyanoacrylate ester)
- Transport Class
- 9
- Packing Group
- III
Not more than 500 ml (each inner package) - Unrestricted
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Loctite Super Glue Liquid?
The signal word is warning.
What is the physical form of Loctite Super Glue Liquid?
Loctite Super Glue Liquid is a liquid with colourless color. It has characteristic odor.
What is the solubility of Loctite Super Glue Liquid?
Polymerises in presence of water.
What is Loctite Super Glue Liquid used for?
Super glue
What are the hazard statements for Loctite Super Glue Liquid?
This substance has 3 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
What is the melting point of Loctite Super Glue Liquid?
The melting point is Not applicable, Product is a liquid and the boiling point is > 100 °C (> 212 °F).