NextSDS Logo
Lo

Loctite Super Glue Precision

WARNING liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Loctite Super Glue Precision

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Adhesive

Overview

Loctite Super Glue Precision commonly used adhesive.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P261: Avoid breathing mist/vapours.
  • P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P501: Dispose of contents/container in accordance with national regulation.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Ltd Adhesives company logo - Safety Data Sheet supplier organization

Henkel Ltd Adhesives

undefined

๐Ÿ“

Wood Lane End HP2 4RQ Hemel Hempstead Great Britain

๐ŸŒ

GB

๐Ÿ“ž

+44 (1442) 278000

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 0 8701 906777

๐ŸŒ

GB

๐Ÿ•’

24 Hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethyl 2-cyanoacrylate
EC: 230-391-5
7085-85-0 80-100% โš ๏ธ Hazardous
Bis(2-hydroxy-3-tert-butyl-5-methylphenyl)methane
EC: 204-327-1
119-47-1 0.1-0.3% โš ๏ธ Hazardous
Hydroquinone
EC: 204-617-8
123-31-9 0.01-0.1% โš ๏ธ Hazardous

Additional Information

For full text of the H - statements and other abbreviations see section 16 "Other information".

Composition Notes

Substances without classification may have community workplace exposure limits available.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air, consult doctor if complaint persists.

Symptoms:

Irritation, coughing, shortness of breath, chest tightness.

๐Ÿ–๏ธ Skin Contact

Do not pull bonded skin apart. It may be gently peeled apart using a blunt object such as a spoon, preferably after soaking in warm soapy water. If lips are accidentally stuck together apply warm water to the lips and encourage maximum wetting and pressure from saliva inside the mouth. Peel or roll lips apart. Do not try to pull the lips apart with direct opposing action. Cyanoacrylates give off heat on solidification. In rare cases a large drop will generate enough heat to cause a burn. Burns should be treated normally after the adhesive has been removed from the skin.

Symptoms:

Redness, inflammation. In rare cases a large drop will generate enough heat to cause a burn.

๐Ÿ‘๏ธ Eye Contact

If the eye is bonded closed, release eyelashes with warm water by covering with wet pad. Keep eye covered until debonding is complete, usually within 1-3 days. Cyanoacrylate will bond to eye protein and will cause periods of weeping which will help to debond the adhesive. Do not force eye open. Medical advice should be sought in case solid particles of cyanoacrylate trapped behind the eyelid cause any abrasive damage.

Symptoms:

Causes serious eye irritation.

๐Ÿฝ๏ธ Ingestion/Swallowing

Ensure that breathing passages are not obstructed. Saliva will slowly separate the solidified product from the mouth (several hours).

Symptoms:

The product will polymerise immediately in the mouth making it almost impossible to swallow.

๐Ÿšจ Immediate Medical Attention Required

In case of adverse health effects seek medical advice. Consult doctor if complaint persists (for inhalation). Medical advice should be sought in case solid particles of cyanoacrylate trapped behind the eyelid cause any abrasive damage.

Medical Treatment

Burns should be treated normally after the adhesive has been removed from the skin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
irritating
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not applicable, Product reacts with water.
๐ŸงŠ Melting Point
Not applicable, Product is a liquid
Critical Property
๐Ÿ’จ Boiling Point
> 100 ยฐC (> 212 ยฐF)
Critical Property
๐Ÿ”ฅ Flash Point
80,0 - 93 ยฐC (176 - 199.4 ยฐF); Tagliabue closed cup
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
< -50 ยฐC (< -58 ยฐF)
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
< 0,6 mbar
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,05 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
The product is not flammable.
๐Ÿ“Š Upper Explosive Limit
Not applicable, The product is not flammable.
๐Ÿ“Š Lower Explosive Limit
Not applicable, The product is not flammable.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
485 ยฐC (905 ยฐF)
๐Ÿ“Š Decomposition Temperature
Not applicable, Substance/mixture is not self-reactive, no organic peroxide and does not decompose under foreseen conditions of use
๐Ÿ’ง Solubility
Polymerizes on contact with water.
๐Ÿ“Š Partition Coefficient
Currently under determination
๐Ÿ“Š Solubility In Water
Polymerizes on contact with water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
60,00 - 80,00 mPa.s
๐Ÿ“Š Kinematic Viscosity
45 - 275 mm2/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Recommended are gloves made from Nitril rubber ( Material thickness >0,1 mm, Perforation time < 30s).Gloves should be replaced after each short time contact or contamination. Available at laboratory specialized trade or at pharmacies / chemist's shops. In the case of longer contact protective gloves made from nitrile rubber are recommended according to EN 374. material thickness > 0.4 mm Perforation time > 30 minutes In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.

๐Ÿ‘๏ธ Eye Protection

Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.

๐Ÿ˜ท Respiratory Protection

Suitable breathing mask when there is inadequate ventilation. Combination filter: ABEKP (EN 14387) This recommendation should be matched to local conditions.

๐Ÿฆบ Skin/Body Protection

Suitable protective clothing Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3334

๐Ÿ“ฆ Proper Shipping Name

Aviation regulated liquid, n.o.s. (Ethyl cyanoacrylate)

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Loctite Super Glue Precision?

The signal word for this substance is "warning".

What is the physical form of Loctite Super Glue Precision?

Loctite Super Glue Precision is a liquid with colourless color. It has irritating odor.

What is the solubility of Loctite Super Glue Precision?

Polymerizes on contact with water.

What is Loctite Super Glue Precision used for?

Adhesive

What are the hazard statements for Loctite Super Glue Precision?

This substance has 3 hazard statements: H315: Causes skin irritation. H319: Causes serious eye irritation. H335: May cause respiratory irritation.

What is the melting point of Loctite Super Glue Precision?

The melting point is Not applicable, Product is a liquid and the boiling point is > 100 ยฐC (> 212 ยฐF).