Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Coal slag
- Product Form
- Substance
- Chemical Name
- Coal slag
- Synonyms
- Boiler slag, Slag, coal slag, slag granules, Coal furnace slag
Regulatory Identifiers
- CAS Number
- 68131-74-8 Check regulations →
- EC Number
- 931-322-8 Check regulations →
- REACH No.
- 01-2119491179-27-0235
Identified Uses
Use as an abrasive, roofing grit, decorative grit in concrete products, raw material for producers of concrete and structural clay products, and anti-slip grit.
Uses advised against
This product must not be used in applications other than those identified above, without first seeking advice of the supplier
Manufacturers & Suppliers
EP Power Grit GmbH
manufacturer
Duisburger Straße 170, 46535 Dinslaken - Germany
+49 (0) 2306 37301-90
Emergency Contacts
Emergency Contact
+49 (0) 2306 37301-90
during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Vitreous/amorphous components and minerals. The main elements are Al2O3, Fe2O3, CaO and SiO2
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ashes (residues), coal EC: 931-322-8 | 68131-74-8 | 99% | No |
| Quartz (fine fraction) EC: 238-878-4 | 14808-60-7 | 1% | Yes |
Notes
Substance containing a main component
First Aid Measures
Emergency procedures for chemical exposure incidents
Move the affected person away from the contaminated area and into the fresh air.
No special first aid measures necessary.
Rinse with copious quantities of water and seek medical attention if irritation persists.
No first aid measure required.
Immediate Medical Attention
No special first aid measures necessary.
Medical Treatment
No special first aid measures necessary.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific extinguishing media is needed.
No restriction on the extinguishing media to be used.
Fire hazard: Not combustible.
Firefighter Protection
No specific fire-fighting protection is required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special requirements.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid airborne dust generation. Handle packaged products carefully to prevent accidental bursting. If you require advice on safe handling techniques, please contact your supplier.
Keep containers closed and store packaged products so as to prevent accidental bursting.
Do not eat, drink and smoke in work areas; wash hands after use; remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Minimise airborne dust generation. Use process enclosures, local exhaust ventilation or other engineering controls to keep airborne levels below specified exposure limits. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne particles below the exposure limit. Apply organisational measures, e.g. by isolating personnel from dusty areas.
Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin. Wash hands at the end of each work session.
Wear safety glasses with side-shields in circumstances where there is a risk of penetrative eye injuries.
In case of prolonged exposure to airborne dust concentrations, wear a respiratory protective equipment that complies with the requirements of European or national legislation. The use of half or full face masks with filters against particles of category 2 or 3 (FP2 - FP3) is recommended. See EN 143: 2021 - Respiratory protective devices. Particle filters
No specific requirement. Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin.
Avoid wind dispersal.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable.
Inert, not reactive.
No hazardous reactions.
Not relevant.
No particular incompatibility.
Not relevant.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Coal slag known by?
Coal slag is also known as: Boiler slag, Slag, coal slag, slag granules, Coal furnace slag
What is the hazard signal word for Coal slag?
The signal word is no signal word.
What is the physical form of Coal slag?
Coal slag is a solid appearing as granules, grain shape: angular, sharp-edged, glassy with grey-dark brown, black color. It has odourless odor.
What is the solubility of Coal slag?
Water: Insoluble
What is Coal slag used for?
Use as an abrasive, roofing grit, decorative grit in concrete products, raw material for producers of concrete and structural clay products, and anti-slip grit.
What is the melting point of Coal slag?
The melting point is > 1260 °C and the boiling point is > 2000 °C.