Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Silicone Spray
- Product Code
- RL2R,RL2RU,72476051100,HMTN0301A,HMTN0801A,72076039001,72476010022
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Car maintenance product.
Manufacturers & Suppliers
Holt Lloyd International Ltd
manufacturer
Barton Dock Road, Stretford, Manchester, M32 0YQ - England, UK
+44 (0) 161 866 4800
http://www.holtsauto.com
Emergency Contacts
Emergency Contact
00 44 (0) 161 866 4800
0900 - 1700 hrs
Emergency Contact
020 7358 9167
Out of office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| DISTILLATES (PETROLEUM), HYDROTREATED LIGHT; KEROSINE - UNSPECIFIED EC: 265-149-8 | 64742-47-8 | 60 - 100% | Yes |
| BUTANE EC: 203-448-7 | 106-97-8 | 10 - 30% | Yes |
| ISOBUTANE EC: 200-857-2 | 75-28-5 | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move affected person to fresh air at once. When breathing is difficult, properly trained personnel may assist affected person by administering oxygen. Keep affected person warm and at rest. Get medical attention immediately.
Wash skin thoroughly with soap and water. Get medical attention if any discomfort continues.
If liquid has entered the eyes, proceed as follows. Remove any contact lenses and open eyelids wide apart. Continue to rinse for at least 15 minutes. Continue to rinse for at least 15 minutes. Get medical attention if any discomfort continues.
Not relevant.
Immediate Medical Attention
Get medical attention immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguish with the following media: Powder. Dry chemicals, sand, dolomite etc. Water spray, fog or mist.
Risk of explosion if heated. Containers can burst violently or explode when heated, due to excessive pressure build-up.
Containers close to fire should be removed or cooled with water. Use water to keep fire exposed containers cool and disperse vapours.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear suitable protective equipment, including gloves, goggles/face shield, respirator, boots, clothing or apron, as appropriate. Eliminate all sources of ignition. No smoking, sparks, flames or other sources of ignition near spillage. Provide adequate ventilation. Wear protective clothing as described in Section 8 of this safety data sheet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat, sparks and open flame. Avoid spilling. Avoid contact with skin and eyes. Avoid inhalation of vapours. Use approved respirator if air contamination is above an acceptable level.
Aerosol cans: Must not be exposed to direct sunlight or temperatures above 50°C.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation.
Chemical-resistant, impervious gloves complying with an approved standard should be worn if a risk assessment indicates skin contact is possible. It is recommended that gloves are made of the following material: Rubber (natural, latex). EN374
Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible. The following protection should be worn: Chemical splash goggles or face shield.
No specific recommendations. Respiratory protection must be used if the airborne contamination exceeds the recommended occupational exposure limit.
Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal ambient temperatures.
Avoid heat, flames and other sources of ignition.
Strong oxidising agents. Strong alkalis. Strong mineral acids.
Fire creates: Vapours/gases/fumes of: Carbon monoxide (CO). Carbon dioxide (CO2).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Silicone Spray?
The signal word is danger.
What is the physical form of Silicone Spray?
Silicone Spray is a aerosol appearing as aerosol. .
What is Silicone Spray used for?
Car maintenance product.
What are the hazard statements for Silicone Spray?
This substance has 2 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: may burst if heated