NextSDS Logo
An

Antifreeze/Coolant HT-FVA

WARNING Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Antifreeze/Coolant HT-FVA
Product Form
Mixture
Product Code
Ford Internal Ref .: 505849

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
DEX5-QFEF-A100-06EK

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Antifreeze
Uses Advised Against
None known

Overview

Antifreeze/Coolant HT-FVA commonly used antifreeze.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning

Hazard Classifications

Acute Tox. Category 4 H302
STOT RE Category 2 H373

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

  • P264: Wash hands thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P301+P312: IF SWALLOWED: Call doctor, a POISON CENTER if you feel unwell.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ford-Werke GmbH

undefined

๐Ÿ“

Edsel-Ford-Str. 2-14 50769 Cologne Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 221 90-33333

Ford Motor Company Ltd.

distributor

๐Ÿ“

Parts Distribution Centre Royal Oak Way South NN11 8NT Daventry, Northants United Kingdom

๐ŸŒ

GB

๐Ÿ“ž

+44 1327 305 198

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

GBK GmbH

๐Ÿ“ž

+49 (0) 6132-84463

๐ŸŒ

DE

๐Ÿ•’

24/7

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethanediol
EC: 203-473-3
107-21-1 90-100% โš ๏ธ Hazardous
Disodium sebacate
EC: 241-300-3
17265-14-4 1-10% โš ๏ธ Hazardous
Methyl-1H-benzotriazole
EC: 249-596-6
29385-43-1 0.1-0.25% โš ๏ธ Hazardous

Additional Information

Full text of H- and EUH-statements: see section 16

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention.

๐Ÿ–๏ธ Skin Contact

Take off immediately all contaminated clothing and wash it before reuse. Wash immediately with plenty of water. Get medical advice/attention.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately and thoroughly, pulling the eyelids well away from the eye (15 minutes minimum). Remove contact lenses, if present and easy to do. Continue rinsing. Call a physician immediately.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. Rinse mouth thoroughly. Get immediate medical advice/attention.

Symptoms:

May cause damage to organs (kidneys) (oral). Harmful if swallowed.

๐Ÿšจ Immediate Medical Attention Required

Get medical advice/attention immediately. Call a physician immediately.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Purple.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
8.4 100%
๐ŸงŠ Melting Point
Not available
Critical Property
๐Ÿ’จ Boiling Point
> 170
Critical Property
๐Ÿ”ฅ Flash Point
> 110
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
0.2 hPa @ 20
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.125 g/cm3 @ 20
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Miscible (in all proportions) with : water.
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Miscible (in all proportions) with : water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
92 %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
20-30 mm2/s @ 20
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

๐Ÿงค Hand Protection

Protective gloves. EN 374. The recommendation is only valid for the supplied product and the stated application. Special working conditions, like heat or mechanical strain, which deviate from the test conditions, can reduce the protective effect provided by the recommended glove. Material: Nitrile rubber (NBR), Permeation: 6 (> 480 minutes), Thickness (mm): 0,4, Comments: Glove recommendation: Camatril Velours 730 (Kchele-Cama GmbH, source of supply see www.kcl.de) or comparable product. In case of splash contact: Nitrile rubber (NBR), Permeation: 6 (> 480 minutes), Thickness (mm): 0,4, Comments: Glove recommendation: Camatril Velours 730 (Kchele-Cama GmbH, source of supply see www.kcl.de) or comparable product.

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields. EN 166.

๐Ÿ˜ท Respiratory Protection

If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn. Extra personal protection: A/P2 filter respirator for organic vapour and harmful dust

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing. Long sleeved protective clothing. EN 14605. EN ISO 13982. Personal protective equipment should be chosen according to the CEN standards and in discussion with the supplier of the protective equipment.

๐ŸŒ Environmental Exposure Controls

Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all environmental releases.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Antifreeze/Coolant HT-FVA?

The signal word for this substance is "warning".

What is the physical form of Antifreeze/Coolant HT-FVA?

Antifreeze/Coolant HT-FVA is a liquid with purple. color. It has characteristic. odor.

What is the solubility of Antifreeze/Coolant HT-FVA?

Miscible (in all proportions) with : water.

What is Antifreeze/Coolant HT-FVA used for?

Antifreeze

What are the hazard statements for Antifreeze/Coolant HT-FVA?

This substance has 2 hazard statements: H302: Harmful if swallowed. H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Antifreeze/Coolant HT-FVA?

The melting point is Not available and the boiling point is > 170.