Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Kelfort ® SIL-NO 310ML
- Product Form
- Mixture
- Product Code
- 1516251-1516260
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Sealant
Uses advised against
None known.
Manufacturers & Suppliers
Ferney Group BV
distributor
Postbus 24 1700 AA Heerhugowaard – The Netherlands
+31 (0)72-5765000
http://www.ferney.nl
Emergency Contacts
Emergency Contact
+49(0)9366-907126
ma-do 7.15-18.00 hour
Emergency Contact
+31(0)88-7558000
National Poisons Information Center
+31 88 755 80 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-Pentandione, 0,0',0"-(methyisilylidyne)trioxime EC: 484-460-1 | 37859-55-5 | 1 - 2.5% | Yes |
| 3-aminopropyltriethoxysilane EC: 213-048-4 | --- | 0.1 - 1% | Yes |
| Octamethylcyclotetrasiloxane [D4] EC: 209-136-7 | 556-67-2 | 0.01 - 0.1% | Yes |
| 2-octyl-2H-isothiazol-3-one [OIT] EC: 247-761-7 | 26530-20-1 | 0.0015 - 0.01% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If symptoms persist, call a doctor.
In the case of skin irritation or allergic reactions see a doctor. Wash skin with soap and water.
Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Consult an ophthalmologist.
Never give anything by mouth to an unconscious person. Rinse mouth thoroughly with water. Drink 1 or 2 glasses of water. Do NOT induce vomiting.
Medical Treatment
Small amounts of methanol (CAS 67-56-1) are formed by hydrolysis and released, when the product is exposed to moisture or water. Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
Full water jet.
Thermal decomposition can lead to release of irritating gases and vapours.
Firefighter Protection
Wear self contained breathing apparatus for fire fighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not get in eyes, on skin, or on clothing. Use personal protective equipment as required. Ensure adequate ventilation.
Prevent product from entering drains. Do not allow to enter into soil/subsoil. See Section 12 for additional Ecological Information.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure adequate ventilation.
Protect from moisture. Keep away from food, drink and animal feedingstuffs.
Do not eat, drink or smoke when using this product. Wash hands before breaks and after work. Take off all contaminated clothing and wash it before reuse.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Wear suitable gloves. Recommended Use:. Neoprene™. Nitrile rubber. Butyl rubber. Glove thickness > 0.7mm. The breakthrough time for the mentioned glove material is in general greater than 480 min. Ensure that the breakthrough time of the glove material is not exceeded. Refer to glove supplier for information on breakthrough time for specific gloves. Gloves must conform to standard EN 374
Wear safety glasses with side shields (or goggles). Eye protection must conform to standard EN 166.
In case of inadequate ventilation wear respiratory protection. Wear a respirator conforming to EN 140 with Type A/P2 filter or better. Recommended filter type: Organic gases and vapours filter conforming to EN 14387. White. Brown.
None under normal use conditions.
Do not allow uncontrolled discharge of product into the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Product cures with moisture.
None under normal processing.
Product cures with moisture. Protect from moisture. Exposure to air or moisture over prolonged periods. Do not freeze. Keep away from open flames, hot surfaces and sources of ignition.
Strong oxidising agents.
Small amounts of methanol (CAS 67-56-1) are formed by hydrolysis and released upon curing. Small amounts of ethanol (CAS 64-17-5) are formed by hydrolysis and released upon curing.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Kelfort ® SIL-NO 310ML?
The signal word is no signal word.
What is the physical form of Kelfort ® SIL-NO 310ML?
Kelfort ® SIL-NO 310ML is a solid appearing as paste with see section 1 for more information color. It has characteristic. odor.
What is Kelfort ® SIL-NO 310ML used for?
Sealant
What are the hazard statements for Kelfort ® SIL-NO 310ML?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Kelfort ® SIL-NO 310ML?
The melting point is No data available and the boiling point is No data available.