NextSDS Logo
Safety Data Sheet EN

Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur

CAS 14459-95-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
Product Code
1.04984

Regulatory Identifiers

CAS Number
14459-95-1 Check regulations →

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Merck Life Science BV

manufacturer

Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
14459-95-1 14459-95-1 --- No

Notes

No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Fire may cause evolution of: Hydrogen cyanide (hydrocyanic acid), nitrous gases. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.

Storage

Protected from light. Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Nitrile rubber; Break through time : 480 min; Glove thickness : 0,11 mm; Protective index : Full contact; Manufacturer : KCL 741 Dermatril® L; Material : Nitrile rubber; Break through time : 480 min; Glove thickness : 0,11 mm; Protective index : Splash contact; Manufacturer : KCL 741 Dermatril® L; Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: : Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
light yellow
Colour Intensity
---
Form
crystalline
Odor
odourless
Odor Threshold
Not applicable
Ph
8,0 - 10 (25 °C)
Melting Point
70 °C
Boiling Point
No data available
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
ca. 950 - 1.050 kg/m3
Density
1,85 g/cm3 (20 °C) (anhydrous substance)
Flammability
The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
> 70 °C
Solubility
---
Partition Coefficient
Not applicable for inorganic substances
Solubility In Water
211 g/l (20 °C)
Solubility In Fat
---
Molecular Weight
422,39 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Contact with acids liberates very toxic gas.

Hazardous reactions

A risk of explosion and/or of toxic gas formation exists with the following substances: Strong acids, Oxidizing agents, Hydrogen chloride gas, nitrites

Avoid

Avoid temperatures above 60°C, direct sunlight and contact with sources of heat. Contact with acids liberates very toxic gas.

Incompatible

acids

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The signal word is no signal word.

What is the physical form of Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a solid with light yellow color. It has odourless odor.

What is Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?

Reagent for analysis

What is the melting point of Potassium hexacyanoferrate(II) trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The melting point is 70 °C and the boiling point is No data available.