Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur
- Product Code
- 105082
Regulatory Identifiers
- CAS Number
- 7722-64-7 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Reagent for analysis, Chemical production
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Potassium permanganate EC: 231-760-3 | 7722-64-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air.
Symptoms: Cough, Shortness of breath
Wash off with plenty of water. Remove contaminated clothing.
Symptoms: Irritation and corrosion
Rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.
Symptoms: Risk of corneal clouding.
Immediately make victim drink water (two glasses at most). Consult a physician.
Symptoms: Nausea, Vomiting
Immediate Medical Attention
Call in ophthalmologist if necessary. Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Has a fire-promoting effect due to release of oxygen. Ambient fire may liberate hazardous vapours.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid substance contact. Avoid inhalation of dusts. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not empty into drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Potassium dichromate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-50-9
Potassium sulfate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-80-5
Potassium iodate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7758-05-6
Potassium peroxodisulfate for analysis EMSURE®
CAS: 7727-21-1
Potassium nitrate for analysis EMSURE® ISO,Reag. Ph Eur
CAS: 7757-79-1
Potassium nitrate for analysis EMSURE® ISO,Reag. Ph Eur
CAS: 7757-79-1
Potassium bromate for analysis (max 0,000001% Hg) EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7758-01-2
Potassium sodium tartrate tetrahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6381-59-5
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Tightly closed. Dry. Do not store near combustible materials.
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.
Do not store near combustible materials.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Safety glasses
required when dusts are generated. Empfohlener Filtertyp: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not empty into drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
strong oxidising agent
Risk of explosion with: powdered aluminium, Ammonia, AMMONIUM NITRATE, ammonium compounds, arsenic, Chlorine, Dimethylformamide, acetic acid, Acetic anhydride, formaldehyde, oxidisable substances, Nitro compounds, phosphorus, pyridine, strong reducing agents, hydrochloric acid, sulfur, Titanium, sugars, Alcohols (with sulphuric acid), alkali salts (with sulphuric acid). Risk of ignition or formation of inflammable gases or vapours with: Acetaldehyde, Acetone, Alcohols, antimony, Aldehydes, Combustible Liquids, silanes, dimethyl sulfoxide, Ethylene glycol, ethanol, Hydrogen fluoride, organic solvent, glycerol, hydroxylamine, CARBON, mineral acids, Organic Substances, oxalic acid, sulphuric acid, hydrogen sulphide, Triethylamine, hydrogen peroxide, glycerol (with sulphuric acid), sulphuric acid (with Organic Substances).
Strong heating (decomposition).
no information available
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1490
- Shipping Name
- POTASSIUM PERMANGANATE
- Transport Class
- 5.1
- Packing Group
- II
yes
yes
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur?
The signal word is danger.
What is the physical form of Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur?
Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur is a solid with violet color. It has odourless odor.
What is Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur used for?
Reagent for analysis, Chemical production
What are the hazard statements for Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur?
This substance has 3 hazard statements:
- H272: May intensify fire; oxidiser.
- H302: Harmful if swallowed.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Potassium permanganate for analysis EMSURE® ACS,Reag. Ph Eur?
The melting point is > 240 °C (decomposition) and the boiling point is No information available..