Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Silica gel C 2-6 mm Chameleon® granules with moisture indicator
- Product Code
- 83000
Regulatory Identifiers
- CAS Number
- Not applicable Check regulations →
Identified Uses
General chemical reagent
Uses advised against
The product, as such or as a component of a mixture, is not intended to be used by consumers (as defined by the REACH Regulation).
Manufacturers & Suppliers
VWR International Ltd.
national supplier
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN, UK
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ammonium iron (III) sulphate dodecahydrate EC: 616-517-5 | 7783-83-7 | 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. Obtain medical attention if symptoms appear.
Gently wash with plenty of soap and water. In case of skin reactions, consult a physician.
Rinse immediately carefully and thoroughly with eye-bath or water. Obtain medical attention if symptoms appear.
Rinse mouth thoroughly with water. Call a doctor if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. Co-ordinate fire-fighting measures to the fire surroundings.
Full water jet.
In case of fire may be liberated: Pyrolysis products, toxic
Use water spray jet to protect personnel and to cool endangered containers.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing. Do not breathe smoke.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove victim out of the danger area. First Aid, decontamination, treatment of symptoms.
No special environmental measures are necessary.
Take up mechanically, placing in appropriate containers for disposal.
Materials: appropriate containers
Related Products
Similar products with comparable safety profiles
Silica gel
CAS: 112926-00-8
Silica gel
CAS: 7631-86-9
Silica gel beads, desiccant ~ 2 - 5 mm
CAS: 7631-86-9
Silica gel orange
CAS: 112926-00-8
Silica gel 60 (0.063-0.200 mm) for column chromatography (70-230 mesh ASTM)
CAS: 7631-86-9
Silica gel FIA coarse 0,071-0,63 mm, 1
---
LLG-Desiccant beads 1 to 3 mm orange self-indicating gel
---
LLG-Desiccant beads 1 to 3 mm orange self-indicating gel
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands before breaks and after work. Avoid contact with eyes and skin. When using do not eat, drink or smoke. Provide eye shower and label its location conspicuously.
Store in a well-ventilated place. Keep container tightly closed.
Wash hands before breaks and after work. Avoid contact with eyes and skin. When using do not eat, drink or smoke.
No special measures are necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374. In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,12 mm, Breakthrough time: > 480 min, Recommended glove articles: VWR 112-0998.
Eye glasses with side protection DIN-/EN-Norms EN 166. Recommendation: VWR 111-0432
Usually no personal respirative protection necessary.
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
This material is non-reactive under normal conditions.
No information available.
Keep away from sources of heat (e.g. hot surfaces), sparks and open flames.
No further relevant information available.
No known hazardous decomposition products. Decomposition products in case of fire: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Silica gel C 2-6 mm Chameleon® granules with moisture indicator?
The signal word is no signal word.
What is the physical form of Silica gel C 2-6 mm Chameleon® granules with moisture indicator?
Silica gel C 2-6 mm Chameleon® granules with moisture indicator is a solid with orange color. It has odourless odor.
What is Silica gel C 2-6 mm Chameleon® granules with moisture indicator used for?
General chemical reagent
What is the melting point of Silica gel C 2-6 mm Chameleon® granules with moisture indicator?
The melting point is >1000 °C and the boiling point is no data available.