NextSDS Logo
Safety Data Sheet EN

MicroVue™ SC5b-9 Plus EIA

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MicroVue™ SC5b-9 Plus EIA
Product Form
Mixture
Product Code
A020, A029

Regulatory Identifiers

CAS Number
N/A

Identified Uses

A020 For research use only in the United States. A029 For in vitro diagnostic use. Not for sale in the United States or Canada.

Uses advised against

Restricted to professional users.

Manufacturers & Suppliers

Ortho-Clinical Diagnostics, Inc. logo

Ortho-Clinical Diagnostics, Inc.

manufacturer

2005 East State Street, Suite 100 Athens, OH, 45701 U.S.A.

1.800.874.1517

https://techdocs.quidelortho.com

Emergency Contacts

Emergency Contact

1.866.519.4752

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317
Aquatic Acute Cat. 3 H402
Skin Sens. Cat. 1 H317
Skin Corr. Cat. 1A H314
Eye Dam. Cat. 1 H318
Aquatic Acute Cat. 3 H402
Flam. Liq. Cat. 2 H225
Eye Irrit. Cat. 2A H319
Repr. Cat. 1B H360
STOT RE Cat. 2 H373

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor
H314 Causes severe skin burns and eye damage
H317 May cause an allergic skin reaction
H319 Causes serious eye irritation
H360 May damage fertility or the unborn child
H373 May cause damage to organs through prolonged or repeated exposure
H402 Harmful to aquatic life

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P260 Do not breathe dust, fume, gas, mist, vapors, spray.
P264 Wash hands, forearms and face thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P272 Contaminated work clothing must not be allowed out of the workplace.
P273 Avoid release to the environment.
P280 Wear gloves, safety glasses, and lab coat.
P302 + P352 If on skin: Wash skin thoroughly with mild soap and water
P304 + P340 If inhaled: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314 Get medical advice or attention if you feel unwell.
P321 Specific treatment: Seek medical attention if ill effect develops.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents and/or container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
5-Chloro-2-methyl-3(2H)-isothiazolone, mixture with 2-methyl-3(2H)-isothiazolone 55965-84-9 0.035% Yes
tetrasodium ethylenediaminetetracetate, dihydrate 10378-23-1 1% Yes
5-Chloro-2-methyl-3(2H)-isothiazolone, mixture with 2-methyl-3(2H)-isothiazolone 55965-84-9 0.001% Yes
Hydrochloric Acid 7647-01-0 3.653% Yes
2-Pyrrolidinone, 1-ethyl- 2687-91-4 1 - 5% Yes
1-Methyl-2-pyrrolidone 872-50-4 1 - 5% Yes
Acetone 67-64-1 1 - 10% Yes
1H-imidazole 288-32-4 0.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor/physician if you feel unwell.

Symptoms: May cause respiratory irritation.

Skin contact

Wash skin with plenty of water. Take off contaminated clothing. If skin irritation or rash occurs: Get medical advice/attention.

Symptoms: Irritation. May cause an allergic skin reaction.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a physician immediately.

Symptoms: Serious damage to eyes.

Ingestion

Call a poison center/doctor/physician if you feel unwell.

Immediate Medical Attention

Call a poison center/doctor/physician if you feel unwell.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Dry powder. Foam. Carbon dioxide.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Only qualified personnel equipped with suitable protective equipment may intervene. Do not breathe dust/fume/gas/mist/vapors/spray.

Environmental

Avoid release to the environment.

Cleanup methods

Take up liquid spill into absorbent material.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear personal protective equipment. Do not breathe dust/fume/gas/mist/vapors/spray. Use only outdoors or in a well-ventilated area. Avoid contact with skin and eyes.

Storage

Store in a well-ventilated place. Keep container tightly closed. Keep cool.

Hygiene

Separate working clothes from town clothes. Launder separately. Wash contaminated clothing before reuse. Contaminated work clothing should not be allowed out of the workplace. Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Cloud Point
---
Flammability
Not applicable.
Ph
Stop Solution pH <1, 20X Wash Solution pH 6.1 to 6.6, Complement Diluent, TMB Substrate – Neutral.
Properties Status
---
Kinematic Viscosity
No data available
Vapor Pressure
No data available
Relative Density
No data available
Melting Point
Not applicable
Colour Intensity
---
Relative Evaporation Rate
---
Dynamic Viscosity
---
Softening Point
---
Form
---
State Under Standard Conditions
---
Evaporation Rate
---
Solubility In Water
---
Auto Ignition Temperature
No data available
Bulk Density
---
Physical State Data
liquid
Partition Coefficient
No data available
Lower Explosive Limit
No data available
Density
---
Physical State
Liquid
Vapor Density
---
Upper Explosive Limit
No data available
Crystallisation Point
---
Freezing Point
No data available
Explosive Limits
---
Boiling Point
No data available
Flash Point
No data available
Decomposition Temperature
No data available
Metal Corrosion
---
Odor Threshold
No data available
Solubility
No data available
Solubility In Fat
---
Voc Content
---
Odor
20X Wash Concentrate, Complement Diluent – Odourless, Stop Solution, TMB Substrate – Mild odour.
Appearance
EIA Kit.
Colour
Clear to slightly brown
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

None under recommended storage and handling conditions (see section 7).

Incompatible

No additional information available

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1090
Shipping Name
Acetone Solution
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MicroVue™ SC5b-9 Plus EIA?

The signal word is danger.

What is the physical form of MicroVue™ SC5b-9 Plus EIA?

MicroVue™ SC5b-9 Plus EIA is a liquid appearing as eia kit. with clear to slightly brown color. It has 20x wash concentrate, complement diluent – odourless, stop solution, tmb substrate – mild odour. odor.

What is the solubility of MicroVue™ SC5b-9 Plus EIA?

No data available

What is MicroVue™ SC5b-9 Plus EIA used for?

A020 For research use only in the United States. A029 For in vitro diagnostic use. Not for sale in the United States or Canada.

What are the hazard statements for MicroVue™ SC5b-9 Plus EIA?

This substance has 7 hazard statements:

  • H225: Highly flammable liquid and vapor
  • H314: Causes severe skin burns and eye damage
  • H317: May cause an allergic skin reaction
  • H319: Causes serious eye irritation
  • H360: May damage fertility or the unborn child
  • H373: May cause damage to organs through prolonged or repeated exposure
  • H402: Harmful to aquatic life

What is the melting point of MicroVue™ SC5b-9 Plus EIA?

The melting point is Not applicable and the boiling point is No data available.