Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur
- Product Code
- 100983
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis Chemical production
Manufacturers & Suppliers
EMD Millipore Corporation
manufacturer
290 Concord Road, Billerica, MA 01821, United States of America
+1-978-751-4321
Emergency Contacts
CANUTEC
613-996-6666
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol | 64-17-5 | 90 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
wash off with plenty of water. Remove contaminated clothing.
rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.
immediately make victim drink water (two glasses at most). Consult doctor in the event of any complaints. Never give anything by mouth to an unconscious person.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2), Foam, Dry powder, Water
For this substance/mixture no limitations of extinguishing agents are given.
Combustible material, Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air at ambient temperatures. Pay attention to flashback.
Remove container from danger zone and cool with water.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area, observe emergency procedures, consult an expert.
Do not empty into drains. Risk of explosion.
Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Storage temperature: no restrictions.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Recommended: full contact: Glove material: butyl-rubber Glove thickness: 0.7 mm Break through time: > 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0.40 mm Break through time: > 120 min
Safety glasses
required when vapors/aerosols are generated. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Protective clothing should be selected specifically for the workplace, depending on concentration and quantity of the hazardous substances handled. The chemical resistance of the protective equipment should be inquired at the respective supplier. Other protective equipment: Flame retardant antistatic protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapors may form explosive mixture with air.
Risk of explosion with:, Risk of ignition or formation of inflammable gases or vapors with: chromium(VI) oxide, hydrogen peroxide, uranium hexafluoride, nitrogen dioxide, Nitric acid, Oxides of phosphorus, permanganic acid, perchloric acid, sulfuric acid, potassium permanganate, perchlorates, Fluorine, Ethylene oxide, chromyl chloride, halogen-halogen compounds, Strong oxidizing agents, alkali oxides, Alkaline earth metals, Alkali metals
Warming. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
rubber, various plastics
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Toxicity
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The information presented only applies to the material as supplied. The identification based on characteristic(s) or listing may not apply if the material has been used or otherwise contaminated. It is the responsibility of the waste generator to determine the toxicity and physical properties of the material generated to determine the proper waste identification and disposal methods in compliance with applicable regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1170
- Shipping Name
- ETHANOL
- Transport Class
- 3
- Packing Group
- II
yes
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur?
The signal word is danger.
What is the physical form of Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur?
Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur is a liquid with colorless color. It has alcohol-like odor.
What is Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur used for?
Reagent for analysis Chemical production
What are the hazard statements for Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur?
This substance has 1 hazard statement:
- H225: Highly flammable liquid and vapor.
What is the melting point of Ethanol absolute for analysis EMSURE® ACS, ISO, Reag. Ph Eur?
The melting point is -174.1 °F (-114.5 °C) and the boiling point is 172.9 °F (78.3 °C) at 1,013 hPa.