Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FF ZF EV ECOFLUID E WOA
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Motor oil
Manufacturers & Suppliers
TotalEnergies Lubrifiants
manufacturer
562 Avenue du Parc de L'ile 92029 Nanterre Cedex FRANCE
+33 (0)1 41 35 40 00
Emergency Contacts
France - ORFILA (INRS)
+33 (0)1 45 42 59 59
ANGERS
02 41 48 21 21
BORDEAUX
05 56 96 40 80
LILLE
08 00 59 59 59
LYON
04 72 11 69 11
MARSEILLE
04 91 75 25 25
NANCY
03 83 22 50 50
PARIS
01 40 05 48 48
TOULOUSE
05 61 77 74 47
Emergency Contact
+44 1235 239670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 50 - 75% | Yes |
| mineral oil | --- | 10% | Yes |
| Reaction Products of Diphosphorus Pentaoxide with Alcohols, C14-18 even, salted with Amines, C12-14, Tert-alkyl EC: 943-540-0 | --- | 1.3% | Yes |
| Reaction products of diphenylamine with nonene, branched EC: 701-385-4 | --- | 1% | Yes |
| N,N-bis(2-ethylhexyl)-((1,2,4-triazol-1-yl)methyl) amine EC: 401-280-0 | 91273-04-0 | 0.1% | Yes |
Mineral oil of petroleum origin. Product containing mineral oil with less than 3% DMSO extract as measured by IP 346. The product is made from synthetic base oils
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes.
Symptoms: Irritation, redness, dryness, cracking
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses.
Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel.
Immediate Medical Attention
Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container. Contain and collect spillage with non-combustible, absorbent material.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). See Section 10 for incompatible materials before handling or use.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves. Fluorinated rubber. nitrile rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with ISO 21420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0,38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency.
In case of contact through splashing: safety glasses with side-shields, EN 166.
None under normal use conditions. If these are not sufficient to maintain exposure below the OEL, suitable respiratory protection must be worn (Type A/P1).
Wear work clothing with long sleeves. Non-skid safety shoes or boots
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
No specific data.
Strong oxidizing agents
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
Results of PMT and vPvM assessment
12.5 Results of PBT and vPvB assessment
The product does not meet the criteria to be considered as a PBT or vPvB.
12.6 Endocrine disrupting properties
12.7 Other adverse effects
No known significant effects or critical hazards.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The information stated in this section relates solely to the conformity of the chemical product with the countries Inventories. Other regulations may apply for importation or marketing authorizations.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FF ZF EV ECOFLUID E WOA?
The signal word is no signal word.
What is the physical form of FF ZF EV ECOFLUID E WOA?
FF ZF EV ECOFLUID E WOA is a liquid. with yellow. color. It has characteristic. odor.
What is FF ZF EV ECOFLUID E WOA used for?
Motor oil
What is the melting point of FF ZF EV ECOFLUID E WOA?
The melting point is Technically not possible to measure and the boiling point is >316°C [ISO 3405].