Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- B08/0104A FLUIDE G3 FF
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- K7FX-E8HS-G00U-QW4D
Identified Uses
Transmission fluids
Manufacturers & Suppliers
TotalEnergies Lubrifiants
manufacturer
562 Avenue du Parc de L'ile 92029 Nanterre Cedex FRANCE
+33 (0)1 41 35 40 00
Emergency Contacts
France - ORFILA (INRS)
+33 (0)1 45 42 59 59
ANGERS
02 41 48 21 21
BORDEAUX
05 56 96 40 80
LILLE
08 00 59 59 59
LYON
04 72 11 69 11
MARSEILLE
04 91 75 25 25
NANCY
03 83 22 50 50
PARIS
01 40 05 48 48
TOULOUSE
05 61 77 74 47
Emergency Contact
+44 1235 239670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 50 - 75% | Yes |
| Distillates (petroleum), hydrotreated light naphthenic EC: 265-156-6 | 64742-53-6 | 3% | Yes |
| Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based EC: 276-738-4 | 72623-87-1 | 3% | Yes |
| Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 | 64742-56-9 | 3% | Yes |
| Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based EC: 276-737-9 | 72623-86-0 | 3% | Yes |
| Reaction product of: polyethylene-polyamine-(C16-C18)-alkylamides with monothio-(C2)-alkyl phosphonates EC: 417-450-2 | --- | 1% | Yes |
| methyl-1H-benzotriazole EC: 249-596-6 | 29385-43-1 | 0.3% | Yes |
| Phenol, dodecyl-, branched EC: 310-154-3 | 121158-58-5 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: irritation, redness, dryness, cracking
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes.
Wash out mouth with water. Remove dentures if any. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Immediate Medical Attention
Get medical attention if irritation occurs. Get medical attention if adverse health effects persist or are severe. If unconscious, get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Hydrocarbon-proof gloves, nitrile rubber, Fluorinated rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with ISO 21420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0,38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency
safety glasses with side-shields, EN 166.
Ensure adequate ventilation and check that a safe, breathable atmosphere is present before entry into confined spaces.. In case of inadequate ventilation wear respiratory protection: Type A/P1. Warning! filters have a limited use duration. The use of breathing apparatus must comply strictly with the manufacturer's instructions and the regulations governing their choices and uses..
Wear work clothing with long sleeves. Non-skid safety shoes or boots
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
No specific data.
Strong oxidizing agents
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
Results of PMT and vPvM assessment
12.5 Results of PBT and vPvB assessment
The product does not meet the criteria to be considered as a PBT or vPvB.
12.6 Endocrine disrupting properties
The product does not meet the criteria for endocrine disrupting properties.
12.7 Other adverse effects
No known significant effects or critical hazards.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Should not be released into the environment.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The information stated in this section relates solely to the conformity of the chemical product with the countries Inventories. Other regulations may apply for importation or marketing authorizations.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for B08/0104A FLUIDE G3 FF?
The signal word is warning.
What is the physical form of B08/0104A FLUIDE G3 FF?
B08/0104A FLUIDE G3 FF is a liquid. appearing as liquid. [limpid] with red. color. It has characteristic. odor.
What is B08/0104A FLUIDE G3 FF used for?
Transmission fluids
What are the hazard statements for B08/0104A FLUIDE G3 FF?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of B08/0104A FLUIDE G3 FF?
The melting point is Technically not possible to measure and the boiling point is >316°C [ISO 3405].