NextSDS Logo
Safety Data Sheet EN

PARASYN®DA6CP

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PARASYN®DA6CP
Product Code
n. a.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Base oil

Manufacturers & Suppliers

P

PURAGLOBE Germany GmbH

manufacturer

Hauptstraße 30, 06729 Elsteraue, Germany

+49(0)3441 / 22 815 0

Emergency Contacts

Emergency Contact

+49(0)361-730 730

Emergency Contact

+44 (0) 207 77 71 53 10

Emergency Contact

+32 (070) 24 52 45

Emergency Contact

+33 (1) 40 05 48 48

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways

Precautionary Statements

P331 Do NOT induce vomiting
P501 Dispose of contents/container to proper disposal
IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb

A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst

Chemical Name CAS Number Concentration Hazardous
A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst EC: 265-158-7 64742-55-8 --- No

The harmonized classification of this substance (H350) is no longer applicable because the concentration limits complied with according to the CLP regulation

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air

Skin contact

Remove contaminated clothing. Cleanse affected areas thoroughly by washing with soap and water. Clean contaminated clothing before re-use.

Eye contact

Flush eyes immediately with plenty of water

Ingestion

If swallowed, do not induce vomiting.

Immediate Medical Attention

Seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, dry powder, carbon dioxide, water spray jet, sand

Unsuitable media

Full water jet

Specific hazards

Formation of ignitable vapors / gases is possible. Hot product may produce flammable vapors.

Firefighter Protection

For fire fighters, use of breathing apparatus with independent air supply

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Take up with absorbent material smaller amounts of spilled material.

Environmental

Prevent spilled material from entering canalisation or aquatic environment. Dike spilled material using sand. Take up with absorbent material smaller amounts of spilled material.

Cleanup methods

If possible, skim off spill or absorb into an appropriate absorbent material. Dig out contaminated soil

Materials: absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not eat or drink while handling the product; avoid oil nebulisation, material spilling and local overheating. Keep away from sources of ignition. Hot product develops inflammable vapours.

Storage

Store this material in well-ventilated areas. Avoid direct exposure to heat and light. Do not store this material at high temperatures.

Hygiene

Do not eat or drink while handling the product

Fire prevention

Keep away from sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide for good ventilation

Hands

Gloves (oil-resistant)

Eyes

Safety goggles

Respiratory

No particular respiratory protection required in well-ventilated areas. Use respiratory protection for tank cleaning

Skin/Body

Long-sleeved protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
L 0.5
Colour Intensity
---
Form
liquid
Odor
–
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
≥ 300°C
Flash Point
Flashpoint – ASTM D 92 / DIN ISO 2592: ≥ 150 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
n.av.
Vapor Pressure
< 0.1 hPa
Vapor Density
n.av.
Relative Density
---
Bulk Density
---
Density
830 – 850 kg / m³
Flammability
---
Upper Explosive Limit
approx. 6.5 % with strong nebulisation
Lower Explosive Limit
approx. 0.6 % with strong nebulisation
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
n.av.
Partition Coefficient
n.av.
Solubility In Water
n.av.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
5-7 mm²/s (typical 6,0cSt)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Incompatible

Reaction with strong oxidising agents

Decomposition

None known hazardous decomposition products

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.2. Mobility

The product is not readily biodegradable.

The product is not readily biodegradable.

12.2. Mobility

The product is hardly soluble in water. It can be eliminated from the water by abiotic processes, e.g. mechanical separation.

The product is hardly soluble in water and can be eliminated from the water by abiotic processes, e.g. mechanical separation.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

The anticipated waste code No. is considered being a recommendation. If necessary, final assignment is to be made in coordination with the competent authority. The disposal information makes reference to this product and its residues resulting from the intended use. However, individual assessment is necessary if mixed with other materials or preparations.

Waste Codes

13 02 05* mineral-oil based non-chlorinated engine, gear and lubricating oil EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PARASYN®DA6CP?

The signal word is danger.

What is the physical form of PARASYN®DA6CP?

PARASYN®DA6CP is a liquid with l 0.5 color. It has – odor.

What is the solubility of PARASYN®DA6CP?

n.av.

What is PARASYN®DA6CP used for?

Base oil

What are the hazard statements for PARASYN®DA6CP?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways