Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Renoil 3501
- Synonyms
- Process Oil
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant, process oil Varied
Manufacturers & Suppliers
Renkert Oil
manufacturer
3817 Main Street, Morgantown, PA 19543
+1 (610) 286-8012
Emergency Contacts
CHEMTREC
(800) 424-9300
Emergency Contact
1 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated heavy paraffinic | 0064742-54-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air, keep patient warm and at rest. If breathing is irregular or stopped, give artificial respiration. If unconscious place in the recovery position and obtain immediate medical attention. Give nothing by mouth.
Symptoms: Inhalation of oil mists or vapors generated at elevated temperatures may cause respiratory irritation.
Remove contaminated clothing. Wash skin thoroughly with soap and water or use a recognized skin cleanser.
Immediately flush the eyes with large amounts of water for at least 15 minutes, alternately lifting the upper and lower eyelids. After 5 minutes, if appropriate, remove contact lenses and continue flushing the eyes for an additional 15 minutes. Call a physician at once.
If swallowed obtain immediate medical attention. Keep at rest. Do NOT induce vomiting.
Symptoms: Accidental ingestion can result in minor irritation of the digestive tract, nausea and diarrhea.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical attention. If unconscious place in the recovery position and obtain immediate medical attention. Call a physician at once. If swallowed obtain immediate medical attention.
Medical Treatment
Acute aspirations of large amounts of oil-laden material may produce a serious aspiration pneumonia. Patients who aspirate these oils should be followed for the development of long-term sequelae.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
alcohol resistant foam, CO₂, powder, water spray.
water jet.
Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.
Firefighter Protection
Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Put on appropriate personal protective equipment (see section 8).
Do not allow spills to enter drains or waterways.
Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W
---
Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W
---
Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T
---
Chevron Neutral Oil 150R
---
Chevron Neutral Oil 600R
---
Chevron Neutral Oil 600R
---
Chevron Neutral Oil 220R
---
Chevron Neutral Oil 220R
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from flames and hot surfaces. Use good personal hygiene practices and wear appropriate personal protective equipment. Spills will produce very slippery surfaces.
Use good personal hygiene practices
Keep away from flames and hot surfaces.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations of particulates and any vapor below occupational exposure limits suitable respiratory protection must be worn.
Nitrile rubber gloves should be worn.
No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.
If workers are exposed to concentrations above the exposure limit they must use the appropriate, certified respirators.
Wear overalls to keep skin contact to a minimum.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal circumstances.
Hazardous Polymerization will not occur.
No data available.
Extended exposure to high temperatures can cause decomposition. Avoid all possible sources of ignition.
Strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Not anticipated under conditions of normal use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Aquatic Ecotoxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment (persistent, bioaccumulative and toxic, very persistent, very bioaccumulative)
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.
Place contaminated materials in containers and dispose of in a manner consistent with applicable regulations. Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The regulatory data in Section 15 is not intended to be all-inclusive, only selected regulations are represented.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Renoil 3501 known by?
Renoil 3501 is also known as: Process Oil
What is the hazard signal word for Renoil 3501?
The signal word is no signal word.
What is the physical form of Renoil 3501?
Renoil 3501 is a colorless liquid appearing as colorless liquid with colorless color. It has petroleum odor odor.
What is Renoil 3501 used for?
Lubricant, process oil Varied
What is the melting point of Renoil 3501?
The melting point is Not Applicable and the boiling point is > 260 C (500 F).