Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T
- Synonyms
- White mineral oil
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant, personal care, food & plastics process oil
Manufacturers & Suppliers
Renkert Oil
manufacturer
3817 Main Street, Morgantown, PA 19543
+1 (610) 286-8012
Emergency Contacts
CHEMTREC
(800) 424-9300
CHEMTREC
1 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This product contains the following substances that present a hazard within the meaning of the relevant State and Federal Hazardous Substances regulations. This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| White mineral oil | 8042-47-5 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air, keep patient warm and at rest. If breathing is irregular or stopped, give artificial respiration. If unconscious place in the recovery position and obtain immediate medical attention. Give nothing by mouth.
Remove contaminated clothing. Wash skin thoroughly with soap and water or use a recognized skin cleanser.
Symptoms: Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the skin.
Immediately flush the eyes with large amounts of water for at least 15 minutes, alternately lifting the upper and lower eyelids. After 5 minutes, if appropriate, remove contact lenses and continue flushing the eyes for an additional 15 minutes.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do NOT induce vomiting.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
If unconscious place in the recovery position and obtain immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
alcohol resistant foam, CO₂, powder, water spray
water jet
Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.
Firefighter Protection
Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Put on appropriate personal protective equipment (see section 8).
Do not allow spills to enter drains or waterways.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Related Products
Similar products with comparable safety profiles
Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W
---
Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W
---
Renoil 3501
---
CHEVRON NEUTRAL OIL 100R, 220R, 600R
---
Chevron Neutral Oil 150R
---
CHEVRON NEUTRAL OIL 220R, 600R
---
Chevron Neutral Oil 220R
---
Chevron Neutral Oil 220R
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from flames and hot surfaces. Use good personal hygiene practices and wear appropriate personal protective equipment. Spills will produce very slippery surfaces.
Use good personal hygiene practices
Keep away from flames and hot surfaces.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations of particulates and any vapor below occupational exposure limits suitable respiratory protection must be worn.
Nitrile rubber gloves should be worn.
No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.
If workers are exposed to concentrations above the exposure limit they must use the appropriate, certified respirators.
Wear overalls to keep skin contact to a minimum.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal circumstances.
Hazardous Polymerization will not occur.
Extended exposure to high temperatures can cause decomposition. Avoid all possible sources of ignition.
Strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Not anticipated under conditions of normal use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2 Persistence and degradability
12.1 Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment (persistent, bioaccumulative and toxic, very persistent, very bioaccumulative) This product contains no PBT/vPvB chemicals.
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.
Place contaminated materials in containers and dispose of in a manner consistent with applicable regulations. Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- PETROLEUM OIL, N.O.I.B.N.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The regulatory data in Section 15 is not intended to be all-inclusive, only selected regulations are represented.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T known by?
Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T is also known as: White mineral oil
What is the hazard signal word for Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T?
The signal word is no signal word.
What is the physical form of Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T?
Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T is a colorless liquid appearing as colorless liquid with colorless color. It has petroleum odor odor.
What is the solubility of Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T?
Soluble in hydrocarbon solvents, insoluble in water.
What is Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T used for?
Lubricant, personal care, food & plastics process oil
What is the melting point of Renoil 130-T, Renoil 150-T, Renoil 180-T, Renoil 200-T, Renoil 220-T, Renoil 350-T, Renoil 380-T, Renoil 425-T, Renoil 500-T, Renoil 1000-T, Renoil 1350-T, Renoil 1500-T?
The melting point is Not Applicable and the boiling point is >260 C (500 F).