NextSDS Logo
Safety Data Sheet EN

Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W
Synonyms
White mineral oil

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119487078-27-0055

Identified Uses

Lubricant, personal care, food & plastics process oil

Manufacturers & Suppliers

Renkert Oil logo

Renkert Oil

manufacturer

3817 Main Street, Morgantown, PA 19543 USA

+1 610 286 8012

http://RenkertOil.com

R

Renkert Oil Europe BVBA

distributor

Blauwe Weg 44, Haven 227-243, 2030, Antwerp Belgium

+1 610 422 3567

Emergency Contacts

CHEMTREC (USA)

(800) 424-9300

CHEMTREC (USA)

1 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

See composition of ingredients in Section 3.2

Chemical Name CAS Number Concentration Hazardous
White mineral oil EC: 232-455-8 8042-47-5 100% No

Classification according to regulation (EC) No 1272/2008 (CLP) –

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air, keep patient warm and at rest. If breathing is irregular or stopped, give artificial respiration. If unconscious place in the recovery position and obtain immediate medical attention. Give nothing by mouth.

Skin contact

Remove contaminated clothing. Wash skin thoroughly with soap and water or use a recognized skin cleanser.

Symptoms: Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the skin.

Eye contact

Immediately flush the eyes with large amounts of water for at least 15 minutes, alternately lifting the upper and lower eyelids. After 5 minutes, if appropriate, remove contact lenses and continue flushing the eyes for an additional 15 minutes.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

Do NOT induce vomiting.

Symptoms: Not expected to be harmful if swallowed.

Immediate Medical Attention

If unconscious place in the recovery position and obtain immediate medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

alcohol resistant foam, CO₂, powder, water spray

Unsuitable media

water jet

Instructions

Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.

Firefighter Protection

Firefighting personnel should respond with appropriate protective clothing, firefighting gear, and breathing equipment as trained.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Put on appropriate personal protective equipment (see section 8).

Environmental

Do not allow spills to enter drains or waterways.

Cleanup methods

Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from flames and hot surfaces. Use good personal hygiene practices and wear appropriate personal protective equipment. Spills will produce very slippery surfaces.

Hygiene

Use good personal hygiene practices

Fire prevention

Keep away from flames and hot surfaces.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.

Hands

Nitrile rubber gloves should be worn.

Eyes

No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.

Respiratory

If workers are exposed to concentrations above the exposure limit they must use the appropriate, certified respirators.

Skin/Body

Wear overalls to keep skin contact to a minimum.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Colorless Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless Liquid
Colour
Colorless
Colour Intensity
---
Form
Liquid
Odor
Mild Petroleum Odor to Odorless
Odor Threshold
Not Measured
Ph
Not Applicable
Melting Point
Not Applicable
Boiling Point
>260 C (500 F)
Flash Point
350 F (177 C) minimum (Cleveland Open Cup)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not Measured
Vapor Pressure
< 0.01 mmHg @ 37.8 C (100 F)
Vapor Density
>1
Relative Density
0.85 - 0.88 @ 15.6 C (60.1F) / 15.6 C (60.1 F)
Bulk Density
---
Density
---
Flammability
Not Applicable
Upper Explosive Limit
Upper Explosive Limit: Not Measured
Lower Explosive Limit
Lower Explosive Limit: Not Measured
Explosive Limits
---
Auto Ignition Temperature
Not Measured
Decomposition Temperature
Not Measured
Solubility
Soluble in hydrocarbon solvents, insoluble in water.
Partition Coefficient
Not Measured
Solubility In Water
Soluble in hydrocarbon solvents, insoluble in water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
40-120 cSt @ 40 C (104 F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal circumstances.

Reactivity

Hazardous Polymerization will not occur.

Hazardous reactions

None known (none expected).

Avoid

Extended exposure to high temperatures can cause decomposition. Avoid all possible sources of ignition.

Incompatible

Strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Decomposition

Not anticipated under conditions of normal use.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

All acute aquatic toxicity studies on samples of similar oils show acute toxicity values greater than 100mg/l for invertebrates, algae and fish. These tests were carried out on water accommodated fractions and the results are consistent with predicted aquatic toxicity of these substances based on their hydrocarbon compositions. Not classified hazards.

Acute aquatic toxicity values are greater than 100 mg/L for invertebrates, algae, and fish.

12.2 Persistence and degradability

This material is considered inherently biodegradable. This material is not readily biodegradable.

The material is inherently biodegradable but not readily biodegradable.

Aquatic Ecotoxicity

Aquatic Ecotoxicity Ingredient | 96 hr LC50 fish, mg/l | 48 hr EC50 crustacea, mg/l | ErC50 algae, mg/l White Mineral Oil (8042-47-5) | 5,000, Oncorhynchus mykiss | 1,000, Daphnia magna | Not Available

12.2. Persistence and degradability

Persistence per IOPC Fund definition: persistent

12.3. Bioaccumulative potential

Not Measured

12.4. Mobility in soil

No data available.

12.5. Results of PBT and vPvB assessment (persistent, bioaccumulative and toxic, very persistent, very bioaccumulative) This product contains no PBT/vPvB chemicals.

This product contains no PBT/vPvB chemicals.

12.6. Other adverse effects

None expected
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.

Disposal

Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
PETROLEUM OIL, N.O.I.B.N., NOT REGULATED AS A HAZARDOUS MATERIAL
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The regulatory data in Section 15 is not intended to be all-inclusive, only selected regulations are represented.

Chemical Safety Assessment Not performed

This safety data sheet is in compliance with the following EU legislation and its adaptations - as far as applicable - : 67/548/EEC, 1999/45/EC, 98/24/EC, 92/85/EC, 94/33/EC, 91/689/EEC, 1999/13/EC, Commission Regulation (EU) 2015/830, Regulation (EC) No 1272/2008 and their amendments as well as the following British legislation: The Control of Substances Hazardous to Health Regulations (COSHH) 2002, COSHH Essentials, The Management of Health and Safety at Work Regulations 1999

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W known by?

Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W is also known as: White mineral oil

What is the hazard signal word for Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W?

The signal word is no signal word.

What is the physical form of Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W?

Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W is a colorless liquid appearing as colorless liquid with colorless color. It has mild petroleum odor to odorless odor.

What is the solubility of Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W?

Soluble in hydrocarbon solvents, insoluble in water.

What is Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W used for?

Lubricant, personal care, food & plastics process oil

What is the melting point of Renoil 220-W, Renoil 350-W, Renoil 380-W, Renoil 500-W?

The melting point is Not Applicable and the boiling point is >260 C (500 F).