Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Pure Performance® Base Oil 225N, 600N
- Product Code
- 817789
- Synonyms
- 230-HC, 600-HC
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119484627-25-0018
Identified Uses
Lubricant Base Oil
Uses advised against
Other uses are not recommended unless an assessment demonstrates potential exposures will be controlled.
Manufacturers & Suppliers
EXCEL PARALUBES LLC
manufacturer
2200 Old Spanish Trail Westlake, LA 70669
888-877-3170
Emergency Contacts
CHEMTREC Global
+1 703 527 3887
CHEMTREC UK
+(44)-870-8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates, petroleum, hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move victim away from source of exposure and into fresh air in a position comfortable for breathing.
Symptoms: Breathing difficulties.
Remove contaminated shoes and clothing and cleanse affected area(s) thoroughly by washing with mild soap and water or a waterless hand cleaner.
Symptoms: Irritation or redness.
Flush eyes with clean water.
Symptoms: Irritation or redness.
First aid is not normally required.
Symptoms: Accidental ingestion can result in minor irritation of the digestive tract, nausea and diarrhea.
Immediate Medical Attention
Seek immediate medical attention for inhalation. Seek medical attention if symptoms persist for eye contact, skin contact, or ingestion.
Medical Treatment
Acute aspirations of large amounts of oil-laden material may produce a serious aspiration pneumonia. Patients who aspirate these oils should be followed for the development of long-term sequelae.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical, carbon dioxide, foam, or water spray is recommended.
Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.
This material may burn, but will not ignite readily. If container is not properly cooled, it can rupture in the heat of a fire.
Isolate the hazard area and deny entry to unnecessary and unprotected personnel. Stop spill/release if it can be done safely. Move undamaged containers from immediate hazard area if it can be done safely. Water spray may be useful in minimizing or dispersing vapours and to protect personnel. Avoid spreading burning liquid with water used for cooling purposes. Cool equipment exposed to fire with water, if it can be done safely.
Firefighter Protection
For fires beyond the initial stage, emergency responders in the immediate hazard area should wear protective clothing. When the potential chemical hazard is unknown, in enclosed or confined spaces, a self contained breathing apparatus should be worn. In addition, wear other appropriate protective equipment as conditions warrant (see Section 8).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stay upwind and away from spill/release. Avoid direct contact with material. For large spillages, notify persons down wind of the spill/release, isolate immediate hazard area and keep unauthorised personnel out.
notify persons down wind of the spill/release, isolate immediate hazard area and keep unauthorised personnel out
Stop and contain spill/release if it can be done safely. Prevent spilled material from entering sewers, storm drains, other unauthorised drainage systems, and natural waterways. Use water sparingly to minimize environmental contamination and reduce disposal requirements.
Absorb spill with inert material such as sand or vermiculite, and place in suitable container for disposal.
Materials: sand or vermiculite
Related Products
Similar products with comparable safety profiles
Pure Performance® Base Oil 110N
---
PURITY™ 1810 BASE OIL
---
BASE OIL N-150, BASE OIL 150
CAS: 64742-54-7
PURITY™ L50 BASE OIL
CAS: 64742-55-8
aramcoULTRA 8 (Base Oil 250 Neutral)
CAS: 64742-54-7
aramcoULTRA 6 (Base Oil 150 Neutral)
CAS: 64742-54-7
aramcoULTRA 2 (Base Oil 60 Neutral)
CAS: 64742-55-8
aramcoULTRA 2 (Base Oil 60 Neutral)
CAS: 64742-55-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from flames and hot surfaces. Wash thoroughly after handling. Use good personal hygiene practices and wear appropriate personal protective equipment (see section 8). Spills will produce very slippery surfaces. Do not wear contaminated clothing or shoes. Do not enter confined spaces such as tanks or pits without following proper entry procedures.
Keep container(s) tightly closed and properly labeled. Use and store this material in cool, dry, well-ventilated area away from heat and all sources of ignition. Store only in approved containers. Keep away from any incompatible material. Protect container(s) against physical damage. Outdoor or detached storage is preferred. Indoor storage should meet Country or Committee standards and appropriate fire codes.
Wash thoroughly after handling. Use good personal hygiene practices. Do not wear contaminated clothing or shoes.
Keep away from flames and hot surfaces.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If current ventilation practices are not adequate to maintain airborne concentrations below the established exposure limits, additional engineering controls may be required.
The use of skin protection is not normally required; however, good industrial hygiene practise suggests the use of gloves or other appropriate skin protection meeting EN 374 whenever working with chemicals. Suggested protective materials: Nitrile rubber.
The use of eye/face protection is not normally required; however, good industrial hygiene practise suggests the use of eye protection that meets or exceeds EN 166 whenever working with chemicals.
Where there is potential for airborne exposure above the exposure limit an approved air purifying respirator equipped with Type P2 - Medium efficiency particle filters may be used. A respiratory protection programme that follows recommendations for the selection, use, care and maintenance of respiratory protective devices in EN 529:2005 should be followed whenever workplace conditions warrant a respirator's use. Air purifying respirators provide limited protection and cannot be used in atmospheres that exceed the maximum use concentration (as directed by regulation or the manufacturer's instructions), in oxygen deficient (less than 19.5 percent oxygen) situations, or under conditions that are immediately dangerous to life and health.
The use of skin protection is not normally required; however, good industrial hygiene practise suggests the use of gloves or other appropriate skin protection meeting EN 374 whenever working with chemicals.
Refer to Sections 6, 7, 12 and 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal ambient and anticipated conditions of use.
Not chemically reactive.
Hazardous reactions not anticipated.
Extended exposure to high temperatures can cause decomposition. Avoid all possible sources of ignition.
Avoid contact with strong oxidizing agents and strong reducing agents.
Not anticipated under normal conditions of use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The substance is not considered to be a PBT or vPvB substance.
12.6 Endocrine disrupting properties
The currently available information does not indicate that this substance has endocrine disrupting properties as defined by the criteria set out in Section B of Regulation (EU) No 2017/2100.
12.7 Other adverse effects
None anticipated.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Whenever possible, Directive 75/439/EEC suggests recycling of 'waste oils' in accordance with current national and regional provisions.
This material, if discarded as produced, would be considered as hazardous waste pursuant to Directive 2008/98/EC on hazardous waste, and subject to the provisions of that Directive unless Article 1(5) of that Directive applies.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
If transported in bulk by marine vessel in international waters, product is being carried under the scope of MARPOL Annex I.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture
Export Rating: NLR (No Licence Required). Standards mentioned: EN166:2002 (Eye Protection), EN 529:2005 (Respiratory Protective devices), BS EN 374-1:2016 (Protective gloves).
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Pure Performance® Base Oil 225N, 600N known by?
Pure Performance® Base Oil 225N, 600N is also known as: 230-HC, 600-HC
What is the hazard signal word for Pure Performance® Base Oil 225N, 600N?
The signal word is no signal word.
What is the physical form of Pure Performance® Base Oil 225N, 600N?
Pure Performance® Base Oil 225N, 600N is a liquid with clear and bright; water-white color. It has petroleum odor.
What is the solubility of Pure Performance® Base Oil 225N, 600N?
Insoluble
What is Pure Performance® Base Oil 225N, 600N used for?
Lubricant Base Oil
What is the melting point of Pure Performance® Base Oil 225N, 600N?
The melting point is N/D and the boiling point is N/D.