NextSDS Logo
Safety Data Sheet EN

Chemart-990

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Chemart-990

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Grinding aid for cement

Uses advised against

Anything other than the above.

Manufacturers & Suppliers

C

Chemartis SA

manufacturer

P.O. Box 186 1028 Préverenges, Switzerland

+41 21 803 07 39

Emergency Contacts

Emergency Contact

+41 21 803 07 39

CET (+1 UTC)

EN, FR, DE

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Diethylene glycol EC: 203-872-2 111-46-6 15% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

IF INHALED: If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

IF ON SKIN: Wash with plenty of water. If skin irritation occurs: Get medical advice/attention.

Eye contact

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation develops and persists, get medical attention.

Ingestion

Rinse mouth. Get medical advice/attention if you feel unwell.

Immediate Medical Attention

If skin irritation occurs: Get medical advice/attention. If irritation develops and persists, get medical attention. Get medical advice/attention if you feel unwell.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

As appropriate for surrounding fire.

Unsuitable media

Direct water jet may spread the fire.

Specific hazards

Product is not classified as flammable, but will burn on contact with flame or exposure to high temperature. Combustion may cause toxic fumes.

Instructions

Fight fire with normal precautions from a reasonable distance. Keep containers cool by spraying with water if exposed to fire.

Firefighter Protection

Fire fighters should wear complete protective clothing including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Caution - spillages may be slippery. Eliminate sources of ignition. Shut off leaks if without risk. Avoid contact with skin and eyes. Ensure adequate ventilation. Avoid breathing vapours.

Environmental

Avoid release to the environment.

Cleanup methods

Transfer to a container for disposal. Wash the spillage area with water.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure adequate ventilation. Avoid inhalation of high concentrations of vapours. Use personal protective equipment as required. Avoid contact with skin, eyes or clothing.

Storage

Store in a cool/low-temperature, well-ventilated (dry) place away from heat and ignition sources. Store in a cool dry place away from sources of heat and UV light.

Hygiene

Do not eat, drink or smoke when using this product. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation. Store in a cool/low-temperature, well-ventilated (dry) place away from heat and ignition sources.

Hands

Wear suitable chemical resistant protective gloves for frequent or prolonged operations tested to EN374 with an acceptable permeation test. Contaminated gloves should be carefully rinsed with water before reuse.

Eyes

Use eye protection according to EN 166, designed to protect against liquid splashes.

Respiratory

Respiratory protection is not necessary if room is well ventilated. In case of inadequate ventilation wear respiratory protection.

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Yellowish Liquid
Colour
Yellowish
Colour Intensity
---
Form
Liquid
Odor
Weak
Odor Threshold
Not established
Ph
7.5 – 10.0 @ 20°C
Melting Point
103°C
Boiling Point
-15°C
Flash Point
Not established
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not established
Vapor Pressure
Not established
Vapor Density
Not established
Relative Density
1.15 – 1.20g/ml @ 20°C
Bulk Density
---
Density
---
Flammability
Not relevant - liquid mixture
Upper Explosive Limit
Not established
Lower Explosive Limit
Not established
Explosive Limits
---
Auto Ignition Temperature
Not established
Decomposition Temperature
Not established
Solubility
Soluble in water.
Partition Coefficient
Not established
Solubility In Water
Soluble in water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
15-20 mPas @ 20°C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

Stable under normal conditions.

Avoid

None anticipated. Product is not classified as flammable, but will burn on contact with flame or exposure to high temperature.

Incompatible

Strong oxidising agents, Strong acids and alkali. Nitric acid

Decomposition

Combustion may cause toxic fumes. (Carbon monoxide, Carbon dioxide).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

No ecotoxic effects are known for this product.

12.2 Persistence and degradability

No data for the mixture as a whole.

12.2 Persistence and degradability

Diethylene glycol: Readily biodegradable (according to OECD criteria).

12.3 Bioaccumulative potential

No data for the mixture as a whole.

No data for the mixture as a whole.

12.3 Bioaccumulative potential

Diethylene glycol: The substance has low potential for bioaccumulation.

The substance has low potential for bioaccumulation.

12.4 Mobility in soil

The product is predicted to have high mobility in soil. Soluble in water. Diethylene glycol: The substance is predicted to have high mobility in soil.

12.5 Results of PBT and VPVB assessment

Not classified as PBT or vPvB.

The substance is not classified as PBT or vPvB.

12.6 Other adverse effects

None known.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal should be in accordance with local, state or national legislation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

ACCORDING TO EC-REGULATIONS 1907/2006 (REACH), 1272/2008 (CLP) & 2015/830

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Chemart-990?

The signal word is no signal word.

What is the physical form of Chemart-990?

Chemart-990 is a liquid appearing as yellowish liquid with yellowish color. It has weak odor.

What is the solubility of Chemart-990?

Soluble in water.

What is Chemart-990 used for?

Grinding aid for cement

What is the melting point of Chemart-990?

The melting point is 103°C and the boiling point is -15°C.