Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Chemart-990
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Grinding aid for cement
Uses advised against
Anything other than the above.
Manufacturers & Suppliers
Chemartis SA
manufacturer
P.O. Box 186 1028 Préverenges, Switzerland
+41 21 803 07 39
Emergency Contacts
Emergency Contact
+41 21 803 07 39
CET (+1 UTC)
EN, FR, DE
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diethylene glycol EC: 203-872-2 | 111-46-6 | 15% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
IF INHALED: If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing.
IF ON SKIN: Wash with plenty of water. If skin irritation occurs: Get medical advice/attention.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation develops and persists, get medical attention.
Rinse mouth. Get medical advice/attention if you feel unwell.
Immediate Medical Attention
If skin irritation occurs: Get medical advice/attention. If irritation develops and persists, get medical attention. Get medical advice/attention if you feel unwell.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
As appropriate for surrounding fire.
Direct water jet may spread the fire.
Product is not classified as flammable, but will burn on contact with flame or exposure to high temperature. Combustion may cause toxic fumes.
Fight fire with normal precautions from a reasonable distance. Keep containers cool by spraying with water if exposed to fire.
Firefighter Protection
Fire fighters should wear complete protective clothing including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Caution - spillages may be slippery. Eliminate sources of ignition. Shut off leaks if without risk. Avoid contact with skin and eyes. Ensure adequate ventilation. Avoid breathing vapours.
Avoid release to the environment.
Transfer to a container for disposal. Wash the spillage area with water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure adequate ventilation. Avoid inhalation of high concentrations of vapours. Use personal protective equipment as required. Avoid contact with skin, eyes or clothing.
Store in a cool/low-temperature, well-ventilated (dry) place away from heat and ignition sources. Store in a cool dry place away from sources of heat and UV light.
Do not eat, drink or smoke when using this product. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation. Store in a cool/low-temperature, well-ventilated (dry) place away from heat and ignition sources.
Wear suitable chemical resistant protective gloves for frequent or prolonged operations tested to EN374 with an acceptable permeation test. Contaminated gloves should be carefully rinsed with water before reuse.
Use eye protection according to EN 166, designed to protect against liquid splashes.
Respiratory protection is not necessary if room is well ventilated. In case of inadequate ventilation wear respiratory protection.
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable under normal conditions.
Stable under normal conditions.
None anticipated. Product is not classified as flammable, but will burn on contact with flame or exposure to high temperature.
Strong oxidising agents, Strong acids and alkali. Nitric acid
Combustion may cause toxic fumes. (Carbon monoxide, Carbon dioxide).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
No data for the mixture as a whole.
12.3 Bioaccumulative potential
The substance has low potential for bioaccumulation.
12.4 Mobility in soil
12.5 Results of PBT and VPVB assessment
The substance is not classified as PBT or vPvB.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal should be in accordance with local, state or national legislation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
ACCORDING TO EC-REGULATIONS 1907/2006 (REACH), 1272/2008 (CLP) & 2015/830
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Chemart-990?
The signal word is no signal word.
What is the physical form of Chemart-990?
Chemart-990 is a liquid appearing as yellowish liquid with yellowish color. It has weak odor.
What is the solubility of Chemart-990?
Soluble in water.
What is Chemart-990 used for?
Grinding aid for cement
What is the melting point of Chemart-990?
The melting point is 103°C and the boiling point is -15°C.