NextSDS Logo
Safety Data Sheet EN

D94099 CHROMATINT LILAC 2799

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
D94099 CHROMATINT LILAC 2799
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Dyestuff, product for industrial use only. Industrial

Uses advised against

No additional information available

Manufacturers & Suppliers

C

CHROMATECH EUROPE B.V.

manufacturer

Dijkweg 159 2675 AD Honselersdijk The Netherlands

+31(0)174272299

Emergency Contacts

Emergency Contact

+31(0)174272299

This number is serviced during office hours.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH Annex II

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take victim to fresh air, in a quiet place and if necessary take medical advice. If unconscious, place in the recovery position and seek medical advice.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Do not remove clothing if it sticks to the skin.

Eye contact

Rinse immediately with plenty of water, also under the eyelids. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth out with water.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing media appropriate for surrounding fire. e.g. Water spray. Dry powder. Carbon dioxide (CO2). Alcohol resistant foam.

Unsuitable media

Strong water jet.

Specific hazards

Fire hazard : No fire hazard (Aqueous solution). Explosion hazard : Product is not explosive.

Instructions

Exercise caution when fighting any chemical fire. Cool tanks/drums with water spray/remove them into safety.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Provide adequate ventilation. Wear suitable respiratory equipment in case of insufficient ventilation. Keep unprotected persons from entering.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Clean up any spills as soon as possible, using an absorbent material to collect it. Wash away remainder with plenty of water.

Materials: absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid all unnecessary exposure.

Storage

Keep container closed when not in use.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Do not drink, eat or smoke in the workplace.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ventilate area. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure.

Hands

Recommended: Chemical resistant gloves (according to European standard NF EN 374 or equivalent), Since the product consists of several substances, it is not possible to estimate the durability of the glove material beforehand and it therefore needs to be tested before use

Eyes

Recommended: Chemical goggles or safety glasses

Respiratory

No personal breathing protective equipment is normally required

Skin/Body

Wear suitable protective clothing

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid.
Colour
red-violet.
Colour Intensity
---
Form
---
Odor
slight.
Odor Threshold
No data available
Ph
No data available
Melting Point
≈ 0 °C
Boiling Point
≈ 100 °C
Flash Point
No data available
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
---
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1.1 – 1.2 g/cm³
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
Not self-igniting
Decomposition Temperature
No data available
Solubility
Water: Miscible
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of use.

Reactivity

No additional information available

Hazardous reactions

No dangerous reactions known.

Avoid

High temperature.

Incompatible

Oxidizing and reducing agents may destroy the dye.

Decomposition

When exposed to high temperatures may produce hazardous decomposition products such as carbon monoxide and dioxide, smoke, nitrogen oxides (NOx).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Ecology - general : Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system. Hazardous to the aquatic environment, short-term (acute) : Not classified Hazardous to the aquatic environment, long-term (chronic) : Not classified Not rapidly degradable

The product is not classified as hazardous to the aquatic environment (acute or chronic).

12.2. Persistence and degradability

12.2. Persistence and degradability

Colourants by their nature are stable and not readily biodegradable.

Colourants by their nature are stable and not readily biodegradable.

12.3. Bioaccumulative potential

No additional information available

12.4. Mobility in soil

No additional information available

12.5. Results of PBT and vPvB assessment

| D94099 CHROMATINT LILAC 2799 | | | --- | --- | | Results of PBT assessment | No data available |

12.6. Other adverse effects

No additional information available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Remove to an authorized waste treatment plant.

Disposal

If recycling is not possible, eliminate in accordance with local valid waste disposal regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for D94099 CHROMATINT LILAC 2799?

The signal word is no signal word.

What is the physical form of D94099 CHROMATINT LILAC 2799?

D94099 CHROMATINT LILAC 2799 is a liquid appearing as liquid. with red-violet. color. It has slight. odor.

What is the solubility of D94099 CHROMATINT LILAC 2799?

Water: Miscible

What is D94099 CHROMATINT LILAC 2799 used for?

Dyestuff, product for industrial use only. Industrial

What is the melting point of D94099 CHROMATINT LILAC 2799?

The melting point is ≈ 0 °C and the boiling point is ≈ 100 °C.