Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SP PRIOLUBE 3970 MBAL-LQ-(GD)
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119498305-31-0001
Identified Uses
Hydraulic fluids, Lubricants, greases, release products, Metal working fluids, Fillers, putties, plasters, modelling clay, Fuels, Ink and toners, Polishes and wax blends
Manufacturers & Suppliers
Croda GmbH
manufacturer
Herrenpfad-Sud 33 41334 Nettetal DE
+49215781730
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
GFL
1-877-898-7222
Emergency Contact
00 32 3575 5555
Emergency Contact
+65 6542-9595
Emergency Contact
+86 816-635 2206
Emergency Contact
+61 2 7808 3390
Emergency Contact
+32 3 575 55 55
Ambipar
0800 117 2020
Suatrans
(+55) 11 98149-0850
Suatrans
(+55) 19 3833-5300
Emergency Contact
+91 22 30948601/2
Emergency Contact
+65 6542 9595
Sağlik Bakanlığı Ulusal Zehir Merkezi
114
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No hazardous ingredients
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If symptoms persist, call a physician.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.
Immediately flush eye(s) with plenty of water. If eye irritation persists, consult a specialist.
If symptoms persist, call a physician.
Medical Treatment
None known.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
High volume water jet
Standard procedure for chemical fires.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Prevent product from entering drains.
Soak up with inert absorbent material. Sweep up and shovel into suitable containers for disposal.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice.
Store in original container. Keep container tightly closed in a dry and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Remarks: For prolonged or repeated contact use protective gloves.
Safety glasses
No personal respiratory protective equipment normally required.
Impervious clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No data available
No data available
Stable under recommended storage conditions.
None known.
Strong oxidizing agents
No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of product residue in accordance with the instructions of the person responsible for waste disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
15.2 Chemical safety assessment not hazardous
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SP PRIOLUBE 3970 MBAL-LQ-(GD)?
The signal word is no signal word.
What is the physical form of SP PRIOLUBE 3970 MBAL-LQ-(GD)?
SP PRIOLUBE 3970 MBAL-LQ-(GD) is a liquid appearing as clear, liquid with light yellow color. It has no data available odor.
What is SP PRIOLUBE 3970 MBAL-LQ-(GD) used for?
Hydraulic fluids, Lubricants, greases, release products, Metal working fluids, Fillers, putties, plasters, modelling clay, Fuels, Ink and toners, Polishes and wax blends