Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PXL 7811
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 1M90-F0X1-000V-STNN
Identified Uses
Oils
Uses advised against
All uses not specified in this section or in section 7.3
Manufacturers & Suppliers
PXL Chemicals B.V.
manufacturer
Pesetastraat 68, 2991 XT Barendrecht - Zuid Holland - The Netherlands
+31102123322
http://www.pxlchemicals.com
Emergency Contacts
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Benzenamine, N-phenyl-, reaction products with 2,4,4-trimethylpentene EC: 270-128-1 | 68411-46-1 | 5 - 10% | Yes |
| 4,4'-methylene bis(dibutyldithiocarbamate) EC: 233-593-1 | 10254-57-6 | 3 - 5% | Yes |
| Dibutyl [(bis[(2-ethylhexyl)oxy]phosphinothioyl]thio]succinate EC: 270-220-1 | 68413-48-9 | 3 - 5% | Yes |
| 1,3,4-Thiadiazolidine-2,5-dithione, reaction products with hydrogen peroxide and tert-nonanethiol EC: 293-927-7 | 91648-65-6 | 1 - 3% | Yes |
| reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 | 125643-61-0 | 1 - 3% | Yes |
| Phenol, isopropylated, phosphate (3:1) [Triphenyl phosphate < 5%] EC: 273-066-3 | 68937-41-7 | 1 - 3% | Yes |
| Benzenesulfonic acid, C10-16-alkyl derivs., calcium salts EC: 271-529-4 | 68584-23-6 | 1 - 3% | Yes |
| Sulfonic acids, petroleum, calcium salts (TBN < 300) EC: 263-093-9 | 61789-86-4 | 0.5 - 1% | Yes |
| Benzenesulfonic acid, mono-C16-24-alkyl derivs., calcium salts EC: 274-263-7 | 70024-69-0 | 40.1% | Yes |
| Dibutyl fumarate EC: 203-327-9 | 105-75-9 | 40.1% | Yes |
| Ethyl acrylate EC: 205-438-8 | 140-88-5 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the person affected from the area of exposure, provide clean air and keep at rest. Request medical attention if symptoms persist.
Clean the affected area thoroughly with water and neutral soap.
Symptoms: May cause an allergic skin reaction. Changes on the skin (stinging, redness, rashes, blisters).
Rinse eyes thoroughly with water for at least 15 minutes. If the injured person uses contact lenses, these should be removed unless they are stuck to the eyes, in which case removal could cause further damage. In all cases, after cleaning, a doctor should be consulted as quickly as possible with the SDS for the product.
Do not induce vomiting, but if it does happen keep the head down to avoid aspiration. Keep the person affected at rest. Rinse out the mouth and throat, as they may have been affected during ingestion.
Immediate Medical Attention
In case of doubt, seek medical attention for direct exposure to the chemical product or persistent discomfort, showing the SDS of this product. In case of changes on the skin (stinging, redness, rashes, blisters), seek medical advice with this Safety Data Sheet. In all cases [of eye contact], after cleaning, a doctor should be consulted as quickly as possible with the SDS for the product.
Medical Treatment
Not relevant
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
If possible use polyvalent powder fire extinguishers (ABC powder), alternatively use foam or carbon dioxide extinguishers $(\mathrm{CO}_{2})$.
IT IS RECOMMENDED NOT to use full jet water as an extinguishing agent.
As a result of combustion or thermal decomposition reactive sub-products are created that can become highly toxic and, consequently, can present a serious health risk.
Act in accordance with the Internal Emergency Plan and the Information Sheets on actions to take after an accident or other emergencies. Eliminate all sources of ignition. In case of fire, cool the storage containers and tanks for products susceptible to combustion, explosion or BLEVE as a result of high temperatures.
Firefighter Protection
Depending on the magnitude of the fire it may be necessary to use full protective clothing and Self Contained Breathing Apparatus. Minimum emergency facilities and equipment should be available (fire blankets, portable first aid kit,...)
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate leaks provided that there is no additional risk for the people performing this task. Evacuate the area and keep out those without protection.
Contain spillage using barriers or similar equipment. Use suitable absorbents for collection and treat the waste in accordance with current regulations.
If possible, contain spillage in open water using barriers or similar equipment. If this is not possible, try to control its spread and collect the product with suitable mechanical means. Always consult experts before using dispersants and make sure you have the necessary approvals if they are to be used. Treat the waste according to current regulations.
Avoid at all cost any type of spillage into an aqueous medium.
Absorb the spill using sand or inert absorbent and move it to a safe place. Collect the product in appropriate containers.
Materials: sand or inert absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Comply with the current legislation concerning the prevention of industrial risks with regards manually handling weights. Maintain order, cleanliness and dispose of using safe methods. PREGNANT WOMEN SHOULD NOT BE EXPOSED TO THIS PRODUCT. Transfer in designated areas that comply with the necessary safety conditions (emergency showers and eyewash stations in close proximity), using personal protection equipment, especially on the hands and face. Limit manual transfers to small amounts only. Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.
Avoid sources of heat, radiation, static electricity and contact with food.
Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.
Avoid the evaporation of the product as it contains flammable substances, which could form flammable vapour/air mixtures in the presence of sources of ignition. Control sources of ignition (mobile phones, sparks,...) and transfer at slow speeds to avoid the creation of electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
NON-disposable chemical protective gloves (Material: Nitrile, Breakthrough time: >240 min, Thickness: 0.4 mm), CE CAT III, EN ISO 374-1:2016+A1:2018 EN 16523-1:2015+A1:2018 EN ISO 21420:2020. The Breakthrough Time indicated by the manufacturer must exceed the period during which the product is being used. Do not use protective creams after the product has come into contact with skin.
Face shield, CE CAT II, EN 166:2002 UNE-EN ISO 18526-1 al 4:2020 UNE-EN ISO 18526-1 al 4:2020 EN ISO 4007:2018. Clean daily and disinfect periodically according to the manufacturer's instructions. Use if there is a risk of splashing.
Filter mask for gases and vapours (Filter type: A), CE CAT III, EN 405:2002+A1:2010. Replace when there is a taste or smell of the contaminant inside the face mask. If the contaminant comes with warnings it is recommended to use isolation equipment.
Disposable clothing for protection against chemical risks, CE CAT III, EN 13034:2005+A1:2009 UNE-EN ISO 18526-1 al 4:2020 EN ISO 13982-1:2005/A1:2011 EN ISO 6529:2013 EN ISO 6530:2005 EN 464:1995. Safety footwear for protection against chemical risk, CE CAT III, EN ISO 20345:2022 EN 13832-1:2019.
To comply with environmental protection regulations, it is recommended to prevent any spillage of the product and its container.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable under the indicated conditions of storage, handling and use.
No hazardous reactions are expected because the product is stable under recommended storage conditions.
Under the specified conditions, hazardous reactions that lead to excessive temperatures or pressure are not expected.
Shock and friction: Not applicable, Contact with air: Not applicable, Increase in temperature: Precaution, Sunlight: Precaution, Humidity: Not applicable.
Strong acids, oxidising materials, alkalis or strong bases
See sub section 10.3, 10.4 and 10.5 to find out the specific decomposition products. Depending on the decomposition conditions, complex mixtures of chemical substances can be released: carbon dioxide (CO₂), carbon monoxide and other organic compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential:
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
The product does not meet the criteria for endocrine-disrupting properties.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Consult the authorized waste service manager on the assessment and disposal operations in accordance with Annex 1 and Annex 2 (Directive 2008/98/EC).
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
It is recommended to use the information included in this safety data sheet as a basis for conducting workplace-specific risk assessments in order to establish the necessary risk prevention measures for the handling, use, storage and disposal of this product.
The product could be affected by sectorial legislation
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PXL 7811?
The signal word is warning.
What is the physical form of PXL 7811?
PXL 7811 is a liquid appearing as viscous with brown color. It has characteristic odor.
What is the solubility of PXL 7811?
Not relevant *
What is PXL 7811 used for?
Oils
What are the hazard statements for PXL 7811?
This substance has 3 hazard statements:
- H317: May cause an allergic skin reaction.
- H361f: Suspected of damaging fertility.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of PXL 7811?
The melting point is <-40 °C (ASTM D 97) and the boiling point is >350 °C.