Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PXL 5988

Regulatory Identifiers

CAS Number
N/A
UFI Code
DP20-G00V-600T-65FE

Identified Uses

Oils

Uses advised against

All uses not specified in this section or in section 7.3

Manufacturers & Suppliers

PXL Chemicals B.V. logo

PXL Chemicals B.V.

manufacturer

Pesetastraat 68, 2991 XT Barendrecht - Zuid Holland - The Netherlands

+31102123322

http://www.pxlchemicals.com

Emergency Contacts

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/container in accordance with regulations on hazardous waste or packaging and packaging waste respectively.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 --- 3 - 5% Yes
Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr) esters, zinc salts EC: 283-392-8 84605-29-8 3 - 5% Yes
Benzenamine, N-phenyl-, reaction products with 2,4,4-trimethylpentene EC: 270-128-1 68411-46-1 1 - 3% Yes
reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 125643-61-0 1 - 3% Yes
Benzenesulfonic acid, C10-16-alkyl derivs., calcium salts EC: 271-529-4 68584-23-6 0.5 - 1% Yes
Sulfonic acids, petroleum, calcium salts (TBN < 300) EC: 263-093-9 61789-86-4 0.5 - 1% Yes
Benzenesulfonic acid, mono-C16-24-alkyl derivs., calcium salts EC: 274-263-7 70024-69-0 0.1 - 0.3% Yes
Phenol, dodecyl-, branched EC: 310-154-3 121158-58-5 0.1 - 0.3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the person affected from the exposure area and provide with fresh air. Seek medical attention if the symptoms get worse or persist.

Skin contact

Remove contaminated clothes and shoes, rinse the skin or if necessary shower the affected person thoroughly with cold water and neutral soap. In case of serious reaction consult a doctor.

Eye contact

Rinse eyes thoroughly with water for at least 15 minutes. If the injured person uses contact lenses, these should be removed unless they are stuck to the eyes, in which case removal could cause further damage. In all cases, after cleaning, a doctor should be consulted as quickly as possible with the SDS for the product.

Ingestion

Do not induce vomiting, but if it does happen keep the head down to avoid aspiration. Keep the person affected at rest. Rinse out the mouth and throat, as they may have been affected during ingestion.

Immediate Medical Attention

Seek medical attention if the symptoms get worse or persist (inhalation). In case of serious reaction consult a doctor (skin). In all cases, after cleaning, a doctor should be consulted as quickly as possible with the SDS for the product (eye).

Medical Treatment

Not relevant

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

If possible use polyvalent powder fire extinguishers (ABC powder), alternatively use foam or carbon dioxide extinguishers (CO₂).

Unsuitable media

IT IS RECOMMENDED NOT to use full jet water as an extinguishing agent.

Specific hazards

As a result of combustion or thermal decomposition reactive sub-products are created that can become highly toxic and, consequently, can present a serious health risk.

Instructions

Act in accordance with the Internal Emergency Plan and the Information Sheets on actions to take after an accident or other emergencies. Eliminate all sources of ignition.

Firefighter Protection

Depending on the magnitude of the fire it may be necessary to use full protective clothing and Self Contained Breathing Apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate leaks provided that there is no additional risk for the people performing this task. Evacuate the area and keep out those who do not have protection.

Small spill

Contain spillage using barriers or similar equipment. Use suitable absorbents for collection and treat the waste in accordance with current regulations.

Large spill

If possible, contain spillage in open water using barriers or similar equipment. If this is not possible, try to control its spread and collect the product with suitable mechanical means. Always consult experts before using dispersants and make sure you have the necessary approvals if they are to be used. Treat the waste according to current regulations.

Environmental

Avoid at all cost any type of spillage into an aqueous medium.

Cleanup methods

Contain the product absorbed appropriately in hermetically sealed containers.

Materials: sand or inert absorbent

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Comply with the current legislation concerning the prevention of industrial risks with regards manually handling weights. Maintain order, cleanliness and dispose of using safe methods (section 6).

Storage

Avoid sources of heat, radiation, static electricity and contact with food.

Hygiene

Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.

Fire prevention

Product is non-flammable under normal conditions of storage, handling and use. It is recommended to transfer at slow speeds to avoid the generation of electrostatic charges that can affect flammable products.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical protective gloves (Material: Nitrile, Breakthrough time: > 60 min, Thickness: 0.1 mm), EN ISO 21420:2020. Replace the gloves at any sign of deterioration.

Eyes

Panoramic glasses against splash/projections. EN 166:2002, EN ISO 4007:2018. Clean daily and disinfect periodically according to the manufacturer´s instructions. Use if there is a risk of splashing.

Respiratory

If the working conditions and/or safety measures adopted do not allow keeping the airborne concentration of the product below the exposure limits (if any) or at acceptable levels (if no exposure limits exist), suitable respiratory protection equipment chosen by a qualified professional should be used.

Skin/Body

Work clothing. For periods of prolonged exposure to the product for professional/industrial users CE III is recommended, in accordance with the regulations in EN ISO 6529:2013, EN ISO 6530:2005, EN ISO 13688:2013, EN 464:1994. Replace before any evidence of deterioration. Anti-slip work shoes, EN ISO 20347:2022. For periods of prolonged exposure to the product for professional/industrial users CE III is recommended, in accordance with the regulations in EN ISO 20345:2022 y EN 13832-1:2019. Replace before any evidence of deterioration.

Environmental

To comply with environmental protection regulations, it is recommended to prevent any spillage of the product and its container.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Viscous
Colour
Brown
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not relevant *
Ph
Not relevant *
Melting Point
-13 ºC
Boiling Point
>350 ºC
Flash Point
>180 ºC (ASTM D-92)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not relevant *
Vapor Pressure
>5,051E-7 Pa (at 20 ºC); <0,1 Pa (<0 kPa) (at 50 ºC)
Vapor Density
---
Relative Density
~0,95
Bulk Density
---
Density
≈950 kg/m³ (ASTM-D-1505)
Flammability
Not relevant *
Upper Explosive Limit
Not relevant *
Lower Explosive Limit
Not relevant *
Explosive Limits
---
Auto Ignition Temperature
>260 ºC
Decomposition Temperature
>120 ºC
Solubility
Not relevant *
Partition Coefficient
Not relevant *
Solubility In Water
Not relevant *
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
Not relevant *
Dynamic Viscosity
Not relevant *
Kinematic Viscosity
~3200 mm²/s (at 40 ºC); ~190 mm²/s (at 100 ºC)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Chemically stable under the indicated conditions of storage, handling and use.

Reactivity

No hazardous reactions are expected because the product is stable under recommended storage conditions.

Hazardous reactions

Under the specified conditions, hazardous reactions that lead to excessive temperatures or pressure are not expected.

Avoid

Shock and friction: Not applicable; Contact with air: Not applicable; Increase in temperature: Not applicable; Sunlight: Not applicable; Humidity: Not applicable

Incompatible

Acids: Avoid strong acids; Oxidising materials: Precaution; Others: Avoid alkalis or strong bases

Decomposition

See sub section 10.3, 10.4 and 10.5 to find out the specific decomposition products. Depending on the decomposition conditions, complex mixtures of chemical substances can be released: carbon dioxide (CO₂), carbon monoxide and other organic compounds.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Acute toxicity: |Identification||Concentration|Species|Genus| |---|---|---|---|---|

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

|Identification||Concentration|Species|Genus| |Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr) esters, zinc salts|LC50|>1 - 10 mg/L (96 h)||Fish| |CAS: 84605-29-8|EC50|>1 - 10 mg/L (48 h)||Crustacean| |EC: 283-392-8|EC50|>1 - 10 mg/L (72 h)||Algae|

12.1 Toxicity

Identification || Concentration | Species | Genus Benzenesulfonic acid, C10-16-alkyl derivs., calcium salts | LC50 | >10000 mg/L (96 h) | N/A | Fish CAS: 68584-23-6 | EC50 | >1000 mg/L (48 h) | Daphnia magna | Crustacean EC: 271-529-4 | EC50 | >1000 mg/L (72 h) | Pseudokirchneriella subcapitata | Algae

12.1 Toxicity

Identification | Concentration | Species | Genus | Phenol, dodecyl-, branched | LC50 | Not relevant | | | CAS: 121158-58-5 | EC50 | 0,11 mg/L (48 h) | Daphnia magna | Crustacean | EC: 310-154-3 Chronic toxicity: | EC50 | Not relevant | | |

12.1 Toxicity

12.1 Toxicity: |Identification||Concentration|Species|Genus| |Phenol, dodecyl-, branched|NOEC|Not relevant||| |CAS: 121158-58-5 EC: 310-154-3|NOEC|0,004 mg/L|Daphnia magna|Crustacean|

12.2 Persistence and degradability:

Substance-specific information: |Identification|De|gradability|Biode|gradability| |---|---|---|---|---|

12.2 Persistence and degradability:

|Identification|De|gradability|Biode|gradability| |Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased|BOD5|Not relevant|Concentration|Not relevant| |CAS: Not relevant|COD|Not relevant|Period|28 days| |EC: 701-251-5|BOD5/COD|Not relevant|% Biodegradable|13,4 %|

12.2 Persistence and degradability:

|Identification|De|gradability|Biode|gradability| |Benzenesulfonic acid, C10-16-alkyl derivs., calcium salts|BOD5|Not relevant|Concentration|2 mg/L| |CAS: 68584-23-6|COD|Not relevant|Period|28 days| |EC: 271-529-4|BOD5/COD|Not relevant|% Biodegradable|8 %|

12.3 Bioaccumulative potential

Substance-specific information: |Identification|Bioa|ccumulation potential| |---|---|---|

12.3 Bioaccumulative potential

|Identification|Bioa|ccumulation potential| |Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased|BCF|2| |CAS: Not relevant|Pow Log|9.3| |EC: 701-251-5|Potential|Low|

12.3 Bioaccumulative potential

|Identification|Bioa|ccumulation potential| |Benzenesulfonic acid, C10-16-alkyl derivs., calcium salts|BCF|| |CAS: 68584-23-6|Pow Log|22.12| |EC: 271-529-4|Potential||

Mobility in soil

Identification|Absorpt|ion/desorption||Volatility| |---|---|---|---|---|---| ||Benzenesulfonic acid, C10-16-alkyl derivs., calcium salt|s Koc|831977333|Henry|Not relevant| ||CAS: 68584-23-6|Conclusion|Immobile|Dry soil|Not relevant| ||EC: 271-529-4|Surface tension|Not relevant|Moist soil|Not relevant|

Results of PBT and vPvB assessment:

Product does not meet PBT/vPvB criteria

Product does not meet PBT/vPvB criteria

Endocrine disrupting properties:

Contains Phenol, dodecyl-, branched. A substance shall be considered as having endocrine-disrupting properties that may cause adverse effects on non-target organisms, which is a change in the morphology, physiology, growth, development, reproduction or life span of an organism, system or (sub)population that results in an impairment of functional capacity, an impairment of the capacity to compensate for additional stress or an increase in susceptibility to other influences if: (a) it shows (b) it has an endocrine mode of action, i.e. it alters the function(s) of the endocrine system (c) the adverse effect is a consequence of the endocrine mode of action.

Other adverse effects:

Not described
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consult the authorized waste service manager on the assessment and disposal operations in accordance with Annex 1 and Annex 2 (Directive 2008/98/EC).

Disposal

Consult the authorized waste service manager on the assessment and disposal operations in accordance with Annex 1 and Annex 2 (Directive 2008/98/EC).

Waste Codes

13 08 99* wastes not otherwise specified EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This SDS is an English translation of COMMISSION REGULATION (EU) 2020/878, without any country-specific legislation.

Chemical Safety Assessment Not performed

This product contains Zinc Dialkyl DithioPhosphate (ZDDP), a thermally sensitive substance. Do not reheat above the maximum loading temperature. Higher temperatures can result in exothermic decomposition of the ZDDP leading to the release of highly toxic hydrogen sulphide and possibly extremely odorous alkyl mercaptans.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PXL 5988?

The signal word is no signal word.

What is the physical form of PXL 5988?

PXL 5988 is a liquid appearing as viscous with brown color. It has characteristic odor.

What is the solubility of PXL 5988?

Not relevant *

What is PXL 5988 used for?

Oils

What are the hazard statements for PXL 5988?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of PXL 5988?

The melting point is -13 ºC and the boiling point is >350 ºC.