Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- NYTRO® 4000 X
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- X2C0-V0QM-D001-XK65
Identified Uses
Use in functional fluids - Industrial Use in functional fluids - Professional
Uses advised against
This product must not be used in applications other than those recommended in Section 1, without first seeking the advice of the supplier.
Manufacturers & Suppliers
Nynas AB
manufacturer
Kabyssgatan 4D, 120 30 Stockholm, SWEDEN
+46 8 602 12 00
http://www.nynas.com
Emergency Contacts
Emergency Contact
+44 (0) 1235 239 670
24 hour service
Kemiakuten
020 - 99 60 00
24h service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillate (petroleum), hydrotreated light naphthenic EC: 265-156-6 | 64742-53-6 | 70 - 90% | Yes |
| Distillate (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 30% | Yes |
| Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based EC: 276-738-4 | 72623-87-1 | 30% | Yes |
| 2,6-di-tert-butyl-p-cresol EC: 204-881-4 | 128-37-0 | 0.4% | Yes |
Regulation (EC) No. 1272/2008 [CLP] Annex VI Nota L applies to the base oil(s) in this product. Nota L - The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346.
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. If casualty is unconscious and: If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Maintain an open airway.
Symptoms: breathing is difficult, unconscious, not breathing, breathing is irregular, respiratory arrest
Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Handle with care and dispose of in a safe manner.
Symptoms: skin irritation, swelling or redness
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms: irritation, blurred vision or swelling
If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: unconscious
Immediate Medical Attention
Accidental high pressure injection through the skin requires immediate medical attention. Seek professional medical attention or send the casualty to a hospital. If unconscious, get medical attention immediately.
Medical Treatment
Due to low viscosity there is a risk of aspiration if the product enters the lungs. Treat symptomatically. Always assume that aspiration has occurred.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use direct water jets on the burning product; they could cause splattering and spread the fire. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.
In a fire or if heated, a pressure increase will occur and the container may burst. This substance will float and can be reignited on surface water.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid breathing vapour or mist. Keep non-involved personnel away from the area of spillage. Alert emergency personnel. Except in case of small spillages, the feasibility of any actions should always be assessed and advised, if possible, by a trained, competent person in charge of managing the emergency. Stop leak if safe to do so. Avoid direct contact with the product. Stay upwind/keep distance from source. In case of large spillages, alert occupants in downwind areas.
Normal antistatic working clothes are usually adequate.
Alert occupants in downwind areas. Use full body suit of chemically resistant and thermal resistant material, work gloves, safety helmet, antistatic non-skid safety shoes or boots, goggles and/or face shield.
Water polluting material. May be harmful to the environment if released in large quantities.
Absorb spilled product with suitable non-combustible materials. Transfer collected product and other contaminated materials to suitable containers for recovery or safe disposal.
Materials: suitable non-combustible materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Obtain special instructions before use. Keep away from heat/sparks/open flames/hot surfaces. No smoking. Use and store only outdoors or in a well-ventilated area. Hazard of slipping on spilt product. Avoid release to the environment. Do not ingest. Do not breathe dust/fume/gas/mist/vapours/spray. Avoid contact with eyes, skin and clothing. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Prevent the risk of slipping. Take precautionary measures against static discharge. Avoid splash filling of bulk volumes when handling hot liquid product. Empty containers retain product residue and can be hazardous.
Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.
Ensure that proper housekeeping measures are in place. Contaminated materials should not be allowed to accumulate in the workplaces and should never be kept inside the pockets. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash hands thoroughly after handling. Change contaminated clothes at the end of working shift.
Keep away from heat/sparks/open flames/hot surfaces. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Mechanical ventilation and local exhaust will reduce exposure via the air. Use oil resistant material in construction of handling equipment. Store under recommended conditions and if heated, temperature control equipment should be used to avoid overheating.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. 4 - 8 hours (breakthrough time): nitrile rubber
Recommended: Safety glasses with side shields.
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary.
Wear protective clothing if there is a risk of skin contact. Change contaminated clothes at the end of working shift. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Keep away from extreme heat and oxidizing agents. Take precautionary measures against static discharge.
oxidizing agents
Incomplete combustion is likely to give rise to a complex mixture of airborne solid and liquid particulates, gases, including carbon monoxide, H2S, SOx (sulfur oxides) or sulfuric acid and unidentified organic and inorganic compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The mixture does not contain any substances that are assessed to be a PBT or a vPvB.
12.6 Endocrine disrupting properties
12.7 Other adverse effects
The substance is insoluble in water and may cause physical damage to organisms and impair oxygen transfer if spilled.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recycling of used substance is feasible and recommended. This substance can be burned or incinerated, subject to national/local authorizations, relevant contamination limits, safety regulations and air quality legislation. Disposal can be carried out directly, or by delivery to qualified waste handlers.
Where possible (e.g. in the absence of relevant contamination), recycling of used substance is feasible and recommended. This substance can be burned or incinerated, subject to national/local authorizations, relevant contamination limits, safety regulations and air quality legislation. Contaminated or waste substance (not directly recyclable): Disposal can be carried out directly, or by delivery to qualified waste handlers.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 9006
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
- Transport Class
- 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2020/878
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for NYTRO® 4000 X?
The signal word is danger.
What is the physical form of NYTRO® 4000 X?
NYTRO® 4000 X is a liquid. with light yellow color. It has odourless/light petroleum. odor.
What is NYTRO® 4000 X used for?
Use in functional fluids - Industrial Use in functional fluids - Professional
What are the hazard statements for NYTRO® 4000 X?
This substance has 2 hazard statements:
- H304: May be fatal if swallowed and enters airways.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of NYTRO® 4000 X?
The melting point is -57°C and the boiling point is >250°C (>482°F) [ASTM D 2887].