NextSDS Logo
Safety Data Sheet EN

NYTRO® LYRA X

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NYTRO® LYRA X
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A
UFI Code
BNH1-G0RQ-U00V-R0EN

Identified Uses

Use in functional fluids - Industrial, Use in functional fluids - Professional

Uses advised against

This product must not be used in applications other than those recommended in Section 1, without first seeking the advice of the supplier.

Manufacturers & Suppliers

Nynas AB logo

Nynas AB

manufacturer

Kabyssgatan 4D, 120 30 Stockholm, SWEDEN

+46 8 602 12 00

http://www.nynas.com

N

Nynas Srl

national supplier

Via Bartolomeo d'Alviano, 71/A, 20146 - Milano, Italy

+39 02 607 01 87

Emergency Contacts

Emergency Contact

+44 (0) 1235 239 670

24 hour service

Centro antiveleni - Ospedale Niguarda Cà Granda - Milano

02 66101029

Centro antiveleni - Centro Naz. di Informazione Tossicologica - Pavia

0382 24444

Centro antiveleni - Az. Ospedaliera Papa Giovanni XXII - Bergamo

800883300

Centro antiveleni - Az. Ospedaliera A. Cardarelli - Napoli

081 7472870

Centro antiveleni - Azienda Ospedaliera Careggi - Firenze

055 7947819

Centro antiveleni - Ist. Anestes. e Rianim. Policlinico Gemelli - Roma

06 3054343

Centro antiveleni - Ist. Anestes. e Rianim. Policlinico Umberto I - Roma

06 49978000

Centro antiveleni - Ospedale Pediatrico Bambino Gesù - Roma

06 68593726

Centro antiveleni - Az. Ospedaliera Univ. Foggia - Foggia

0881 732326

Centro antiveleni - Centro antiveleni Veneto - Verona

800.011.858

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P331 Do NOT induce vomiting.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Regulation (EC) No. 1272/2008 [CLP] Annex VI Nota L applies to the base oil(s) in this product. Nota L - The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346.

Chemical Name CAS Number Concentration Hazardous
Distillate (petroleum), hydrotreated light naphthenic EC: 265-156-6 64742-53-6 50% Yes
Distillate (petroleum), hydrotreated light paraffinic EC: 265-158-7 64742-55-8 50% Yes
Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based EC: 276-738-4 72623-87-1 35% Yes
2,6-di-tert-butyl-p-cresol EC: 204-881-4 128-37-0 0.4% Yes

Regulation (EC) No. 1272/2008 [CLP] Annex VI Nota L applies to the base oil(s) in this product. Nota L - The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346.

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. If casualty is unconscious and: If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Get medical attention if adverse health effects persist or are severe. Maintain an open airway.

Symptoms: Inhalation of oil mist or vapours at elevated temperatures may cause respiratory irritation.

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Handle with care and dispose of in a safe manner. Seek medical attention if skin irritation, swelling or redness develops and persists. Accidental high pressure injection through the skin requires immediate medical attention. Do not wait for symptoms to develop.

Symptoms: Adverse symptoms may include the following: irritation dryness cracking

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation, blurred vision or swelling occurs and persists, obtain medical advice from a specialist.

Symptoms: Slight irritant

Ingestion

Always assume that aspiration has occurred. Do not induce vomiting. Can enter lungs and cause damage. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Seek professional medical attention or send the casualty to a hospital. Do not wait for symptoms to develop. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Adverse symptoms may include the following: Nausea or vomiting. diarrhoea

Immediate Medical Attention

Accidental high pressure injection through the skin requires immediate medical attention. Do not wait for symptoms to develop. Seek professional medical attention or send the casualty to a hospital. If unconscious, place in recovery position and get medical attention immediately.

Medical Treatment

Due to low viscosity there is a risk of aspiration if the product enters the lungs. Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use direct water jets on the burning product; they could cause splattering and spread the fire. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst. This substance will float and can be reignited on surface water.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid breathing vapour or mist. Keep non-involved personnel away from the area of spillage. Alert emergency personnel. Stop leak if safe to do so. Avoid direct contact with the product. Stay upwind/keep distance from source. In case of large spillages, alert occupants in downwind areas.

Small spill

Stop leak if without risk. Absorb spilled product with suitable non-combustible materials.

Large spill

Large spillages may be cautiously covered with foam, if available, to limit vapour cloud formation. Do not use water jet. When inside buildings or confined spaces, ensure adequate ventilation. Transfer collected product and other contaminated materials to suitable containers for recovery or safe disposal. Approach the release from upwind.

Environmental

Water polluting material. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Prevent product from entering sewers, rivers or other bodies of water.

Cleanup methods

Absorb spilled product with suitable non-combustible materials. Transfer collected product and other contaminated materials to suitable containers for recovery or safe disposal. Collect the product by skimming or other suitable mechanical means.

Materials: suitable non-combustible materials, foam

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Obtain special instructions before use. Keep away from heat/sparks/open flames/hot surfaces. No smoking. Use and store only outdoors or in a well-ventilated area. Hazard of slipping on spilt product. Avoid release to the environment. Do not ingest. Do not breathe dust/fume/gas/mist/vapours/spray. Avoid contact with eyes, skin and clothing. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Prevent the risk of slipping. Take precautionary measures against static discharge. Avoid splash filling of bulk volumes when handling hot liquid product. Empty containers retain product residue and can be hazardous.

Storage

Store locked up. Protect from sunlight. Keep container tightly closed and sealed until ready for use. Do not store in unlabelled containers. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Ensure that proper housekeeping measures are in place. Contaminated materials should not be allowed to accumulate in the workplaces and should never be kept inside the pockets. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash hands thoroughly after handling. Change contaminated clothes at the end of working shift.

Fire prevention

Keep away from heat/sparks/open flames/hot surfaces. No smoking. Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Mechanical ventilation and local exhaust will reduce exposure via the air. Use oil resistant material in construction of handling equipment. Store under recommended conditions and if heated, temperature control equipment should be used to avoid overheating.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. 4 - 8 hours (breakthrough time): nitrile rubber

Eyes

Recommended: safety glasses with side-shields

Respiratory

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary.

Skin/Body

Wear protective clothing if there is a risk of skin contact. Change contaminated clothes at the end of working shift. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Not applicable.
Softening Point
---
Odor
Odourless/Light petroleum.
Solubility
---
Colour Intensity
---
Form
---
Boiling Point
>230°C (>446°F)
Dynamic Viscosity
---
Melting Point
-48°C
Metal Corrosion
---
Decomposition Temperature
>280°C
Upper Explosive Limit
Not available.
Vapor Pressure
<0,01 kPa (<0,075006 mm Hg)
Odor Threshold
---
Solubility In Fat
---
Flash Point
>140°C (>284°F)
Appearance
---
Ph
Not applicable.
State Under Standard Conditions
---
Solubility In Water
Insoluble in water.
Lower Explosive Limit
Not available.
Freezing Point
-48°C
Flammability
Not available.
Colour
Light yellow
Kinematic Viscosity
9,3 mm²/s (9,3 cSt)
Auto Ignition Temperature
>200°C (>392°F)
Physical State Data
liquid
Solidification Point
---
Bulk Density
---
Evaporation Rate
---
Crystallisation Point
---
Explosive Limits
---
Physical State
Liquid.
Molecular Weight
---
Cloud Point
---
Properties Status
---
Relative Density
---
Vapor Density
Not available.
Relative Evaporation Rate
---
Density
0,87 g/cm³ [15°C (59°F)]
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Keep away from extreme heat and oxidizing agents. Take precautionary measures against static discharge.

Incompatible

Oxidising agent.

Decomposition

Incomplete combustion is likely to give rise to a complex mixture of airborne solid and liquid particulates, gases, including carbon monoxide, H2S, SOx (sulfur oxides) or sulfuric acid and unidentified organic and inorganic compounds.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Recycling of used substance is feasible and recommended. This substance can be burned or incinerated, subject to national/local authorizations, relevant contamination limits, safety regulations and air quality legislation. Contaminated or waste substance (not directly recyclable): Disposal can be carried out directly, or by delivery to qualified waste handlers.

Disposal

Disposal can be carried out directly, or by delivery to qualified waste handlers.

Waste Codes

13 03 07* mineral-based non-chlorinated insulating and heat transmission oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
9006
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (2,6-di-tert-butyl-p-cresol)
Transport Class
9
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessments for all substances in this product are either Complete or Not applicable.

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NYTRO® LYRA X?

The signal word is danger.

What is the physical form of NYTRO® LYRA X?

NYTRO® LYRA X is a liquid. with light yellow color. It has odourless/light petroleum. odor.

What is NYTRO® LYRA X used for?

Use in functional fluids - Industrial, Use in functional fluids - Professional

What are the hazard statements for NYTRO® LYRA X?

This substance has 2 hazard statements:

  • H304: May be fatal if swallowed and enters airways.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of NYTRO® LYRA X?

The melting point is -48°C and the boiling point is >230°C (>446°F).