NextSDS Logo
Safety Data Sheet EN

VALONA MS 7023 HC

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
VALONA MS 7023 HC
Product Code
082183

Regulatory Identifiers

CAS Number
N/A

Identified Uses

neat metalworking oil

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'ile 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

T

TotalEnergies Marketing Asia-Pacific Middle East Pte. Ltd.

distributor

182 Cecil Street #27-01 Frasers Tower Singapore 069547

+65 6879 2200

Emergency Contacts

Asia-Pacific

+65 3158 1074

Middle-East

+44 1235 239671

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1B

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P261 Avoid breathing gas, vapor or spray.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P333 + P313 If skin irritation or rash occurs: Get medical advice or attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated light paraffinic 64742-55-8 10 - 25% No
Polysulfides, di-tert-dodecyl 68425-15-0 5% No

Mineral oil of petroleum origin Product DMSO extract as measured by IP 346|containing minera|l oil with less than 3%

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards. No specific data.

Skin contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Defatting to the skin. May cause skin dryness and irritation. May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness, dryness, cracking.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No known significant effects or critical hazards. No specific data.

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards. No specific data.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical,CO₂,water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Hydrocarbon-proof gloves, Fluorinated rubber, nitrile rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
limpid
Colour
Yellow.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
Technically not possible to measure
Boiling Point
>316°C (>600.8°F) [EN ISO 3405]
Flash Point
Open cup: 200°C (392°F) [Cleveland Open Cup (COC)]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
<0.013 kPa (<0.1 mm Hg) [room temperature]
Vapor Density
>2 [Air = 1]
Relative Density
0.85 [ISO 12185]
Bulk Density
---
Density
0.85 g/cm³ [15°C] [ISO 12185]
Flammability
---
Upper Explosive Limit
7%
Lower Explosive Limit
0.9%
Explosive Limits
---
Auto Ignition Temperature
>200°C (>392°F) [ASTM E 659]
Decomposition Temperature
Not applicable.
Solubility
---
Partition Coefficient
Not applicable.
Solubility In Water
Not soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C (104°F)): 21 mm²/s (21 cSt) [ISO 3104]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Incompatible

Strong oxidizing agents

Decomposition

carbon monoxide carbon dioxide nitrogen oxides phosphorus oxides sulfur oxides Hydrogen sulfide Mercaptans Zinc oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Distillates (petroleum), hydrotreated light paraffinic / Polysulfides, di-tert-dodecyl: Acute EC50 >100 mg/l (Algae - Pseudokirchnerella subcapitata, 72 hours, OECD 201); Acute EC50 >10000 mg/l (Daphnia - Daphnia magna, 48 hours, OECD 202); Chronic NOELR 10 mg/l (Daphnia - Daphnia magna, 21 days, OECD 211); Chronic NOELR >1000 mg/l (Fish - Oncorhynchus mykiss, 21 days); Acute LC50 100.1 mg/l (Fish, 96 hours); Chronic NOEC >100 mg/l (Algae - Pseudokirchneriella subcapitata, 72 days, OECD 201)

Bioaccumulative potential

|**Bioaccumulative potential**||||| |**Product/substance**|**LogKow**|**BCF**|**Potential**|| |Polysulfides, di-tert-dodecyl|>12|-|high||

Mobility in soil

Not available. Given its physical and chemical characteristics, the product generally shows low soil mobility. The product is insoluble and floats on water. Forms an emulsion. Loss by evaporation is limited.

Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Incineration or landfill should only be considered when recycling is not feasible.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The information stated in this section relates solely to the conformity of the chemical product with the countries Inventories. The information used to confirm the inventory status of this product may be based on additional data to the chemical composition shown in Section 3. Other regulations may apply for importation or marketing authorizations.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for VALONA MS 7023 HC?

The signal word is warning.

What is the physical form of VALONA MS 7023 HC?

VALONA MS 7023 HC is a liquid. appearing as limpid with yellow. color. It has characteristic. odor.

What is VALONA MS 7023 HC used for?

neat metalworking oil

What are the hazard statements for VALONA MS 7023 HC?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of VALONA MS 7023 HC?

The melting point is Technically not possible to measure and the boiling point is >316°C (>600.8°F) [EN ISO 3405].