NextSDS Logo
Safety Data Sheet EN

SPECTRASYN ELITE™ 65

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SPECTRASYN ELITE™ 65

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Base oil

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

E

ExxonMobil Petroleum & Chemical BV on behalf of MOBIL CHEMICAL PRODUCTS INTERNATIONAL INC.

manufacturer

SYNTHETICS DEPARTMENT HERMESLAAN 2 B-1831 MACHELEN Belgium

+32-2-239 3111

Emergency Contacts

CHEMTREC

+(44)-8708200418

24 Hour

National Poison Control Centre

111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No Hazardous Substance(s) required for disclosure.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Symptoms: minimal or absent (initial symptoms from high pressure injection)

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required. Seek medical attention if discomfort occurs.

Symptoms: discomfort

Immediate Medical Attention

If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Medical Treatment

Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury for high pressure injection.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled material. Additional protective measures may be necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders.

Small spill

Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.

Materials: suitable absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance.

Storage

Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present. Use proper bonding and/or earthing procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use. If product is hot, thermally protective, chemical resistant gloves are recommended. If contact with forearms is likely, wear gauntlet style gloves.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact. If product is hot, thermally protective, chemical resistant apron and long sleeves are recommended.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear
Colour
Colourless
Colour Intensity
---
Form
Clear
Odor
Odourless
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
>230°C (446°F) [ASTM D-93]
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C [In-house method]
Vapor Density
---
Relative Density
0.85 [ASTM D4052]
Bulk Density
---
Density
---
Flammability
Not technically feasible
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
water Negligible
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
615 cSt (615 mm2/sec) at 40°C | 65 cSt (65 mm2/sec) at 100°C [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. TOXICITY

Material -- Not expected to be harmful to aquatic organisms.

12.2. PERSISTENCE AND DEGRADABILITY

Biodegradation: Material -- Expected to biodegrade slowly.

12.3. BIOACCUMULATIVE POTENTIAL

Not determined.

12.4. MOBILITY IN SOIL

Not determined.

12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)

Material does not meet the Reach Annex XIII criteria for PBT or vPvB.

Material does not meet the Reach Annex XIII criteria for PBT or vPvB.

12.6. OTHER ADVERSE EFFECTS

No adverse effects are expected.

No adverse effects are expected.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Waste Codes

13 02 06* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Applicable UK legislation: REACH, CLP

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SPECTRASYN ELITE™ 65?

The signal word is no signal word.

What is the physical form of SPECTRASYN ELITE™ 65?

SPECTRASYN ELITE™ 65 is a liquid appearing as clear with colourless color. It has odourless odor.

What is the solubility of SPECTRASYN ELITE™ 65?

water Negligible

What is SPECTRASYN ELITE™ 65 used for?

Base oil

What is the melting point of SPECTRASYN ELITE™ 65?

The melting point is No data available and the boiling point is No data available.